THE AGL ENGINEERING CENTRE by Precision AGL Academy · Performance & Verification

AGL Photometric Testing Guide

The practical field guide to verifying that runway, taxiway, approach and PAPI lighting delivers the required intensity, distribution, colour and alignment — equipment, field measurement, evaluation, reporting and troubleshooting.

Overview

What Is AGL Photometry?

The measurement and evaluation of the photometric performance of Airfield Ground Lighting systems.

AGL photometry verifies whether installed runway, taxiway, approach and PAPI lighting provides the required light intensity, distribution, colour and alignment for its operational function. It is carried out during commissioning, periodic inspection, maintenance, rehabilitation, troubleshooting and performance verification. A properly planned inspection helps identify degraded light output, incorrect beam alignment, colour deviations, optical contamination and installation problems that can affect the visual aids pilots rely on.

The objective is not simply to determine whether a light is ON or OFF. A fixture can operate electrically and still fail photometrically — through optical degradation, incorrect aiming, contamination, damaged lenses or filters, incorrect installation, lamp or LED degradation, mechanical movement, incorrect transformer or circuit conditions, or measurement setup errors.

Electrical Serviceability

Does the fixture light up and carry current correctly?

Photometric Serviceability

Does the light deliver the required intensity, distribution, colour and alignment?

Two Different Checks

Electrical serviceability and photometric serviceability are different aspects of AGL inspection.

New to the topic? This page is the practical field guide. For the concepts — candela vs lux, isocandela diagrams and what photometry measures — start with AGL Photometry.

Light intensityIntensity distributionBeam coverageBeam alignmentColourVertical / horizontal angular performancePhotometric uniformityOutput at specified test points
THE DIAGRAM · ANGLE GRID curves of equal candela around the beam axis READING IT · BANDS AND SPACING between two curves, close or wide apart 50 % OF PEAK 10 % OF PEAK LEFT RIGHT UP HORIZONTAL AND VERTICAL ANGLE FROM THE BEAM AXIS P 1 2 3 4 PEAK 50 % 10 % P LIES BETWEEN 10 % AND 50 % OF PEAK read from the two curves around it 6 CLOSE steep fall WIDE gentle fall 5 1ANGLE GRIDhorizontal across, vertical up, beam axis at centre 2CURVE OF EQUAL CANDELAevery direction on it has the same intensity 3PEAK ON THE AXIShighest intensity, centre of the rings 4READ A DIRECTIONfind its angles, see the two curves around it 5CURVE SPACINGclose curves mean a quick change in intensity 6COMPARE WITH THE STANDARDmeasured against the required diagram CORRECT READINGBY ANGLE, THEN BETWEEN TWO CURVESDirection in, intensity band out WRONG READINGTHE PEAK VALUE ONLYSame peak, very different beams SCHEMATIC · ILLUSTRATIVE LEVELS · NOT A STANDARD DIAGRAM · SEE ICAO ANNEX 14 VOL. I, APP. 2
Figure 1. An isocandela diagram: curves join directions of equal intensity on a grid of horizontal and vertical angle.AGL Visual Encyclopedia: What is an isocandela diagram?
Purpose

Why Is Photometric Testing Required?

Objective evidence that the installed system continues to perform to the applicable design and acceptance requirements.

New Installation

Verify performance of newly installed lighting before commissioning and operational acceptance.

Commissioning

Establish that the completed installation meets the specified photometric requirements.

Periodic Inspection

Identify deterioration in lighting performance over time.

Preventive Maintenance

Verify performance after maintenance activities and component replacement.

Rehabilitation

Establish the condition of existing lighting before and after rehabilitation work.

Troubleshooting

Investigate abnormal performance, uneven brightness, incorrect beam coverage or alignment problems.

Airport audits and acceptance. Photometric measurements can form part of technical inspection, acceptance documentation and airport lighting performance records.

Equipment

AGL Photometric Testing Equipment

A professional survey needs suitable, calibrated equipment configured for the lighting facility under test.

Airport Photometer

Measures photometric performance of airfield lighting — intensity, angular distribution, colour, beam characteristics and values at defined positions. It should suit the type of AGL facility under test.

