What is open-circuit protection (OCP)?
A series circuit is one loop, and a constant current regulator will push its set current through whatever it is given. If the loop breaks, open-circuit protection stops the regulator before its voltage climbs, and tells the control system.
Open-circuit protection is the part of a CCR that shuts the output down when the series loop opens. It turns a dangerous no-load condition into a controlled trip and an alarm.
1Why an open circuit is dangerous
A CCR holds a set current. When the loop breaks the current falls to zero, so the CCR raises its output voltage to try to restore it. That voltage climbs toward the CCR's maximum, appears across the break, and stresses insulation, connectors and transformers. It is also a hazard to anyone near the open ends.
2How it is detected
The CCR senses its own output. Little or no current while the output is on, together with a rising voltage, tells the control logic that the loop is open. A short delay avoids tripping on a momentary dip. Thresholds and delays are set by the manufacturer.
3What it does
The CCR opens its output, the lamps go out, and the fault is latched and reported to the control system, often as an open-circuit alarm. The CCR stays tripped until it is reset. A single failed lamp does not do this, because the isolation transformer keeps the primary loop closed and its film cutout shorts the secondary.
4After the trip
The circuit is isolated, locked out and proved dead before work starts, because the cable ends at a break can still be hazardous. The team then splits the loop and tests each section for continuity to find the break, repairs it, and only then resets. Repeated resets apply high voltage to the same fault and can hide the cause.
| Condition | Normal | Open circuit, no OCP | Open circuit, OCP trips |
|---|---|---|---|
| Loop current | Set step value | Falls to zero | Falls to zero, output shut off |
| Output voltage | What the load needs | Climbs toward the CCR maximum | Rises briefly, then removed |
| Lamps | Lit | All out | All out |
| Alarm | None | Only if monitored elsewhere | Open-circuit alarm raised |
| Risk at the break | None | High voltage, arcing | Limited, but isolate and prove dead before work |
Frequently Asked Questions
Q1What does open-circuit protection do?
It shuts the constant current regulator's output down when the series loop is broken. Without it the regulator would keep trying to force the set current through the break, and its output voltage would climb toward its maximum.
Q2Why not just leave the regulator running?
A series circuit is one loop, so a break stops all current. A constant current regulator reacts by raising its voltage to try to restore the current. That puts high voltage across the break and stresses the cable, connectors and transformers, and it is a hazard to anyone near the open ends.
Q3Does a failed lamp trigger it?
No. A lamp sits on the secondary side of its isolation transformer, and the transformer is designed so the primary loop stays closed, with a film cutout shorting the secondary. A single failed lamp dims nothing else and does not open the loop, so it does not trip the protection.
Q4How does the regulator know the circuit is open?
It senses its output. Little or no output current while the regulator is on, together with a rising output voltage, tells the control logic that the loop is open. A short delay avoids tripping on a momentary dip, and the delay and thresholds are set by the manufacturer.
Q5Why should I not keep resetting the regulator after a trip?
The trip means there is a real break somewhere. Each reset applies high voltage to the same fault, which can damage more equipment and hide the cause. The break should be found and repaired before the regulator is reset.
Q6Is the circuit safe once the protection has tripped?
Not automatically. The cable ends at a break can still be hazardous, so the circuit is isolated, locked out and proved dead under the site's procedure before anyone works on it.
See It. Understand It. Then Learn How to Engineer It.
Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.
Build Practical AGL Engineering Skills
Go deeper with structured training from Precision AGL Academy, covering:
Learn how each light, sign and circuit works as part of a complete airport lighting system, not just as an isolated diagram.