Low Intensity Obstruction Light
For applicable low-intensity obstacle-marking applications.
View DetailsMultiple obstruction-lighting functions in one coordinated assembly
Dual and combination beacons suit structures where more than one lighting mode, intensity or operating characteristic is required by the approved obstruction-lighting arrangement, configured for functions, operating conditions, control philosophy and aviation authority requirements.
Dual or combination beacons combine multiple obstruction-lighting functions within a coordinated system, for towers, communication masts, industrial structures, tall infrastructure and other aviation obstacles.
A combination beacon may integrate different lighting characteristics into one assembly, simplifying equipment installation while maintaining the required obstruction-lighting functions. It can reduce layout, cabling and maintenance effort versus separate units where the project permits.
Determine the final configuration from the approved obstruction-lighting assessment and applicable aviation requirements.
Always confirm the final configuration against the approved aviation obstruction-lighting design.
| Parameter | Typical Specification |
|---|---|
| Beacon type | Dual / combination obstruction beacon |
| Lighting modes | Configuration dependent |
| Intensity | Project and classification dependent |
| Colour | Aviation-specified, configuration dependent |
| Operation | Steady, flashing or combined modes |
| Flash characteristics | Configuration dependent |
| Light source | LED or approved source |
| Power supply | Model dependent |
| Power consumption | Model dependent |
| Monitoring | Local and/or remote, where specified |
| Control | Integrated or external, configuration dependent |
| Mounting | Tower, mast, platform or project-specific |
| Dimensions | Model dependent |
| Environmental protection | Outdoor-rated construction, configuration dependent |
| Operating temperature | Model dependent |
| Cable / connection | Project-specific interface |
Confirm exact optical, electrical, mechanical and environmental parameters against the selected beacon configuration.
Establish the operating sequence during project engineering and reflect it in the approved control philosophy.
| Light type | Mode and colour (ICAO Annex 14 Ch. 6) | Typical use |
|---|---|---|
| Low-intensity, Types A and B | Steady (fixed) red | Lower levels of a structure, and low obstacles |
| Medium-intensity, Type A | Flashing white (about 20,000 cd by day and twilight, 2,000 cd at night) | Day, twilight and night marking of structures |
| Medium-intensity, Type B | Flashing red | Night marking; often paired with Type A as a dual system |
| Medium-intensity, Type C | Steady red | Night marking of extensive objects |
| High-intensity, Types A and B | Flashing white (about 200,000 cd Type A or 100,000 cd Type B by day, 20,000 cd at twilight, 2,000 cd at night) | Tall structures; day and twilight marking, reduced at night |
Intensity values, number of levels and spacing come from the approved obstruction-lighting assessment. Medium and high-intensity levels differ between ICAO and FAA, so confirm the standard used for the project.
Do not select intensity solely by structure height. The approved aviation obstruction-lighting assessment determines the configuration.
Exact flash characteristics are configuration-dependent; confirm during technical selection.
Depending on the project, synchronization may use a dedicated timing arrangement or another approved reference.
Integrate with an existing site SCADA, building-management or airport infrastructure system where compatible interfaces are required.
The architecture should ensure the required lighting mode is selected reliably and abnormal operating conditions can be identified.
Where several functions share one beacon, the design should clearly identify supply and control requirements for each function.
Maintain the required optical orientation with secure support under site wind and vibration conditions, and provide access for inspection, testing and maintenance.
Select enclosure, optics, fasteners and mounting materials for site conditions. For corrosive environments, consider suitable materials and protective finishes during engineering.
Larger installations may connect multiple beacon assemblies to a common control and monitoring system, adapted for lighting levels, redundancy, monitoring philosophy and site infrastructure.
Where required, perform photometric and functional verification with suitable calibrated equipment.
Follow manufacturer recommendations, site procedures and applicable aviation requirements.
| Condition | Possible Cause | Recommended Check |
|---|---|---|
| One lighting function not operating | Power, control or light-source fault | Check corresponding supply and controller |
| Entire beacon not operating | Loss of power or common control fault | Check supply, protection and controller |
| Incorrect operating mode | Control or configuration issue | Verify mode-selection logic |
| Flashing incorrect | Controller or configuration fault | Check flash settings |
| Multiple beacons unsynchronized | Timing or communication fault | Inspect synchronization system |
| Monitoring alarm active | Light, controller or communication fault | Review system status |
| Reduced optical output | Dirty or damaged optical surface | Inspect and clean optical components |
| Moisture inside enclosure | Seal or cable-entry issue | Inspect enclosure and sealing |
| Mechanical movement | Loose mounting | Inspect and secure mounting hardware |
Modernization may consolidate separate legacy equipment. Select a combination beacon only where its integrated functions satisfy the complete approved obstruction-lighting requirement.
Requirements vary by structure type, location, lighting classification and authority. Confirm during final product selection.
We supply obstruction-lighting equipment for towers, masts, industrial structures and airport infrastructure, supporting multi-function and multi-level systems, flash synchronization, monitoring and alarm integration, modernization and technical selection and documentation.
A dual or combination beacon combines multiple obstruction-lighting functions in one coordinated assembly for towers, communication masts, industrial structures, tall infrastructure and other aviation obstacles. It may integrate different light intensities and colours, flash characteristics and operating modes, day and night functions, and control and monitoring functions. Where the project permits, it can reduce layout, cabling and maintenance effort compared with separate units.
