THE AGL ENGINEERING CENTRE by Precision AGL Academy · Runway Photometry

Runway Lighting Photometry: Intensity, Coverage, Colour & Testing

How photometry measures the intensity, distribution, colour and alignment of runway edge, threshold, end, centreline, touchdown zone and approach lights. A runway light can be switched on and still give too little output, the wrong beam pattern or the wrong direction.

Overview

What Is Runway Lighting Photometry?

Runway lighting photometry is the measurement and evaluation of the optical performance of runway lighting fixtures. It shows whether installed lights give the intensity, distribution, colour and alignment their operational function needs, and it answers a different question from "is the lamp on?"

Why on/off is not enough

Two runway edge lights can look alike during a night inspection while one has much lower output or a displaced beam. Photometry finds differences that visual inspection cannot judge reliably.

When it is carried out

Commissioning, periodic inspection, preventive maintenance, rehabilitation, troubleshooting, and after replacement of runway lighting equipment.

Depending on the fixture and test requirement, measurements may examine

Luminous intensityIntensity distributionBeam coverageOptical alignmentColourRelative uniformityFixture-to-fixture consistencyChange from baselineDegradation over time
Acceptance criteria come from the governing aerodrome standard, approved project specification, equipment requirements and authority documentation. ICAO Annex 14 Volume I is the principal international reference for visual aids. FAA maintenance guidance (AC 150/5340-26C) notes that regular photometric measurement can identify reduced output and misalignment and target maintenance where it is needed.
Purpose

Why Runway Photometry Is Important

Runway lights form a visual guidance system, and their usefulness depends on the pilot receiving a consistent and unambiguous visual pattern. A photometry programme supports both compliance verification and condition-based maintenance.

Low intensity

A lamp, LED assembly or optical system can degrade while still operating.

Misalignment

The fixture produces light, but the main beam may no longer point the right way.

Contaminated optics

Rubber deposits, dirt, dust and moisture cut output, especially for in-pavement fixtures.

Incorrect colour

Lenses, filters or light sources can deteriorate and move colour out of requirement.

Incorrect installation

A replacement fixture or optical assembly may be oriented or installed wrongly.

Uneven performance

Individual fixtures can drift away from the rest of the lighting system.

Programme

Planning a Runway Photometry Programme

Plan around the runway configuration, lighting system, operational category, equipment type and inspection requirements. A typical programme runs from drawing review to the final report.

Review drawings and data
Select fixtures
Verify instrument
Inspect and clean
Confirm electrical condition
Measure
Compare with criteria
Maintain or adjust
Retest
Report

Commissioning

After new installation, rehabilitation or major modification. Sets the baseline.

Periodic

Monitors installed performance during operation and builds a history.

Maintenance

Locates fixtures that need cleaning, adjustment, repair or replacement.

Acceptance

Shows installed equipment meets project or authority requirements.

Troubleshooting

Used when intensity looks inconsistent or misalignment is suspected.

Interactive

What to Test on Each Runway Fixture Type

Pick a fixture type to see what the test should cover. This is a planning aid, and the approved specification sets the actual parameters and limits.

Test should consider

    Watch for

      Fixtures

      Runway Edge, Threshold, End, Centreline, Touchdown and Approach Lights

      Each light type has a different optical function, so the measurement method and acceptance criteria must match the fixture and the runway configuration.

      Light typePrimary functionParticular test attention
      EdgeLateral guidanceOrientation relative to runway geometry; in-pavement fixtures add lens contamination and water
      ThresholdMarks the start of the usable landing portionDirection, intensity and distribution as well as colour
      Runway endMarks the runway end; may be bidirectionalTest each viewing direction the fixture serves
      CentrelineLongitudinal guidanceOptical window condition, contamination, spacing consistency
      Touchdown zoneGuidance in the touchdown areaAdjacent-unit consistency, moisture and debris protection
      ApproachApproach visual guidanceComplete pattern and array consistency, not single-fixture comparison

      A fixture that draws the correct electrical current but produces degraded optical output has not necessarily met its operational requirement.

      Measurement

      Intensity, Colour and Coverage

      Intensity

      Depends on fixture design, light source, optics, operating step, beam direction, measurement geometry, environment and fixture condition. Controlled, repeatable conditions are required.

      Colour

      Intensity and colour are related but separate checks. A fixture with acceptable intensity can still have degraded colour from filter, lens or light-source ageing.

      Coverage

      Whether enough output is given over the required angular region. A high peak intensity can still fail the distribution.