Runway Photometer

Used for runway edge, threshold, end, centreline, touchdown zone and approach lighting. The arrangement must correspond to the applicable test geometry and requirements.

PAPI Photometer

Evaluates PAPI optical characteristics: intensity, beam coverage and alignment, colour transition, vertical angular characteristics and horizontal coverage. Highly sensitive to geometry and alignment.

Measurement System

  • Photometer and light sensor
  • Positioning system and measurement frame
  • Angular measurement arrangement
  • Data acquisition equipment and software
  • Reference targets or alignment aids
  • Calibration documentation
Pre-survey verificationWhat to confirm
CalibrationInstrument identification, calibration validity, traceable certificate
Instrument conditionSensor condition, battery condition, zero/reference condition where applicable
ConfigurationMeasurement configuration, software and settings
A photometric result is only meaningful when the measurement system itself is controlled. Calibrate in accordance with the manufacturer's requirements and the applicable inspection procedure.
PHOTOMETER ARRANGEMENT · SIDE VIEW · SCHEMATICDARK ROOMBAFFLESdTEST DISTANCEFIXTURE ROTATES · PHOTOMETER STAYS FIXED123451FIXTURE ON STAGERotates to each test angle2BEAM AXISAimed at the photometer3TEST DISTANCELong enough for a point source4PHOTOMETERFixed detector reads the light5STRAY LIGHT CONTROLDark room and bafflesSCHEMATIC · PROPORTIONS ARE ILLUSTRATIVE, NOT A TEST SETUP DRAWING
Figure 2. Photometer arrangement: fixture, rotating stage and photometer set out so intensity can be read at each angle.AGL Visual Encyclopedia: What is a photometer arrangement?
Setup

Measurement Frame & Sensor Positioning

The physical position and orientation of the sensor are critical.

Errors in sensor height, distance, horizontal position, vertical angle, azimuth, fixture orientation or reference point can produce incorrect photometric results.

Establish the measurement setup before testing and keep it consistent throughout the survey.

MEASUREMENT GRID · ANGLE vs ANGLEHORIZONTAL ANGLEVERTICAL ANGLEBEAM AXIS POINTcd READINGSTEP123451BEAM AXIS POINTCentre of the grid2MEASUREMENT POINTOne angle, one reading3GRID STEPAngular spacing of points4COVERAGEExtends past the beam edge5TABLE OF VALUESReadings form the resultsSCHEMATIC · SPACING AND EXTENT ARE ILLUSTRATIVE, NOT STANDARD VALUES
Figure 3. The photometric grid: angular points at which intensity is read so a whole beam is described by a table.AGL Visual Encyclopedia: What is a photometric grid?
Runway Lighting

Runway Light Photometry

Each runway lighting facility has its own operational function and photometric characteristics.

FacilityWhat is verifiedNotes
Runway edge lightsIntensity, beam distribution, colour, orientation, fixture condition, uniformity between test pointsProvide lateral guidance and define the usable runway edges
Threshold lightsRequired colour, intensity, angular coverage, alignment, individual fixture performance
Runway end lightsRequired colour, intensity, beam coverage, alignment, fixture condition
Centreline lightsRelevant intensity and distribution characteristics where installedParticularly important for precision approach runways and enhanced visual guidance
Touchdown zone lightsEvaluated per the applicable photometric arrangement and measurement requirements
Approach lightingIntensity, distribution, alignment, colour, system configuration, individual light performanceMultiple unit types and configurations
Taxiway Lighting

Taxiway Photometry

Taxiway lighting provides visual guidance for aircraft ground movement.

Taxiway Edge Lights

  • Intensity
  • Colour
  • Beam distribution
  • Alignment
  • Fixture condition

Taxiway Centreline Lights

Where installed, evaluated for specified photometric performance and colour characteristics.

Stop Bars

A critical visual aid associated with runway entry control.

  • Intensity and colour
  • Beam coverage
  • Individual fixture performance
  • Circuit operation

Runway Guard Lights

  • Correct operation
  • Intensity and colour
  • Flashing characteristics where applicable
  • Alignment and visibility

Photometric inspection should be considered together with the operational function of the lighting facility.