Under ICAO Annex 14 Chapter 6, low-intensity Types A and B are steady red. Medium-intensity Type A is flashing white, about 20,000 cd by day and twilight and 2,000 cd at night, Type B is flashing red and Type C is steady red. High-intensity Types A and B are flashing white, about 200,000 cd for Type A or 100,000 cd for Type B by day, 20,000 cd at twilight and 2,000 cd at night. The mode and colour follow the light type.
A common dual arrangement is white flashing light in day and twilight and red at night, and the FAA uses red/white dual systems. The changeover is made by a photocell or controller at defined ambient light levels. All lights on one structure should flash together unless the design states otherwise, and the control philosophy should be established during project engineering.
The approved aviation obstruction-lighting assessment determines it. It can depend on structure height and location, the aviation obstacle classification, day and night visibility requirements, the applicable regulations, surrounding lighting and the required conspicuity. Intensity should not be selected solely by structure height, and medium and high-intensity levels differ between ICAO and FAA, so confirm the standard used for the project.
They are considered for communication towers and telecommunications masts, tall industrial structures, utility and transmission structures, airport-adjacent infrastructure, elevated platforms and major installations. They also suit towers needing multiple modes or coordinated intensity arrangements, new installations, replacement and modernization projects, and systems requiring integrated monitoring and control. The final configuration comes from the approved obstruction-lighting assessment and applicable aviation requirements.
Flash characteristics, such as duration, interval and repetition rate, are configuration-dependent and should be confirmed during technical selection. Synchronization can coordinate multiple beacons, upper and intermediate lighting levels, separate obstruction-lighting assemblies, and local and central controllers. Depending on the project, it may use a dedicated timing arrangement or another approved reference.
Monitoring can cover light-source and individual lighting-mode status, power, controller, flashing and communication status, fault indication and remote alarm output, and it can be integrated with an existing SCADA, building-management or airport infrastructure system. Automatic control can include day/night switching with a photocell input, mode selection, flash control, synchronization, enable/disable, fault reporting and remote status indication. A failed light should raise an alarm, and the authority should be told if it cannot be restored quickly.
Consider the supply voltage, AC/DC configuration, power consumption, circuit, surge and lightning protection, cable routing, connectors, earthing and the control and monitoring interfaces, and identify the supply and control needs of each function. Mounting on tower platforms, mast tops, brackets or rooftop structures must hold the optical orientation under site wind and vibration and allow access for inspection and maintenance. Select enclosure, optics, fasteners and mounting materials for wind, rain, dust, solar radiation, temperature variation and, where relevant, coastal or industrial corrosion.
If one lighting function is not operating, check its supply, controller and light source. If the whole beacon is out, check the supply, protection and controller. An incorrect operating mode points to mode-selection logic, incorrect flashing to the flash settings and unsynchronized beacons to the timing or communication system. Reduced optical output suggests a dirty or damaged optical surface, moisture inside the enclosure suggests a seal or cable-entry problem and mechanical movement suggests loose mounting hardware. An active monitoring alarm should be reviewed against the system status.
Modernization may consolidate separate legacy equipment, but a combination beacon should be selected only where its integrated functions satisfy the complete approved obstruction-lighting requirement. The retrofit assessment should consider the existing lighting classifications and beacon positions, required intensity, colour and flash characteristics, structure geometry, existing power supply and cable configuration, control system, monitoring interfaces, synchronization and current aviation requirements.
Review against ICAO Annex 14 Vol. I Chapter 6 on obstacle lighting and Doc 9157 Part 4, FAA AC 70/7460-1 (edition 1N issued 11 Aug 2026, cancelling 1M) together with AC 150/5345-43J on obstruction lighting equipment, and DGCA India CAR Section 4 and aviation authority NOC conditions. Also review the approved project documentation, current authority criteria and any national regulation, airport standard or engineering specification. Requirements vary by structure type, location, lighting classification and authority.
Provide the structure type, height and location, the applicable aviation authority, the existing obstruction-lighting configuration, and the required lighting modes, intensity levels, colours, steady or flashing operation and flash characteristics. Also provide the number of beacon positions, the available power supply, any existing control system, synchronization and monitoring requirements, the mounting arrangement, environmental conditions and whether it is a new installation or a retrofit.
Indian public tenders commonly ask for the documents below. State which ones your tender requires when you send the enquiry, so they are covered in the quotation.
Planning a coordinated obstruction-lighting system for a tower, mast, industrial structure or other aviation obstacle? Send the structure height, location, existing lighting arrangement, required lighting modes, intensity requirements, operating characteristics, power supply and applicable project specification. We can review the application and recommend the appropriate Dual / Combination Beacon configuration, including lighting modes, optical characteristics, mounting, control and monitoring interfaces.
Dual and combination beacon configurations are application- and authority-dependent. Lighting modes, intensity, colour, flash characteristics, synchronization, control functions and installation arrangement must be confirmed against the approved aviation obstruction-lighting assessment and current project requirements.
Complete this confirmation before procurement or installation.
Product availability, configuration, dimensions, electrical characteristics, photometric performance, certifications and compliance status depend on the selected manufacturer and project specification. The technical values published on this page should not be treated as a substitute for the manufacturer's current approved Technical Data Sheet.
Final selection shall be based on the approved project specification, applicable aviation standards, authority requirements, manufacturer documentation and site conditions. Use of this page is also subject to the Legal Notice, Disclaimer & Terms of Use.
Standards and editions referenced on this site are listed on the Standards Reference page.