      Intensity at different brightness steps

      Report the operating condition used (low, intermediate or high step, where those apply). Comparing a fixture measured at one step with a specification for another gives misleading results.

      Absolute versus comparative

      Absolute: the measured value is compared directly with a specified limit. Comparative: the result is compared with baseline, neighbouring fixtures or history, which can expose a progressive loss before a formal failure.

      How Is Runway Light Intensity Measured?

      Runway light intensity is measured with calibrated photometric test equipment under controlled, repeatable conditions. The fixture is inspected and, where the procedure permits, cleaned first. The sensor position, distance, viewing direction, height and fixture orientation are then fixed and recorded, and the circuit is set to the required brightness step. The reading is compared with the applicable acceptance criterion or with baseline data, using the same geometry each time. See the measurement procedure below for the full ten stages.

      Analyse more than peak output

      AspectWhat it tells you
      Peak outputLight produced in the principal measurement direction
      Angular distributionHow output changes with viewing angle
      Useful coverageWhether intensity holds across the required beam region
      ConsistencyWhether adjacent fixtures give a comparable and appropriate pattern

      Colour evaluation may consider

      Spectral characteristicsColour coordinatesConsistency between fixturesOptical degradationFilter conditionLED or light-source performance
      Take exact colour criteria from the applicable aerodrome standard and approved fixture specification, not from a generic website value, including this one.

      Runway lighting plan: which lights are where.

      LANDING DIRECTIONTHRESHOLD LIGHTS+ WING BARSRUNWAY END LIGHTSEDGE LIGHTS · 60 m MAX SPACINGRUNWAY CENTRELINE LIGHTSTOUCHDOWN ZONE LIGHTSTOUCHDOWN ZONE · FIRST 900 mCENTRELINE LIGHT COLOUR · RED/WHITE 900–300 m, RED LAST 300 mWHITERED / WHITEREDEDGE LIGHT COLOUR (SEEN FROM THE APPROACH)WHITEYELLOW · LAST 600 mPLAN VIEW · ILLUSTRATIVE, NOT TO SCALE · 3000 m RUNWAY SHOWN
      Figure 1. Plan view of runway lighting. Not every light has the same photometric requirement.
      AGL Visual Encyclopedia: Runway lighting layout Runway edge lights Threshold lights

      Coverage as isocandela contours.

      THE DIAGRAM · ANGLE GRID curves of equal candela around the beam axis READING IT · BANDS AND SPACING between two curves, close or wide apart 50 % OF PEAK 10 % OF PEAK LEFT RIGHT UP HORIZONTAL AND VERTICAL ANGLE FROM THE BEAM AXIS P 1 2 3 4 PEAK 50 % 10 % P LIES BETWEEN 10 % AND 50 % OF PEAK read from the two curves around it 6 CLOSE steep fall WIDE gentle fall 5 1ANGLE GRIDhorizontal across, vertical up, beam axis at centre 2CURVE OF EQUAL CANDELAevery direction on it has the same intensity 3PEAK ON THE AXIShighest intensity, centre of the rings 4READ A DIRECTIONfind its angles, see the two curves around it 5CURVE SPACINGclose curves mean a quick change in intensity 6COMPARE WITH THE STANDARDmeasured against the required diagram CORRECT READINGBY ANGLE, THEN BETWEEN TWO CURVESDirection in, intensity band out WRONG READINGTHE PEAK VALUE ONLYSame peak, very different beams SCHEMATIC · ILLUSTRATIVE LEVELS · NOT A STANDARD DIAGRAM · SEE ICAO ANNEX 14 VOL. I, APP. 2
      Figure 2. Isocandela diagram: peak, 50 percent and 10 percent contours. A high peak can still fail the distribution.
      AGL Visual Encyclopedia: Isocandela diagram Photometric distribution Beam pattern
      Two airmen examining an LED light on a runway
      Photo 1. Airmen examine an LED light on a newly completed runway. Intensity, colour and coverage are separate checks.Credit: U.S. Air Force photo by Sonic Johnson, Columbus Air Force Base, Sept. 3, 2013. Public domain (US Government work). Source page
      Equipment

      Runway Photometer, Calibration and Test Equipment

      What a runway photometer does

      An instrument or measurement system for the optical output of airport lighting fixtures. Depending on the equipment it measures or calculates luminous intensity, distribution, angular position, colour-related information, fixture orientation, beam characteristics and location. Mobile systems allow rapid measurement of runway installations and help locate deficient fixtures.

      A typical system may include

      Photometric sensor, optical sensor or camera, positioning, distance and angular measurement, data acquisition unit, computer or tablet, software, fixture identification database and calibration references. Mobile systems add location tracking and automated processing.