Visual Approach Slope

PAPI Photometry

Its photometric performance is closely tied to the accuracy of the visual glide-path indication given to the pilot.

Intensity

Verify the PAPI light units produce the required light output.

Beam Coverage

The beam should provide the required horizontal and vertical coverage.

Beam Alignment

Each unit's angular position is critical — guidance relies on the relationship between the red and white portions of the beam.

Colour

The white-to-red transition must be clearly defined and within applicable requirements.

Vertical Angle

Vertical angular characteristics of each unit are a key part of performance verification.

Geometry

Measurement geometry matters as much as the readings themselves.

PAPI photometry is not simply an intensity test. Measurement geometry, beam alignment and colour transition are equally important.

PAPI WING BAR · SIDE VIEW OF THE FOUR TRANSITION ANGLES 2°30′2°50′3°10′3°30′ 3°00′ ABOVE SLOPE · WHITE BELOW SLOPE · RED RUNWAY 21345 1Electrical checks2Elevation angle: inclinometer3Azimuth aiming along runway4Colour + sharp transition5Flight inspection SCHEMATIC · ANGLES EXAGGERATED, NOT TO SCALE · HIGHEST SETTING IS THE UNIT NEAREST THE RUNWAY
Figure 4. How a PAPI is tested: five checks for soundness, angle, aim and the colour change point.AGL Visual Encyclopedia: How is a PAPI tested?
Procedure

The AGL Photometry Procedure

A structured procedure gives repeatable, traceable results.

1. Preparation

Review the test requirement; identify the lighting facilities to be tested; review drawings, runway/taxiway configuration and previous photometric reports; prepare test forms; verify equipment and calibration status; coordinate with airport operations and ATC as required.

2. Calibration verification

Verify photometer ID, certificate and validity, sensor condition, power supply, software and settings. Record equipment details in the report.

3. System inspection

Visually check for damaged fixtures, dirty lenses, broken components, incorrect orientation, loose fittings, obstructions, water ingress, cable or connector issues, transformer issues and abnormal light output — separating physical problems from true photometric deficiencies.

4. Measurement setup

Confirm reference point, distance, sensor height and orientation, horizontal and vertical position, angle and fixture identification. Keep the method consistent.

5. Field measurement

Operate at the required condition and record at selected units, defined points, CCR intensity steps and angular positions. Each measurement must be traceable to its location.

6. Data evaluation

Compare against applicable requirements: intensity, distribution, colour, alignment, coverage, uniformity. Do not fail a fixture merely because it looks dim.

7. Failure identification

Identify the probable cause: degradation, contamination, aiming, optical damage, LED/lamp, transformer, connector, cable, CCR output, installation error or measurement error.

8. Rectification

Clean, realign, replace fixture or optical parts, replace transformer, repair connector or cable, investigate the CCR, correct mechanical faults.

9. Retest

Repeat the relevant measurement to confirm the problem is resolved and the requirement is now met.

10. Final report

Issue a complete, traceable report: project and airport/runway details, test date, weather/visibility where relevant, equipment and calibration information, methodology, measurement locations, raw and evaluated results, pass/fail status, deficiencies, corrective actions, retest results, photographs, test personnel and approval/sign-off.

PHOTOMETRIC TESTING PROCESS · SEVEN STEPS, FROM MOUNTING TO REPORT 1 PREPARE Identify & mount 2 ALIGN Axis & centre 3 STABILISE Rated current 4 SCAN Grid, angle by angle 5 CHECK Repeat reference 6 RECORD Data table 7 REPORT Isocandela & report STEP 4 · SCANNING THE MEASUREMENT GRID · ONE READING PER GRID POINT HORIZONTAL ANGLE → VERTICAL ANGLE → INTENSITY TABLE H 0 / V 0 1850 cd H 2 / V 0 1420 cd H 0 / V 2 1610 cd H 2 / V 2 1180 cd EXAMPLE VALUES ONLY ISOCANDELA DIAGRAM & PHOTOMETRIC REPORT REPEAT A REFERENCE READING DURING AND AFTER THE SCAN DRIFT FOUND → REPEAT THAT PART, DO NOT REPORT IT RING = FINER SPACING NEAR THE PEAK COLOUR ALSO MEASURED FOR COLOURED LIGHTS SCHEMATIC · EXAMPLE VALUES ONLY · LIMITS FOLLOW THE STANDARD AND LABORATORY PROCEDURE
Figure 5. The photometric testing sequence: prepare, align, stabilise, scan the grid, check, record and report.AGL Visual Encyclopedia: What is the photometric testing process?
Failure Modes

Common AGL Photometry Failures

Tap a card to see possible causes.

