What does overheating look like?

Darkened insulation, a burnt smell, cracked lenses, dimming output and thermal trips — heat building up faster than it can leave, until its cause is removed.

OVERHEATING · HEAT BUILDING UP FASTER THAN IT LEAVES ALLOW TO COOL · ISOLATE & PROVE DEAD BEFORE TOUCHING CAUSES OVERLOAD · HIGH-RESISTANCE JOINT BLOCKED HEAT PATH · NO AIRFLOW HIGH AMBIENT · DIRECT SUN STAGE 1 HEAT BUILD-UP Hotter than designed STAGE 2 STRESS & AGEING Discolours, ages, brittle STAGE 3 DAMAGE Melted, cracked, tripped PROGRESSIVE · WORSENS UNTIL THE CAUSE IS REMOVED LED FIXTURE & DRIVER LESS LIGHT Output drops or shifts colour; driver and LEDs fail early ASSESS & FIND CAUSE CONNECTIONS & JOINTS HOT JOINT High resistance heats, melts insulation, may open the loop CRITICAL · SAFE FIRST ISOLATING TRANSFORMER OVERLOADED Hot case, burnt smell, insulation ageing; check load CRITICAL · SAFE FIRST CCR & ENCLOSURE NO COOLING Blocked vents, failed fan or dirty filter; may alarm or trip ASSESS & FIND CAUSE LOOK FIRST: DISCOLOURED INSULATION · BURNT SMELL · CRACKED LENSES · BLOCKED VENTS & FILTERS RECORD LOAD & TEMPERATURE · THEN FIX THE CAUSE, NOT JUST THE HOT PART SCHEMATIC · SIMPLIFIED · NOT TO SCALE
critical: make safe first
progression / assess and find cause
causes / records
The Fact Progressive fault

Overheating is heat building up in a part faster than it can leave, so the part runs hotter than its design allows. It shows as darkened or discoloured insulation and paint, a burnt smell, cracked or crazed lenses, softened plastic, reduced or shifting light output and thermal alarms or trips. Overload, high-resistance joints, a blocked heat path or airflow, a failed fan or dirty filter, and high ambient temperature or direct sun are the usual causes.

What matters is where it sits. A joint with high resistance heats under load current, damages its own insulation and can open the loop. An overloaded isolating transformer, or one run with an open secondary, runs hot and ages its insulation. An LED fixture or driver that runs hot loses output and fails early, and a CCR with blocked cooling may alarm or trip. Heat also ages insulation quietly, so a part can fail later without ever looking badly burnt. The fault returns until its cause is removed, so replacing only the hot part is not enough. Allow equipment to cool and do not assume it is isolated or dead.

  1. Read the symptom. Discoloured insulation, a burnt smell, a cracked or crazed lens, dim or colour-shifted output, or a thermal alarm or trip. A thermal camera, used from a safe distance under the permit while the circuit is still loaded, shows hot joints without contact.
  2. Cool down and isolate. Work under the permit-to-work; allow surfaces to cool; CCR off, locked out and tagged; prove the circuit dead. Never assume a hot part is dead.
  3. Photograph as found. With date and location, and note any readings taken, so the next inspection can show whether it is returning.
  4. Judge what is hot and how far it has gone. A joint, a transformer, a fixture or driver, or a CCR? Marked only, or insulation, lens or housing damaged?
  5. Find the cause. Overload, a poor or corroded joint, a blocked heat path or airflow, a failed fan or filter, or the environment — fix this or it returns.
  6. Act, re-test and record. Critical items first. Repair or replace damaged parts, restore the heat path or airflow, re-test the circuit and log the load and temperature.
Heat that is within design

Equipment is expected to run warm in service. Warm to the touch alone is not a fault; compare with the manufacturer’s limits and with similar units. See heat-management system.

Overheating

Hotter than design allows, with signs such as discolouration, smell, damage, drifting output or a trip. Make safe first, then find the cause.

Definition Heat building up faster than it can leave, so a part runs hotter than designed
Typical signs Discoloured insulation or paint, burnt smell, cracked or crazed lenses, softened plastic, reduced or shifting output, thermal alarms
Typical causes Overload, high-resistance joints, blocked heat path or airflow, failed fan or dirty filter, high ambient or direct sun
Critical places Connections and joints carrying load current, isolating transformers, CCR output stage
Behaviour Progressive: ageing builds up and the fault returns until the cause is removed
Reference ICAO Doc 9157 Pt 5; FAA AC 150/5340-26; manufacturer data
Schematic — simplified and not to scale. Temperature limits and acceptable condition differ between products and sites. Always follow your site’s isolation and permit-to-work procedure and the manufacturer’s instructions; acceptance limits are set by the applicable standard and the maintenance programme.
Entry 12 · Corrosion Entry 14 · Mechanical damage

Frequently Asked Questions

Q1What is overheating in airfield lighting?

Heat building up in a part faster than it can leave, so the part runs hotter than its design allows. It shows as discoloured or darkened insulation and paint, a burnt smell, cracked or crazed lenses, softened or melted plastic, reduced or shifting light output, and thermal trips or alarms.

Q2What causes overheating in airfield lighting equipment?

The usual causes are overload beyond the rating, a high-resistance joint, a blocked heat path or ventilation, a failed fan or dirty filter, and high ambient temperature or direct sun. Corrosion and moisture ingress often sit behind a hot joint, so they are checked together.

Q3What does overheating look like on an LED fixture?

Reduced or flickering output, a colour shift, a discoloured or crazed lens, a darkened housing or gasket, and early driver or LED failure. A poor heat path to the housing, dirt on the heat-sink surface or a failing driver is a common reason.

Q4Why is a hot connection or joint treated as critical?

A joint with high resistance heats up under load current, which discolours or melts the insulation and can open the joint. On a series circuit an open joint breaks the loop, and the heat can damage the insulation around it. Critical items are made safe first.

Q5Why is replacing the hot part not enough?

If the cause stays, the new part overheats too. Find whether it was overload, a poor joint, a blocked heat path or ventilation, or the environment, fix that, then re-test and record the load and temperature so the next inspection can show whether it is returning.

Q6Is it safe to work on equipment that has overheated?

Allow it to cool before touching it, because surfaces may still be hot, and work under the permit-to-work. Do not assume a part is isolated or dead. Isolate, lock out and prove the circuit dead before touching any lead, joint or terminal, and follow the manufacturer's instructions.

Precision AGL Academy

See It. Understand It. Then Learn How to Engineer It.

Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how each light, sign and circuit works as part of a complete airport lighting system, not just as an isolated diagram.

See. Understand. Apply. Engineer.