      Before testing, verify

      • Instrument identification and calibration status
      • Calibration certificate, reference or traceability requirements
      • Measurement range and sensor condition
      • Software or data-acquisition configuration
      • Date and time settings
      A result from an instrument with uncertain calibration status is not equivalent to a controlled measurement. The equipment needs accuracy and repeatability suited to the acceptance or maintenance purpose.

      Fixture on a rotating stage, photometer at a measured distance.

      PHOTOMETER ARRANGEMENT · SIDE VIEW · SCHEMATICDARK ROOMBAFFLESdTEST DISTANCEFIXTURE ROTATES · PHOTOMETER STAYS FIXED123451FIXTURE ON STAGERotates to each test angle2BEAM AXISAimed at the photometer3TEST DISTANCELong enough for a point source4PHOTOMETERFixed detector reads the light5STRAY LIGHT CONTROLDark room and bafflesSCHEMATIC · PROPORTIONS ARE ILLUSTRATIVE, NOT A TEST SETUP DRAWING
      Figure 3. Photometer arrangement in a dark room with baffles. Verify calibration and the complete test arrangement.
      AGL Visual Encyclopedia: Photometer arrangement Photometric testing arrangement Automated photometry
      Procedure

      Runway Photometry Measurement Procedure

      A controlled test follows ten stages. Do not assume the same acceptance limits apply to every runway or fixture type.

      01

      Review the test requirements

      Runway, lighting system, fixture types, scope, standards, specifications, acceptance criteria, operating settings and measurement points.

      02

      Review drawings and asset information

      Layout, runway geometry, fixture schedule, datasheets, earlier photometric reports, maintenance history and as-builts.

      03

      Verify test equipment

      Calibration, identification, software set-up, sensor configuration, range, date and time, data storage.

      04

      Inspect the runway lighting

      Damaged lenses, contamination, missing fixtures, damaged housings, wrong orientation, water ingress, loose fittings, damaged cables or connectors, abnormal illumination. Clean before final acceptance measurements where the procedure permits.

      05

      Establish measurement geometry

      Sensor position, distance, viewing direction, height, horizontal and vertical alignment, angle and fixture orientation. Use the same geometry when comparing.

      06

      Operate at the required setting

      Set the specified test intensity and record the actual operating condition.

      07

      Measure the fixtures

      Each fixture or the specified representative set, linked to runway, type, fixture ID, station, step, date and time, and result.

      08

      Evaluate the results

      Compare with acceptance criteria and classify: pass, fail, investigate, maintenance required or retest required.

      09

      Correct deficiencies

      Cleaning, optical adjustment, realignment, lens, lamp, LED module or fixture replacement, electrical troubleshooting, transformer or connector inspection, water-ingress correction.

      10

      Retest

      Remeasure corrected fixtures. A light that is visible again is not proof of the required optical performance.

      Test points depend on the fixture and specification

      Horizontal distributionVertical distributionMain beam intensityColourBeam coverage
      Where acceptance is based on a distribution, evaluate more than a single peak intensity value.

      The measurement procedure at a glance.

      PHOTOMETRIC TESTING PROCESS · SEVEN STEPS, FROM MOUNTING TO REPORT 1 PREPARE Identify & mount 2 ALIGN Axis & centre 3 STABILISE Rated current 4 SCAN Grid, angle by angle 5 CHECK Repeat reference 6 RECORD Data table 7 REPORT Isocandela & report STEP 4 · SCANNING THE MEASUREMENT GRID · ONE READING PER GRID POINT HORIZONTAL ANGLE → VERTICAL ANGLE → INTENSITY TABLE H 0 / V 0 1850 cd H 2 / V 0 1420 cd H 0 / V 2 1610 cd H 2 / V 2 1180 cd EXAMPLE VALUES ONLY ISOCANDELA DIAGRAM & PHOTOMETRIC REPORT REPEAT A REFERENCE READING DURING AND AFTER THE SCAN DRIFT FOUND → REPEAT THAT PART, DO NOT REPORT IT RING = FINER SPACING NEAR THE PEAK COLOUR ALSO MEASURED FOR COLOURED LIGHTS SCHEMATIC · EXAMPLE VALUES ONLY · LIMITS FOLLOW THE STANDARD AND LABORATORY PROCEDURE
      Figure 4. Simplified photometric testing process. The ten numbered stages on this page give the full sequence.
      AGL Visual Encyclopedia: Photometric testing process Photometric grid Measurement points
      Troubleshooting

      Common Photometry Failures and Troubleshooting

      Click a failure to see the causes to investigate.