Low intensity

Possible causes

  • Lamp / LED degradation
  • Optical contamination
  • Damaged lens
  • Incorrect CCR setting
  • Transformer problem
  • Electrical supply issue
  • Fixture degradation

Incorrect colour

Possible causes

  • Damaged colour filter
  • Optical degradation
  • Incorrect light source
  • Fixture contamination
  • Measurement equipment issue

Poor alignment

Possible causes

  • Mechanical movement
  • Incorrect installation
  • Damaged mounting
  • Maintenance error
  • Settlement of supporting structure

Damaged optical system

Possible causes

  • Cracked lens
  • Damaged filter
  • Clouded optical window
  • Water contamination
  • Internal optical damage

Contamination

Possible causes

  • Dirt and dust
  • Oil
  • Moisture

Incorrect installation

Possible causes

  • Fixture height
  • Orientation and position
  • Aiming
  • Spacing / geometry

Sensor positioning error

Possible causes

  • Incorrect distance
  • Incorrect sensor height
  • Incorrect angle
  • Incorrect reference point
  • Sensor misalignment

Obstruction & interference

Possible causes

  • Temporary obstructions
  • Permanent obstructions
  • Surrounding environment

Wiring & transformer issues

Possible causes

  • Series circuit
  • Isolating transformer
  • Primary / secondary connector
  • Cable
  • CCR
  • Fixture connections
Alignment: a fixture may produce adequate intensity and still fail because its beam is incorrectly aimed.
System View

Photometry and the AGL Electrical Chain

Photometry should never be considered independently from the electrical system.

CCR
Primary Cable
Primary Connector
Isolating Transformer
Secondary Connector
Light Fixture

A photometric deficiency may require investigation across the complete chain. For low light intensity, work from the fixture back: fixture condition → optical system → secondary connection → isolating transformer → primary circuit → CCR output. This avoids replacing a fixture when the real problem is elsewhere in the series circuit.

Documentation

The Photometric Report

Enough information for another engineer to understand what was done, and why.

A professional report answers: What was tested? How? With what equipment? Where were measurements taken? What values were measured? Which requirement applied? Which points failed? What corrective action was taken? What were the retest results?

Report sections
1. Cover page8. Measurement geometry15. Photographs
2. Project information9. Lighting system configuration16. Conclusion
3. Scope of testing10. Measurement results17. Test personnel
4. Applicable standards11. Pass/fail evaluation18. Approval / signatures
5. Test equipment12. Deficiency register19. Calibration certificates
6. Calibration details13. Corrective actions20. Supporting drawings
7. Test methodology14. Retest results
AirportRunway / taxiwayLighting facilityFixture IDMeasurement locationTest date & conditionWeather / visibility (where relevant)Photometer IDAcceptance criteriaPass / failDeficienciesRetest results
PHOTOMETRIC REPORT · SIX THINGS TO READ, IN ORDER 1 IDENTIFY What was tested 2 CONDITIONS Current, distance 3 DATA Table & isocandela 4 COMPARE Against requirement 5 COLOUR Chromaticity 6 CONCLUDE Result & limits EXAMPLE REPORT SHEET · READ AGAINST THE REQUIREMENT, NOT ON ITS OWN 1 FIXTURE · SOURCE · COLOUR · LABORATORY · DATE 2 RATED CURRENT · TEST DISTANCE · STANDARD USED 3 ISOCANDELA DIAGRAM · DASHED BOX = REQUIRED AREA 5 CHROMATICITY x, y inside the colour limits 4 POINT-BY-POINT COMPARISON POINT REQUIRED MIN MEASURED RESULT A (0, 0) 1500 cd 1850 cd PASS B (+2, 0) 1000 cd 1120 cd PASS C (-2, 0) 1000 cd 960 cd FAIL D (0, +1) 800 cd 880 cd PASS ONE POINT BELOW ITS LIMIT IS A FAILURE · EXAMPLE VALUES ONLY 6 RESULT APPLIES TO THE TESTED SAMPLE UNDER STATED CONDITIONS SCHEMATIC · EXAMPLE VALUES ONLY · REQUIRED POINTS AND LIMITS COME FROM THE APPLICABLE STANDARD
Figure 6. Reading a photometric report: what was tested, what was measured and whether it meets the requirement.AGL Visual Encyclopedia: How do you read a photometric report?
Traceability

