What is series circuit voltage?

The voltage a CCR applies across the whole loop — the same current everywhere, with each load and the cable dropping their share.

SERIES LOOP · CIRCUIT VOLTAGE V OUT = V1 + V2 + V3 + V4 + V CABLE CCR V OUT OUT RTN T1 V1 DROP T2 V2 DROP T3 V3 DROP T4 V4 DROP V CABLE I = SAME HERE I = SAME HERE 1 THE SAME CURRENT FLOWS THROUGH EVERY LOAD 2 EACH LOAD AND THE CABLE DROP THEIR SHARE 3 V OUT = THE SUM OF ALL THE DROPS CURRENT THE SAME EVERYWHERE ONE PATH, ONE CURRENT VOLTAGE SHARED OUT: V = I × Z EACH DROP DEPENDS ON ITS OWN Z HAZARD HIGH VOLTAGE, HIGH CURRENT ISOLATE BEFORE ANY WORK SCHEMATIC · LOOP SHORTENED · NOT TO SCALE
series loop (primary cable)
voltage drop across a load or cable
hazard
lamp lit
The Fact Series circuit design

Series circuit voltage is the voltage the CCR applies across the whole loop. In a series circuit the same current flows through every load, so each transformer, fixture and length of cable drops its own share of voltage, equal to the current times its impedance. The shares add up to the CCR output voltage.

Because the CCR holds the current fixed, the voltage is the quantity that changes: it rises when fixtures or cable are added and with each higher brightness step. Both the current and the voltage on the loop are dangerous: several amperes is far above a lethal current and the voltage can be high, so the circuit must be isolated before work. The impedance that sets the voltage is covered under circuit impedance.

  1. Fix the current. Take the current of the brightness step being checked.
  2. Find each drop. Multiply the current by the impedance of each transformer, fixture and cable section.
  3. Add them up. The sum of all the drops is the CCR output voltage (strictly a phasor sum for AC, so a plain addition is an estimate).
  4. Check the CCR. Confirm the voltage, and the resulting kW load, are within the CCR rating.
  5. Check the cable. Confirm the cable and joints are insulated for that voltage.
  6. Use the top step. Repeat at the highest current, where the voltage is greatest.
WhatVoltage the CCR applies across the whole loop
RuleCCR output voltage = sum of all load and cable voltage drops
FormulaV = I × Z total; each drop = I × its own Z
UnitVolts (V), often kV for a whole loop
CurrentFixed by the CCR, same at every point
ReferenceICAO Doc 9157 Pt 5; FAA AC 150/5340-30
Illustrative example only: a loop with a total impedance of 300 Ω needs about 2 kV at 6.6 A, and about 1.2 kV at 4.1 A. Real impedance varies with the step, and actual voltages, limits and cable ratings come from the equipment data sheets and your site’s design basis.
Entry 4 · Series circuit current path Entry 6 · Circuit impedance

Frequently Asked Questions

Q1What is series circuit voltage?

The voltage the CCR applies across the whole loop. It equals the sum of the voltage drops across every load and every length of cable on the circuit.

Q2Why is the current the same everywhere but the voltage different?

A series circuit is a single path, so one current flows through every part of it. Each load and cable section drops a voltage equal to that current times its own impedance, so the drops differ even though the current does not.

Q3What sets the CCR output voltage?

The circuit current multiplied by the total circuit impedance. Adding fixtures or cable raises the impedance, so the CCR has to supply a higher voltage to hold the same current.

Q4Why does the voltage change with the brightness step?

Each brightness step is a different fixed current, and the loop voltage follows the load at that step. The top step normally needs the highest voltage, so the CCR must be able to supply it.

Q5Is the voltage on a series circuit dangerous?

Yes, and so is the current. The loop carries several amperes, far above a lethal current, and the CCR output voltage can be high, which is why the cable is insulated for it. Always isolate and lock out the circuit and follow the site safety procedure before working on it.

Q6What happens to the voltage if the loop opens?

The CCR keeps trying to push its set current through a break, so the voltage rises until its open-circuit protection normally shuts it down. This is why a broken loop is treated as a hazard as well as a lighting fault.

Precision AGL Academy

See It. Understand It. Then Learn How to Engineer It.

Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how each light, sign and circuit works as part of a complete airport lighting system, not just as an isolated diagram.

See. Understand. Apply. Engineer.