      Low light intensity

      Possible Cause

      • Degraded lamp or LED
      • Optical contamination
      • Damaged lens
      • Incorrect lamp type
      • Ageing optical components
      • Electrical problems
      • Incorrect intensity step

      Misalignment

      Possible Cause

      • Physical impact
      • Incorrect installation
      • Loose mounting
      • Maintenance error
      • Fixture movement
      • Foundation or mounting problems

      Dirty optical surfaces

      Possible Cause

      • Rubber deposits
      • Dirt and dust
      • De-icing materials
      • Standing water
      • Pavement debris

      Water ingress

      Possible Cause

      • Optical degradation and condensation
      • Electrical failures
      • Corrosion
      • Failed enclosure, gasket, lens seal or drainage

      Incorrect replacement component

      Possible Cause

      • Wrong lamp, optical assembly or part altering the photometric output
      • Lamps other than those approved for the fixture

      Wrong operating current or brightness setting

      Possible Cause

      • Fixture measured at a different intensity step from the specification
      • Operating condition not recorded in the test data

      Electrical circuit problems

      Possible Cause

      • Poor connections
      • Cable degradation
      • Isolation transformer problems
      • Connector faults
      • Abnormal series-circuit conditions
      • Incorrect regulator operation

      Investigation sequence for an abnormal result

      Abnormal result
      Confirm set-up
      Confirm calibration
      Confirm intensity step
      Inspect and clean
      Check alignment
      Inspect optics
      Check electrical supply
      Repair or replace
      Repeat measurement

      This sequence stops a team replacing a fixture when the real cause is contamination, alignment or an upstream electrical issue. The optical result also points troubleshooting toward either the fixture or the electrical system.

      Four common photometric failures as contours.

      PHOTOMETRIC FAILURE · REQUIRED AREA DRAWN OVER THE MEASURED CONTOURS 1 TOO DIM CONTOURS SHRINK Required box not reached Dirty lens · ageing · low current 2 BEAM SHIFTED CONTOURS OFF TARGET Peak outside the box Mis-aimed · off reference axis 3 BEAM TOO NARROW CONTOURS STRETCHED Box sides uncovered Wrong or damaged optic 4 COLOUR FAILURE CHROMATICITY (x, y) COLOUR LIMITS MEASURED INTENSITY MAY BE FINE Colour point outside its box Faded filter · wrong source 1 OVERLAY Requirement on the diagram 2 FIND What is uncovered or out of limit 3 TRACE Shape points to the cause FIXTURE OR TEST? CHECK ALIGNMENT AND SET-UP BEFORE CONDEMNING THE FIXTURE SCHEMATIC · SHAPES ARE ILLUSTRATIVE · REQUIRED AREAS AND LIMITS COME FROM THE APPLICABLE STANDARD
      Figure 5. Too dim, off-axis, wrong shape and wrong colour, each shown against the required area.
      AGL Visual Encyclopedia: Photometric failure visualization Misalignment LED failure
      An electrical systems craftsman checking a constant current regulator
      Photo 2. An electrical systems craftsman checks a constant current regulator before checking the airfield lights. Not every poor photometric result is optical.Credit: U.S. Air Force photo by Senior Airman Rusty Frank, Spangdahlem Air Base, Jan. 23, 2014. Public domain (US Government work). Source page
      Alignment

      Photometry and Alignment

      How alignment errors arise

      Vehicle impact, maintenance work, fixture replacement, pavement work, foundation movement, incorrect installation and mechanical loosening.

      What photometry shows

      An incorrectly aligned light can look bright from the wrong location. Photometric measurement shows whether the optical output is delivered in the intended direction, so use it together with runway geometry and fixture orientation data.

      Why alignment changes the measured peak.

      FIXTURE ALIGNMENT · GONIOMETER SIDE VIEW · ALIGNED VS MISALIGNED ALIGNED ROTATION AXIS PHOTOMETER REFERENCE AXIS ON PHOTOMETER LINE LIGHT CENTRE ON AXIS · ZERO ANGLES TRUE PEAK READS AT THE DESIGNED ANGLE MISALIGNED ROTATION AXIS PHOTOMETER MISSES AXIS ROTATED · LIGHT CENTRE OFF AXIS WHOLE PATTERN SHIFTED OR ROTATED PEAK AT THE WRONG ANGLE · POINT VALUES WRONG 1 MOUNT On the reference surface 2 CENTRE Light centre on the axis 3 AIM Axis at the photometer 4 ZERO Set the zero angles 5 RECORD Lock it, then measure SCHEMATIC · ANGLES EXAGGERATED · METHOD AND TOLERANCES FOLLOW THE TEST LABORATORY’S PROCEDURE
      Figure 6. Aligned and misaligned fixture on a photometric goniometer.
      AGL Visual Encyclopedia: Fixture alignment in photometry Runway fixture alignment Alignment verification
      Failed Results

      Handling a Failed Photometric Result

      A failed measurement is not automatically a failed fixture. Validate the measurement before assigning maintenance.

