What is the photometric testing process?

The sequence by which a fixture is measured in the laboratory: prepare, align, stabilise, scan the grid, check, record and report.

PHOTOMETRIC TESTING PROCESS · SEVEN STEPS, FROM MOUNTING TO REPORT 1 PREPARE Identify & mount 2 ALIGN Axis & centre 3 STABILISE Rated current 4 SCAN Grid, angle by angle 5 CHECK Repeat reference 6 RECORD Data table 7 REPORT Isocandela & report STEP 4 · SCANNING THE MEASUREMENT GRID · ONE READING PER GRID POINT HORIZONTAL ANGLE → VERTICAL ANGLE → INTENSITY TABLE H 0 / V 0 1850 cd H 2 / V 0 1420 cd H 0 / V 2 1610 cd H 2 / V 2 1180 cd EXAMPLE VALUES ONLY ISOCANDELA DIAGRAM & PHOTOMETRIC REPORT REPEAT A REFERENCE READING DURING AND AFTER THE SCAN DRIFT FOUND → REPEAT THAT PART, DO NOT REPORT IT RING = FINER SPACING NEAR THE PEAK COLOUR ALSO MEASURED · WHITE INCLUDED SCHEMATIC · EXAMPLE VALUES ONLY · LIMITS FOLLOW THE STANDARD AND LABORATORY PROCEDURE
scan path over the grid
set-up and checks
recorded results
The Fact Photometry · Test process

The photometric testing process is the sequence by which a fixture's light output is measured in the laboratory so that it can be compared with a requirement. The fixture is prepared and mounted, aligned on the goniometer, and run at its rated current until its output is stable. The photometer then reads the intensity at each point of the measurement grid as the fixture is turned, angle by angle.

The readings are checked by repeating a reference reading during and after the scan, so drift in the output, the alignment or the photometer is caught, and any affected part is repeated. The intensities are recorded as a table, with colour measured too (white lights have colour limits as well as coloured ones), and turned into an isocandela diagram and a photometric report, which is compared with the applicable standard.

Set-upMounted and aligned on the goniometer
SupplyRated current, output stable
ScanGrid points, angle by angle
CheckReference reading repeated
RecordIntensity table, plus colour (white lights too)
OutputIsocandela diagram and report
Schematic only. The values and grid shown are examples and this is not a test procedure. The grid, distance, current, tolerances and acceptance limits come from the applicable standard and the test laboratory’s procedure.
Entry 23 · Fixture alignment Entry 25 · Photometric report interpretation

Frequently Asked Questions

Q1What is the photometric testing process?

It is the fixed sequence by which a fixture's light output is measured in a laboratory: prepare and mount the fixture, align it, run it at rated current until it settles, scan the measurement grid angle by angle, check and record the readings, and produce a report from the data.

Q2Why must the fixture be stabilised before measuring?

Its output changes while it warms up, so readings taken too early do not represent the fixture in service. It is run at its rated current until the output is steady, and the output is checked again during and after the scan to confirm it has not drifted.

Q3How is the beam measured across all its angles?

The fixture is turned on the goniometer so that the photometer, at a fixed distance, reads the intensity at each point of the measurement grid in turn. The grid covers the horizontal and vertical angles needed to describe the beam, with finer spacing where the intensity changes quickly.

Q4Why are readings checked during the test?

A repeat reading at a reference angle shows whether the output, the alignment or the photometer has drifted during the scan. If it has, the readings are suspect and the affected part of the test is repeated rather than reported.

Q5What does the test produce?

A table of intensity at each angle, which is turned into an isocandela diagram and a photometric report. Colour is measured as well, because white lights have chromaticity limits just as coloured ones do. The report is then compared with the requirement in the applicable standard.

Q6Who decides the test conditions and limits?

The applicable standard and the test laboratory's procedure set the grid, distance, current, tolerances and acceptance limits. The sequence here is the common pattern, and the details are not set by this entry.

Precision AGL Academy

See It. Understand It. Then Learn How to Engineer It.

Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how each light, sign and circuit works as part of a complete airport lighting system, not just as an isolated diagram.

See. Understand. Apply. Engineer.