Low Intensity Obstruction Light
For structures where low-intensity visual identification is applicable.
View DetailsEnhanced visual identification for towers, masts and tall structures
Medium-intensity obstruction lighting provides enhanced visual identification of structures where increased conspicuity is required by the applicable aviation lighting configuration. Configured to structure height, location, operating conditions and aviation authority requirements.
The light provides a higher level of visual identification than low-intensity obstruction lighting for structures requiring enhanced visibility.
Depending on classification, it may operate with steady or flashing output and may form part of a multi-level obstruction-lighting arrangement.
A complete installation may include multiple lights at defined elevations so the obstacle can be identified from relevant viewing directions.
Precision AGL Solutions supplies medium-intensity obstruction lights for towers, masts, communication structures, industrial installations and other tall structures that may present an aviation obstacle.
Type A, Type B or Type C configurations may be selected, with final optical and operating characteristics determined by the project specification. We support selection by optical output, operating mode, mounting, electrical supply and monitoring requirements.
The final lighting arrangement should be established from the approved aviation lighting assessment and applicable regulatory requirements.
Medium-intensity classifications should be selected according to the applicable aviation requirements.
Type A, Type B and Type C requirements should not be assumed solely from the product name. The final configuration should be confirmed against the approved project specification.
| ICAO Type | Colour | Mode | Typical peak intensity | Typical use |
|---|---|---|---|---|
| Type A | White | Flashing (20–60 per minute) | About 20,000 cd by day and at twilight, reduced to about 2,000 cd at night | Day and night marking where strong daytime conspicuity is needed |
| Type B | Red | Flashing (20–60 per minute) | About 2,000 cd | Night marking, with day marking by paint or other means |
| Type C | Red | Steady (fixed) | About 2,000 cd | Night marking where a steady red light is accepted |
ICAO uses medium-intensity lights for structures roughly in the 45 m to 150 m range, with low-intensity lights below that and high-intensity lights above it or where more conspicuity is needed. On tall structures, lights are placed at levels between the top and ground at about equal intervals, normally not more than about 52 m apart. Flashing lights on one structure flash together.
FAA equipment is specified in AC 150/5345-43J as L-865 (white flashing, medium intensity) and L-864 (red flashing). FAA lighting systems are laid out under AC 70/7460-1N. FAA and ICAO systems are not interchangeable, so follow the authority for the project.
Values are typical ICAO figures from Annex 14, Vol. I, Chapter 6. Confirm intensities, flash rates and spacing against the edition and national rules in force, including DGCA India requirements and the NOC conditions for the structure.
| Parameter | Typical Specification |
|---|---|
| Light Type | Medium-intensity obstruction light |
| Configuration | Type A / Type B / Type C, as applicable |
| Light Source | LED or approved source, configuration dependent |
| Colour | Aviation-specified colour |
| Intensity | Classification and project dependent |
| Operation | Steady or flashing |
| Flash Pattern | Configuration dependent |
| Power Supply | Model dependent |
| Power Consumption | Model dependent |
| Monitoring | Local or remote monitoring, where specified |
| Mounting | Structure, mast, tower or project-specific bracket |
| Dimensions | Model dependent |
| Environmental Protection | Outdoor-rated construction, configuration dependent |
| Operating Temperature | Model dependent |
| Cable / Connection | Project-specific interface |
Exact photometric performance, electrical ratings, flash characteristics, dimensions and environmental specifications should be confirmed against the selected product configuration.
The optical arrangement should be selected to suit the structure and required obstruction-lighting configuration.
For structures with complex geometry, multiple lighting levels or significant changes in elevation, the layout should be reviewed as part of the overall aviation obstruction assessment.
Depending on the applicable Type A/B/C configuration, lights may provide steady-burning or flashing operation.
Where flashing lights are specified, the required flash pattern, timing and synchronization should be confirmed during technical selection.
Tall towers, masts and other structures may require multiple lights at different elevations. The number and position of levels depend on the approved obstruction-lighting design. Positions should be selected so that structural elements do not unnecessarily obstruct the intended optical coverage and the structure remains identifiable from relevant directions.
Where multiple flashing obstruction lights are installed on the same structure, coordinated operation may be required.
Synchronization requirements depend on the selected lighting classification and project control philosophy.
Monitoring architecture should be coordinated with the site's electrical, SCADA, building-management or aviation infrastructure where applicable.
The complete electrical installation should be designed to suit the structure, site conditions and applicable electrical requirements.
Where multiple light types or intensities are used on the same structure, the control system should coordinate their operation according to the approved lighting design.
Mounting hardware should provide secure mechanical support while maintaining the required optical orientation.
The mounting arrangement should also allow suitable access for inspection and maintenance.
The selected enclosure, optical window, fasteners and mounting materials should be appropriate for the installation environment.
For coastal or highly corrosive locations, suitable corrosion-resistant materials and protective finishes should be considered.
The obstruction-lighting system should be installed in accordance with the approved project drawings and applicable aviation requirements.
Where required by the project, photometric measurements and functional tests should be performed using suitable calibrated equipment.
LED-based systems can reduce routine light-source replacement requirements, although periodic inspection and system testing remain important.
| Condition | Possible Cause | Recommended Check |
|---|---|---|
| Light not operating | Power or control failure | Check supply, protection and control circuit |
| Reduced optical output | Dirty lens or optical degradation | Inspect and clean optical surface |
| Incorrect flashing | Configuration or controller issue | Check flash settings and controller |
| Lights not synchronized | Timing/control communication fault | Check synchronization circuit |
| Monitoring alarm active | Light, power or communication fault | Review system status and fault indication |
| Intermittent operation | Supply or connection problem | Inspect cable, terminals and connectors |
| Moisture inside enclosure | Seal or cable-entry problem | Inspect enclosure and sealing |
| Light movement | Loose or unsuitable mounting | Inspect and secure mounting assembly |
Medium-intensity lights are suitable for upgrading existing systems where older equipment has become obsolete, difficult to maintain or incompatible with current project requirements.