      Check the measurement

      • Test instrument calibration
      • Test geometry
      • Sensor alignment
      • Operating intensity
      • Fixture identification
      • Measurement repeatability

      Then check the fixture

      • Contamination
      • Physical alignment
      • Optical condition
      • Electrical condition

      Retest after

      Cleaning for low outputRealignmentRepairRe-lampingNew optical assemblyFixture replacementPavement workAny other corrective action

      Why retesting matters

      Maintenance can fix one problem and introduce another: a lens replacement may alter output, a realignment may move the beam away from another required direction, a replacement lamp may differ optically, and a replacement fixture may mount at a different orientation.

      Retest conditions

      Where practical, retest under conditions comparable with the original measurement. Show success by measurement rather than assuming it.

      Compare with limits, then pass or investigate.

      PHOTOMETRIC COMPLIANCE FLOW · FROM REQUIREMENT TO SIGNED RESULT 1 REQUIREMENT Required areas and colour limits from the standard OUTPUT: CRITERIA 2 SET-UP Calibrated meter, aligned fixture, set current step OUTPUT: READY 3 MEASURE Intensity on the grid and chromaticity of the light OUTPUT: DATA 4 COMPARE Overlay results on the required areas and limits OUTPUT: FIT OR GAP 5 ALL RESULTS WITHIN LIMITS? YES NO PASS Sign the report and file it with the compliance matrix OUTPUT: SIGNED REPORT FAIL Check alignment and set-up, then trace the cause RETEST Fix the cause, repeat from step 2 and record it BACK TO STEP 2 ALL THREE MUST HOLD 1 INTENSITY Every point meets its required value 2 COLOUR Chromaticity inside its limit box 3 BEAM Pattern covers the area, aimed correctly NEVER MOVE THE LIMIT TO FIT THE RESULT · RECORD EVERY RETEST SCHEMATIC · EXAMPLE FLOW ONLY · NOT TO SCALE
      Figure 7. Photometric compliance flow: requirement, set-up, measure, compare, then pass or investigate and retest.
      AGL Visual Encyclopedia: Photometric compliance flow Photometric acceptance Before and after photometry
      An airman adjusting an airfield light fixture while replacing the bulb
      Photo 3. An airman adjusts an airfield light fixture while replacing the bulb. After a fix, retest and compare with the earlier result.Credit: U.S. Air Force photo by Senior Airman Kenny Holston, Shaw Air Force Base, June 26, 2012. Public domain (US Government work). Source page
      Records

      Commissioning, Periodic Testing and the Photometric Report

      Commissioning baseline

      Document installed fixture type, location, equipment ID, operating condition, measurement equipment, calibration status, measured performance, acceptance criteria, pass/fail result, corrective actions and final retest. The report becomes the baseline for later tests.

      Periodic testing

      Compare current and previous intensity, fixture-to-fixture variation, repeated fault locations, maintenance frequency and trends. Frequency follows authority requirements, airport conditions, equipment condition and the approved maintenance programme.

      Example data table

      Fixture IDLocationFixture typeIntensity stepMeasured resultAcceptance criterionResult
      RW-EL-001Runway edgeEdge lightSpecified stepRecorded valueApplicable limitPass
      RW-EL-002Runway edgeEdge lightSpecified stepRecorded valueApplicable limitPass
      RW-CN-001CentrelineIn-pavementSpecified stepRecorded valueApplicable limitInvestigate
      Take acceptance values from the governing specification. Do not insert generic values without confirming their source.

      Project and equipment

      Airport, runway, reference number, date, conditions, organisation, personnel; photometer manufacturer, model, serial, sensor ID, calibration certificate and software version.

      Lighting information

      Fixture type, manufacturer, model, ID, location, installation type, operating intensity and relevant electrical configuration.

      Five questions it must answer

      What was tested, how, what was measured, what it should have been (with source), and what happened after a failure.

      A good report records the full chain: measurement, defect, corrective action, verification. Record failures fixture by fixture, not as one runway pass/fail.

      Reading a photometric report in six steps.