AGL Photometry Documentation

Good photometry is not only about measurement — it is also about traceability.

What & where

  • Airport
  • Runway / taxiway
  • Lighting facility
  • Fixture identification
  • Measurement location

How & with what

  • Test date and test condition
  • Photometer identification
  • Calibration information

Results & action

  • Measured values
  • Acceptance criteria
  • Pass / fail status
  • Deficiencies and corrective actions
  • Retest results

Keep the history. Historical records help identify gradual degradation and recurring problems — a single result tells you the condition today; a series of results tells you the trend.

Maintenance

Photometry During AGL Maintenance

Verify that maintenance restored intended performance — not just electrical operation.

Inspect
Clean
Adjust
Measure
Evaluate
Rectify
Retest
Record

Photometric testing is especially useful after fixture replacement, major AGL maintenance, runway or taxiway rehabilitation, PAPI adjustment, approach lighting maintenance, significant pavement works, fixture realignment and lighting system modification.

Comparison

Photometry vs Visual Inspection

They serve different purposes.

CheckVisual inspectionPhotometric testing
Light ON / OFFYesYes
Physical damageYesMay identify effect
Lens contaminationYesYes
Light intensitySubjectiveMeasured
Beam alignmentLimitedMeasured
ColourVisual indicationMeasured / evaluated
Beam distributionLimitedMeasured
Performance verificationLimitedYes
Numerical test resultsNoYes
Trend monitoringLimitedYes
A light that appears normal during visual inspection may still require photometric verification.
Operating Condition

Photometric Testing at Different CCR Intensity Steps

Verification should consider the applicable test condition for the facility and measurement requirement.

AGL systems operate at different intensity steps through the Constant Current Regulator (CCR). The purpose is to establish whether the system delivers the required performance under the specified operating condition.

When investigating abnormal results, comparing performance across CCR steps can reveal fixture response problems, circuit abnormalities, transformer issues, CCR-related issues and non-linear or abnormal light output.

Troubleshooting

Photometry Troubleshooting Approach

When a measurement fails, avoid immediately replacing the fixture.

1. Confirm the measurement

Equipment, calibration, sensor position, measurement geometry and test settings.

2. Inspect the fixture

Lens, optical components, cleanliness, alignment, mechanical condition.

3. Check the secondary circuit

Secondary connector, transformer, fixture connection.

4. Check the primary circuit

Primary connector, cable, series circuit.

5. Check the CCR

Output current, intensity step, circuit condition, monitoring indications.

6. Repeat the measurement

After corrective action, perform a controlled retest.

Standards

AGL Photometry Standards & References

Always evaluate against the applicable edition and specific facility requirements — not generic numerical values.

ICAO

Annex 14, Volume I; Airport Design Manual; applicable guidance on visual aids.

FAA

Requirements for airport lighting and visual aids.

National

Applicable national aviation authority requirements.

Project

Airport technical specifications, project specifications, manufacturer documentation and approved design drawings.

Important: acceptance values, test geometry and measurement methods vary by lighting facility, operational category, applicable standard and project specification. Always use the controlled project reference for the installation under test.

Workflow

AGL Photometry Workflow

From plan to traceable report.