A replacement should be selected on the complete optical and operational requirements rather than physical compatibility alone.
This information helps determine the appropriate medium-intensity obstruction-lighting arrangement.
Requirements vary with the jurisdiction, structure type, location and aviation authority. Confirm the edition and any national differences before procurement, and base the final design on the approved obstruction-lighting assessment.
We supply aviation lighting equipment for airport, airfield, tower and aviation-infrastructure projects. Our obstruction-lighting solutions can support:
A medium-intensity obstruction light gives a higher level of visual identification than low-intensity lighting for structures that need enhanced visibility. Depending on classification it may operate steady or flashing and may form part of a multi-level arrangement. Typical applications are communication towers, telecom masts, tall utility and industrial structures, tall buildings and cranes.
Type A is white and flashing at 20 to 60 flashes per minute, with a peak intensity of about 20,000 cd by day and at twilight, reduced to about 2,000 cd at night. Type B is red and flashing at 20 to 60 per minute at about 2,000 cd, for night marking with day marking by paint or other means. Type C is red and steady at about 2,000 cd, for night marking where a steady red light is accepted.
ICAO uses medium-intensity lights for structures roughly in the 45 m to 150 m range, with low-intensity lights below that and high-intensity lights above it or where more conspicuity is needed. These are typical figures from Annex 14 Volume I Chapter 6, so confirm them against the edition and national rules in force, including DGCA India requirements and the NOC conditions for the structure.
FAA equipment is specified in AC 150/5345-43J as L-865 (white flashing, medium intensity) and L-864 (red flashing), and FAA lighting systems are laid out under AC 70/7460-1N. FAA and ICAO systems are not interchangeable, so follow the authority for the project. The classification should not be assumed from the product name and must be confirmed against the approved project specification.
On tall structures, lights are placed at levels between the top and ground at about equal intervals, normally not more than about 52 m apart, and flashing lights on one structure flash together. The number and position of levels come from the approved obstruction-lighting design, and positions should avoid structural elements blocking the intended optical coverage.
Where multiple flashing obstruction lights are installed on the same structure, coordinated operation may be required, depending on the selected classification and the project control philosophy. A system can include a common timing reference, local control or a central controller, status monitoring and fault indication, and the required flash pattern, timing and synchronization should be confirmed during technical selection.
Monitoring may cover light operating status, power status, controller status, flashing status, individual light fault indication, communication status and remote alarm output. The architecture should be coordinated with the site electrical, SCADA, building-management or aviation infrastructure where applicable.
The configuration is selected to suit the site supply and control system, covering supply voltage, AC or DC configuration, surge protection, cable entry, local isolation and earthing. Control can include automatic day/night operation, photocell input, scheduled operation, flash control and fault monitoring. Where several light types or intensities are used on the same structure, the control system should coordinate them according to the approved lighting design.
Verify mounting and orientation, electrical connections, supply voltage and protection, then test steady or flashing operation, colour and optical output, flash characteristics where applicable, and synchronization between lights where required. Test monitoring and alarm functions and photocell operation, and record the results. Where the project requires it, use calibrated equipment for photometric measurements.
A light that is not operating usually points to a power or control failure, and reduced optical output to a dirty lens or optical degradation. Incorrect flashing suggests a configuration or controller issue, lights out of step suggest a timing or control communication fault, and intermittent operation suggests a supply or connection problem. Moisture inside the enclosure indicates a seal or cable-entry problem, and movement of the light a loose or unsuitable mounting.
Provide the structure type, overall height and location, the Type A, B or C requirement if already established, the applicable aviation authority, the required colour, steady or flashing operation and flash characteristics, the number of lighting levels and quantity of lights, the power supply, existing control system, monitoring requirements, mounting arrangement, environmental conditions and whether it is new or a replacement. A replacement should be selected on the complete optical and operational requirements rather than physical compatibility alone.
Indian public tenders commonly ask for the documents below. State which ones your tender requires when you send the enquiry, so they are covered in the quotation.
Planning obstruction lighting for a tower, mast, communication structure or tall airport-adjacent installation? Send us the structure height, location, required Type A/B/C classification, light operating mode, number of lighting levels, power supply and applicable project specification. We can review the application and recommend the appropriate Medium Intensity Obstruction Light configuration, including optical characteristics, mounting, control and monitoring interfaces.
Request obstruction-lighting configuration and technical documentation from Precision AGL Solutions.
Medium-intensity obstruction-light classification, luminous intensity, colour, flash characteristics, lighting levels and operating requirements are application- and authority-dependent. Exact product parameters should be confirmed against the approved aviation lighting assessment and current requirements applicable to the project before procurement or installation.
Product availability, configuration, dimensions, electrical characteristics, photometric performance, certifications and compliance status depend on the selected manufacturer and project specification. The technical values published on this page should not be treated as a substitute for the manufacturer's current approved Technical Data Sheet.
Final selection shall be based on the approved project specification, applicable aviation standards, authority requirements, manufacturer documentation and site conditions. Use of this page is also subject to the Legal Notice, Disclaimer & Terms of Use.
Standards and editions referenced on this site are listed on the Standards Reference page.