      PHOTOMETRIC REPORT · SIX THINGS TO READ, IN ORDER 1 IDENTIFY What was tested 2 CONDITIONS Current, distance 3 DATA Table & isocandela 4 COMPARE Against requirement 5 COLOUR Chromaticity 6 CONCLUDE Result & limits EXAMPLE REPORT SHEET · READ AGAINST THE REQUIREMENT, NOT ON ITS OWN 1 FIXTURE · SOURCE · COLOUR · LABORATORY · DATE 2 RATED CURRENT · TEST DISTANCE · STANDARD USED 3 ISOCANDELA DIAGRAM · DASHED BOX = REQUIRED AREA 5 CHROMATICITY x, y inside the colour limits 4 POINT-BY-POINT COMPARISON POINT REQUIRED MIN MEASURED RESULT A (0, 0) 1500 cd 1850 cd PASS B (+2, 0) 1000 cd 1120 cd PASS C (-2, 0) 1000 cd 960 cd FAIL D (0, +1) 800 cd 880 cd PASS ONE POINT BELOW ITS LIMIT IS A FAILURE · EXAMPLE VALUES ONLY 6 RESULT APPLIES TO THE TESTED SAMPLE UNDER STATED CONDITIONS SCHEMATIC · EXAMPLE VALUES ONLY · REQUIRED POINTS AND LIMITS COME FROM THE APPLICABLE STANDARD
      Figure 8. Photometric report interpretation. Take acceptance values from the governing specification.
      AGL Visual Encyclopedia: Report interpretation Data interpretation Photometric inspection
      Comparison

      Photometry vs Visual Inspection

      The two are complementary. A light that looks acceptable to an inspector may not meet its photometric requirement, so a maintenance programme uses both.

      FindingVisual inspectionPhotometry
      Burned-out lightsYesYes
      Damaged fixtures and broken lensesYesLimited
      Contamination and water ingressYesShows the effect on output
      Obvious misalignmentYesYes
      Reduced intensitySubjectiveYes
      Quantitative degradationNoYes
      Beam displacement and distributionLimitedYes
      Inconsistent performance and trendsLimitedYes

      Where photometry sits in AGL maintenance

      Visual inspectionFixture cleaningElectrical testingInsulation testingTransformer inspectionCCR testingCable and connector inspectionMechanical inspectionAlignment checksPhotometric measurement
      CCR
      Primary series circuit
      Isolation transformer
      Secondary circuit
      Light fixture
      Optical output
      A low photometric result can trigger investigation at the fixture or further upstream in the electrical system.
      Runway lights illuminated at night at an air base
      Photo 4. Runway lights lit at night. A defective light found by inspection is annotated in the checklist for replacement; photometry measures what the eye cannot.Credit: U.S. Air Force photo by Airman 1st Class Sean Campbell, Fairchild Air Force Base, Oct. 21, 2015. Public domain (US Government work). Source page
      Checklists

      Runway Lighting Photometry Checklist

      Click an item to mark it complete.

      Before testing

      Runway lighting drawings reviewed
      Test scope confirmed
      Fixture types identified
      Standards and specifications reviewed
      Photometer calibration verified
      Previous results reviewed
      Weather and operational conditions checked
      Fixtures inspected and cleaned where required
      0 / 8 complete

      During testing

      Runway and fixture identification recorded
      Fixture position confirmed
      Operating intensity confirmed
      Measurement geometry kept consistent
      Required parameters measured
      Abnormal results recorded
      Questionable measurements repeated
      0 / 7 complete

      After testing

      Results analysed
      Failures identified and located
      Corrective maintenance performed
      Repaired fixtures retested
      Final report prepared
      Maintenance or asset database updated
      Baseline and historical results preserved
      0 / 7 complete
      Best Practice

      Runway Photometry Best Practices

      1

      Use calibrated equipment

      Accuracy begins with controlled instrumentation.

      2

      Use repeatable geometry

      Changes in sensor position create misleading differences.

      3

      Identify every fixture

      Data must trace to an exact runway location.

      4

      Record the operating condition

      Tie intensity results to the correct lighting step.

      5

      Clean before final acceptance

      Contamination can artificially lower measured output.

      6

      Record failures individually

      Do not report only an overall runway pass/fail.

      7

      Maintain historical data

      Trend analysis shows deterioration.

      8

      Retest corrective work

      Confirm a repair by measurement.

      9

      Reference the exact criteria

      Identify the source of every requirement.

      Workflow

      Recommended End-to-End Workflow

      Run photometry as an asset-management tool across the life of the installation, not as a one-time acceptance activity.

      01

      Design review

      Confirm fixture types and photometric requirements.