Plan
Prepare
Inspect
Set Up
Measure
Evaluate
Identify
Rectify
Retest
Report
StageWhat happens
PlanDefine scope, facilities, test conditions and acceptance requirements
PrepareVerify equipment, calibration, drawings and safety/operational coordination
InspectCheck the physical condition of the lighting system
Set UpEstablish the correct measurement geometry and sensor position
MeasureRecord photometric data systematically
EvaluateCompare results with the applicable requirements
IdentifyLocate failed or abnormal lighting points
RectifyCorrect the underlying problem
RetestVerify the effectiveness of the corrective action
ReportIssue a complete and traceable photometric report
Field Checklist

Photometry Field Checklist

Tap to tick items off as you work through a survey.

Plan & Prepare

Define scope, facilities, test conditions and acceptance requirements
Review drawings and previous reports
Coordinate with airport operations / ATC
0 / 3 complete

Verify & Set Up

Check photometer calibration and validity
Visually inspect the lighting system
Establish measurement geometry and sensor position
0 / 3 complete

Measure & Evaluate

Record measurements traceable to location
Compare with applicable requirements
Identify failed or abnormal points
0 / 3 complete

Rectify & Report

Carry out corrective action
Retest after rectification
Issue the traceable photometric report
0 / 3 complete
Key Principles

8 Key Principles of AGL Photometry

01 — A light being ON does not prove photometric compliance.

Electrical operation and photometric performance are different checks.

02 — Measurement geometry matters.

Incorrect sensor position can produce incorrect results.

03 — Calibration matters.

Measurements need controlled, traceable equipment.

04 — Alignment matters.

A working fixture can still give incorrect visual guidance if misaligned.

05 — Colour matters.

Intensity alone does not establish complete photometric performance.

06 — Troubleshoot the complete circuit.

The cause may be upstream of the fixture.

07 — Always retest after rectification.

A repair should be verified by measurement.

08 — Record everything.

Data is valuable when traceable and comparable over time.

Measure correctly. Evaluate objectively.

Rectify systematically. Retest and record. Photometry is a complete engineering verification process — equipment, geometry, configuration, electrical systems, optical performance, alignment, colour, evaluation and corrective action.

AGL Engineering Hub

Explore the AGL Engineering Knowledge Hub

Fundamentals

Standards & Compliance

Runway, Taxiway & Approach Lighting

Surface Movement & Safety

PAPI

Electrical Engineering & Power

Photometry & Testing

Maintenance, Inspection & Safety

Resources, Documentation & Careers

FAQ

Frequently Asked Questions

Q1What is AGL photometry?

AGL photometry is the measurement and evaluation of the photometric performance of Airfield Ground Lighting systems, including intensity, distribution, colour and alignment as applicable.

Q2What is an airport photometer?

An airport photometer is a measurement instrument designed or configured to measure the photometric performance of airport visual aids and lighting systems.

Q3What is a runway photometer?

A runway photometer measures the photometric characteristics of runway lighting facilities such as edge, threshold, centreline and other applicable runway lights.

Q4What is PAPI photometry?

PAPI photometry is the measurement and evaluation of the optical performance of a PAPI system, including intensity, beam coverage, colour and angular characteristics.

Q5How is runway lighting tested?

Using a defined measurement procedure and suitable photometric equipment. The measurement geometry, test points and acceptance criteria depend on the particular runway lighting facility and applicable requirements.

Q6How is taxiway lighting tested?

By measuring the applicable photometric characteristics of taxiway edge, centreline, stop bar, runway guard and other installed lighting facilities.

Q7Why is runway light intensity testing important?

It provides objective evidence that the lighting system produces the required visual guidance performance under the specified test conditions.

Q8Can a light pass visual inspection but fail photometry?

Yes. A fixture may appear operational while producing inadequate intensity, incorrect beam distribution, incorrect colour or incorrect alignment.

Q9How often should AGL photometry be carried out?

The required frequency depends on the applicable aviation authority requirements, airport procedures, project specifications, operational requirements and the maintenance programme.

Q10Is photometry required after AGL maintenance?

Where specified by the maintenance procedure or applicable requirements, photometric verification can confirm that the lighting system still meets its required performance after maintenance or adjustment.

Q11What causes low AGL light intensity?

Potential causes include optical contamination, lamp or LED degradation, damaged optical components, incorrect CCR output, transformer problems, connector or cable issues, fixture degradation or measurement errors.

