What is a photometer arrangement?

How the fixture, its rotating stage and the photometer are set out so that intensity can be read at each angle.

PHOTOMETER ARRANGEMENT · SIDE VIEW · SCHEMATICDARK ROOMBAFFLESdTEST DISTANCEFIXTURE ROTATES · PHOTOMETER STAYS FIXED123451FIXTURE ON STAGERotates to each test angle2BEAM AXISAimed at the photometer3TEST DISTANCELong enough for a point source4PHOTOMETERFixed detector reads the light5STRAY LIGHT CONTROLDark room and bafflesSCHEMATIC · PROPORTIONS ARE ILLUSTRATIVE, NOT A TEST SETUP DRAWING
beam axis to photometer
fixture and baffles
rotation of fixture
The Fact Photometry · Test set-up

A photometer arrangement is the physical set-up used to measure a fixture’s light. The fixture is mounted on a rotating stage so it can be turned to each test angle, and a photometer sits at a fixed distance, in line with the beam, reading the light that arrives. In this arrangement intensity at each angle is found by turning the fixture about its photometric centre, not by moving the photometer. The photometer reads illuminance, and intensity in candela follows from the inverse-square law: intensity = illuminance × distance squared.

Three things make the reading valid. The test distance must be long compared with the luminous area of the fixture (a common rule of thumb is at least five to ten times its largest luminous dimension; the test standard or laboratory procedure sets the actual figure) so it acts as a point source, and it must be constant and accurately known, measured from the photometric centre of the fixture to the face of the photometer. The photometer itself must be calibrated, traceable to a national standard and corrected to the response of the eye. The beam axis must be aimed at the photometer, and the photometer must face the fixture. And stray light must be kept out: a dark room with matt black surfaces and baffles stops light reflected from the surroundings from adding to the direct beam. The fixture is also run at the rated current for the brightness step being tested and allowed to settle, so lamp or LED output is stable, before readings are taken.

FixtureOn a rotating stage
PhotometerFixed, facing the fixture
DistanceConstant and long enough
AlignmentBeam axis at the photometer
RoomDark, with baffles
SupplyRated current for the step, settled
ReferenceICAO Annex 14 Vol. I, App. 2; ICAO Doc 9157 Part 4; CIE 121 (goniophotometry of luminaires)
Schematic only. The proportions are illustrative and this is not a test set-up drawing. The required distance, alignment tolerances and laboratory conditions come from the applicable standard and the test laboratory’s procedure.
Entry 21 · Measurement points Entry 23 · Fixture alignment

Frequently Asked Questions

Q1What is a photometer arrangement?

The physical set-up used to measure a fixture's light: the fixture mounted on a rotating stage, a photometer at a fixed distance in line with the beam, and a room arranged to keep stray light out.

Q2Why does the fixture rotate and the photometer stay still?

Intensity is needed at many angles. Turning the fixture about its centre changes the direction being measured while the photometer, at a constant distance, always reads the light coming toward it.

Q3Why does the test distance matter?

The result is only meaningful as intensity if the fixture behaves like a point source at the photometer. The distance therefore has to be large compared with the fixture, and it must stay constant and be measured accurately.

Q4What is the dark room and baffles for?

Light that reaches the photometer by reflecting off walls or other surfaces is not part of the beam and would add to the reading. Matt black surfaces and baffles block it so only direct light is measured.

Q5What must be checked before measuring?

That the beam axis of the fixture is aimed at the photometer and the photometer faces the fixture, that the distance is correct, that the fixture is running at the rated current for the step under test and has settled, and that the photometer calibration is in date.

Precision AGL Academy

See It. Understand It. Then Learn How to Engineer It.

Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.