      02

      Installation

      Verify physical and optical installation.

      03

      Pre-commissioning inspection

      Check condition, orientation and cleanliness.

      04

      Photometric measurement

      Measure intensity, distribution, colour and applicable optical parameters.

      05

      Acceptance evaluation

      Compare with approved criteria.

      06

      Corrective action

      Clean, align, repair or replace.

      07

      Retest

      Verify the corrective action.

      08

      Baseline report

      Establish initial performance data.

      09

      Periodic testing

      Repeat measurements in service.

      10

      Trend analysis

      Identify progressive degradation.

      Reference

      Standards and Acceptance Criteria

      ICAO Annex 14, Vol. I

      International SARPs for aerodrome design and operation, including visual aids. The ICAO Store lists the 9th Edition (July 2022) with Amendment 18 and later corrigenda.

      FAA AC 150/5345-46

      Specification for runway, taxiway, heliport and vertiport light fixtures. Edition F (30 September 2024) is cited here.

      FAA AC 150/5340-26C

      Maintenance of Airport Visual Aid Facilities, including cleaning and photometric measurement.

      National authority and project

      Runway type, operational category, fixture type, approved equipment specification, project design and airport maintenance procedures.

      Requirements depend on ICAO, national authority, FAA where applicable, runway type, operational category, lighting configuration, fixture type and the approved specification. Take final criteria from the current controlled document, never from an unrelated airport or outdated standard, and confirm the edition before you rely on any figure.

      Four checks feed one acceptance decision.

      THE 4Cs · ACCEPTANCE DECISIONCOLOURChromaticityCANDELAIntensityCOVERAGEBeam spread and aimCONFIGURATIONPlacement and layoutALL FOURMEET?YESNOACCEPTREJECTINVESTIGATERETEST123451COLOURChromaticity within its region2CANDELAIntensity meets the requirement3COVERAGEBeam spread and aim are correct4CONFIGURATIONPlacement, spacing, layout5DECISIONEvery C must pass to acceptSCHEMATIC · THE ACTUAL CRITERIA COME FROM THE STANDARD AND THE PROCEDURE
      Figure 9. Colour, candela, coverage and configuration each feed the accept or reject decision.
      AGL Visual Encyclopedia: Photometric acceptance Photometric compliance flow Photometric performance
      Final Engineering Perspective

      A runway light that is on has not yet shown that it is working. Measure the optical output, record it, and retest every correction.

      Measure the light. Verify the direction. Prove the repair.

      Test Yourself

      Quick Knowledge Check

      Q1. Why can a runway light pass visual inspection and still fail photometry?

      A. It cannot
      B. Visual inspection cannot judge intensity, distribution or beam direction reliably
      C. Photometry checks only the lamp
      D. Visual inspection tests colour more accurately

      Q2. What should be done first after a fixture fails a photometric measurement?

      A. Replace the fixture
      B. Validate the measurement: calibration, geometry, intensity step and identification
      C. Raise the brightness step
      D. Ignore a single failure

      Q3. Why must the operating intensity step be recorded?

      A. It is only a formality
      B. A result measured at one step can be wrongly judged against a specification for another
      C. Steps do not change output
      D. It sets the calibration date

      Q4. What does comparative photometry compare a result with?

      A. A different airport
      B. Baseline, neighbouring fixtures or historical data
      C. Only the nameplate
      D. A visual impression

      Q5. Why must a corrected fixture be retested?

      A. The light is visible again, so it is proven
      B. A repair can fix one problem and change optical output or beam direction
      C. Retesting is optional
      D. Only to update the date
      Explore More

      Explore More AGL Engineering

      FUNDAMENTALS

      AGL Photometry

      Photometry concepts, equipment and reporting.

      Open AGL Photometry →
      FIELD GUIDE

      AGL Photometric Testing Guide

      Equipment, measurement procedure and troubleshooting.

      Open AGL Photometric Testing Guide →
      SYSTEM

      Runway Lighting Systems

      Runway lighting layouts and functions.

      Open Runway Lighting Systems →
      SYSTEM

      Approach Lighting Systems

      Approach lighting configurations.

      Open Approach Lighting Systems →
      VISUAL AID

      PAPI Engineering Guide

      Working principle, geometry and siting.

      Open PAPI Engineering Guide →
      FIELD GUIDE

      PAPI Alignment, Testing & Maintenance

      PAPI alignment and field practice.

      Open PAPI Alignment, Testing & Maintenance →
      STANDARDS

      ICAO PAPI Requirements

      ICAO PAPI requirements and compliance.