Q12What causes PAPI photometric failure?

Possible causes include incorrect unit alignment, optical degradation, contamination, damaged components, incorrect measurement geometry or other system configuration issues.

Q13What information should an AGL photometric report contain?

Project details, scope, equipment and calibration information, measurement methodology, test geometry, measured results, acceptance criteria, deficiencies, corrective actions, retest results and supporting records.

Go Deeper

Calculators & Tools

Work with real photometric data.

CALCULATOR

Photometric Test Data Analyzer

Open →
CALCULATOR

Runway Light Photometry Reference

Open →
CALCULATOR

AGL Photometric Intensity Calculator

Open →
CALCULATOR

PAPI Indication Reference

Open →
EQUIPMENT

Photometer

Open →
EQUIPMENT

Goniophotometer

Open →
Compare

Comparisons

Common photometry questions, side by side.

COMPARISON

Photometry vs Visual Inspection

Open →
COMPARISON

Photometric vs Electrical Compliance

Open →
COMPARISON

Laboratory vs Field Photometry

Open →
COMPARISON

Goniophotometer vs Lux Meter

Open →
COMPARISON

Fixture Alignment vs Photometric Performance

Open →
COMPARISON

New Fixture vs In-Service Photometry

Open →
Apply It

SOPs, Forms & Checklists

Procedures, forms and inspection checklists for photometric work.

SOP

Division 17: Testing & Photometry

Open →
FORMS

Division 15: Photometry & Optical Testing

Open →
INSPECTION

Division 20: Testing, Photometry & Calibration

Open →
COMMISSIONING

Division 16: AGL Photometry Testing

Open →
FAILURES

Division 18: AGL Photometry Failures

Open →
ARTICLE

SOP for AGL Photometry Testing

Open →
ARTICLE

How Often Is AGL Photometry Performed?

Open →
CONCEPTS

AGL Photometry (Concept Guide)

Open →
CAREER

Photometry Career Questions

Open →
Related Guides

Related AGL Engineering Guides

Explore related technical subjects.

GUIDE

AGL Design & Electrical Engineering

Open →
GUIDE

PAPI Engineering Guide

Open →
GUIDE

AGL Testing & Inspection

Open →
STANDARDS

ICAO Annex 14 AGL Requirements

Open →
STANDARDS

FAA AC 150/5340 Series Explained

Open →
STANDARDS

Standards Companion

Open →
Runway Lighting SystemsTaxiway Lighting SystemsApproach Lighting SystemsAGL Installation & CommissioningAGL Cables & Connector EngineeringConstant Current RegulatorsAGL Isolating TransformersAGL Troubleshooting Guide
Field Insight

Engineering & Expert Notes

Electrical Health Is Not Optical Performance
Principle

Fixtures can draw correct current while delivering poor intensity or colour. Photometric checks confirm what the pilot actually sees.

Calibrate and Document the Measurement Setup
Equipment

Record instrument identity, calibration status and sensor position. Results are only credible when the setup can be reproduced.

Control Ambient Light and Surface Conditions
Conditions

Stray light and contamination affect readings. Choose suitable conditions and clean optics before measurement, noting what was done.

Alignment Errors Can Look Like Low Intensity
Alignment

Check aiming before concluding that a unit is under-performing. A correctly aimed unit may measure very differently from a misaligned one.

Trend Results Against a Baseline
Trending

Compare each measurement with commissioning data. Gradual change is easier to see and act on than a single reading.

Report What Was Measured and How
Reporting

Include method, location, conditions and instrument details so another engineer could understand and repeat the test.

Precision AGL Academy

Understand AGL. Build Your Engineering Skills.

You now understand how photometry verifies AGL performance — intensity, distribution, colour and alignment measured against design requirements.

Take the next step with Precision AGL Academy.

Learn AGL Step by Step

Build your knowledge through structured technical learning covering:

AGL Fundamentals Components Electrical Systems Design Photometry Testing Troubleshooting Maintenance

Move from understanding how AGL works to developing the practical knowledge needed to analyse, operate and maintain complete AGL systems.

Understand the system. Build the knowledge. Apply the engineering.