      Open ICAO PAPI Requirements →
      ELECTRICAL

      CCR Working Principle

      Constant current regulators and series circuits.

      Open CCR Working Principle →
      ELECTRICAL

      Airport Isolating Transformer

      Ratings, types and testing.

      Open Airport Isolating Transformer →
      HARDWARE

      Junction Boxes & Transformer Housings

      Light bases and housings.

      Open Junction Boxes & Transformer Housings →

      Measure Output. Maintain Performance.

      From fixture identification to baseline reports and retesting, explore the complete AGL knowledge base for photometry and maintenance.

      AGL Engineering Hub

      Explore the AGL Engineering Knowledge Hub

      Fundamentals

      Standards & Compliance

      Runway, Taxiway & Approach Lighting

      Surface Movement & Safety

      PAPI

      Electrical Engineering & Power

      Photometry & Testing

      Maintenance, Inspection & Safety

      Resources, Documentation & Careers

      FAQ

      Runway Lighting Photometry FAQ

      Q1What is runway lighting photometry?

      Runway lighting photometry is the measurement of the optical performance of runway lighting fixtures, including parameters such as intensity, distribution, colour and alignment.

      Q2Why is runway photometric testing required?

      It verifies that installed lights continue to give the intended visual guidance, and it finds degradation or misalignment that normal visual inspection may not reveal.

      Q3What does a runway photometer measure?

      Depending on the instrument and application, it can measure light intensity, distribution and other optical characteristics, and may also determine alignment or location information.

      Q4How often should runway lights be photometrically tested?

      There is no single universal interval. Follow the applicable authority requirements and the airport maintenance programme, considering runway usage, environmental conditions, equipment reliability and historical performance. FAA guidance lists traffic, pollution, equipment reliability and observed field performance as factors.

      Q5Can photometry detect misaligned runway lights?

      Yes. Photometric measurement can show that a fixture's optical output is not being delivered in the intended direction.

      Q6Can a light pass visual inspection and fail photometry?

      Yes. A fixture can stay illuminated while giving insufficient intensity, an incorrect beam pattern or other degraded optical performance.

      Q7Why are in-pavement runway lights difficult to maintain?

      They are exposed to contamination, rubber deposits, pavement loading, moisture and mechanical stress. These conditions can degrade optical performance even while the fixture keeps operating.

      Q8Should runway lights be cleaned before photometric testing?

      Where the test procedure requires it, clean before final acceptance measurements so contamination is not mistaken for fixture degradation.

      Q9Is intensity alone enough to evaluate a runway light?

      Not always. Depending on the applicable requirement, colour, distribution, beam coverage and alignment may also need to be evaluated.

      Q10What should be included in a runway photometric report?

      Runway and fixture identification, test date, equipment and calibration information, operating condition, measurement method, measured results, acceptance criteria, pass/fail status, corrective actions and retest results.

      Q11What is the difference between absolute and comparative photometry?

      Absolute photometry compares a measured value directly with a specified limit. Comparative photometry compares the result with a baseline, neighbouring fixtures or historical data, which can show a progressive loss of output before a formal failure.

      Q12What should I do when a fixture fails a photometric measurement?

      Validate the measurement first: instrument calibration, geometry, sensor alignment, operating intensity and fixture identification. Then check contamination, alignment, optics and the electrical supply before repairing or replacing, and retest afterwards.

      Field Insight

      Engineering & Expert Notes

      Measure the Right Items
      Scope

      Define which fixtures and parameters are tested for each part of the runway.

      Record the Intensity Step
      Settings

      Output varies with the step used. Always note it.

      Check Alignment Alongside Intensity
      Alignment

      Poor aiming can give misleading readings.

      Clean Optics Before Concluding
      Contamination

      Dirt is a common cause of low readings. Clean and retest.

      Handle Failed Results Methodically
      Failures

      Verify setup, then rectify and retest, keeping both sets of data.

      Keep Raw Data
      Records

      Store readings and test conditions with the report.

      Precision AGL Academy

      Understand AGL. Build Your Engineering Skills.

      You now understand how runway lighting photometry verifies intensity, coverage, colour and alignment, from planning and measurement to reporting and retesting.

      Take the next step with Precision AGL Academy.

      Learn AGL Step by Step

      Build your knowledge through structured technical learning covering:

      AGL Fundamentals Components Electrical Systems Design Photometry Testing Troubleshooting Maintenance

      Move from understanding how AGL works to developing the practical knowledge needed to analyse, operate and maintain complete AGL systems.

      Understand the system. Build the knowledge. Apply the engineering.