The Atlas's closing division — a structured-methodology reference for the analytical techniques that sit above single-fault troubleshooting: 5-Why and fishbone analysis, fault tree analysis by subsystem, FMEA-style severity/frequency/detectability scoring, risk-based prioritisation, and the trend, Pareto, and effectiveness-review techniques that turn individual investigations (Division 23) and preventive actions (Division 27) into a continuously improving engineering programme. Each topic follows a methodology record: purpose → applicable scope → common pitfalls → tools → safety → methodology steps → key outputs → validation criteria → typical findings and actions → programme integration.
Purpose — A structured, iterative questioning technique that traces a failure from its immediate symptom back through successive causes to a systemic root cause, by repeatedly asking "why" against each answer until further questioning stops yielding new, actionable information.
Applicable to single, relatively well-bounded AGL faults (a specific fixture, transformer, or connector failure) where the causal chain is expected to be linear rather than branching; less suited on its own to complex, multi-factor system-level failures.
Read the completed chain back from the final root cause forward to the original symptom and confirm each "why" logically and factually follows from the one before it, with no unsupported leaps, before accepting the analysis as complete.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-HR-01 (Just Culture and Non-Punitive Investigation Procedure)
Standards: ISO 9001:2015 Cl. 10.2, ICAO Doc 9859 (SMS principles)
Diagram: 5-Why Worksheet Template
Case Study: Division 23 — Root Cause Analysis (RCA-561 Human Error Root Cause)
Purpose — A structured cause-and-effect diagramming technique (Ishikawa diagram) that maps every plausible contributing cause of a failure across standard categories — typically Equipment, Process, People, Materials, Environment, and Measurement — to ensure a broad, systematic search rather than following only the first hypothesis that comes to mind.
Applicable to failures with multiple, potentially interacting contributing factors — repeated component failures, circuit-level degradation, or any fault where the cause is not obviously a single linear chain.
Confirm the diagram was populated with genuine causes across multiple categories by a cross-functional group, and that the leading candidates identified were subsequently tested against physical or data evidence before the RCA was closed.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure)
Standards: ISO 9001:2015 Cl. 10.2
Diagram: Fishbone (Ishikawa) Diagram Template — 6M Category Structure
Case Study: Division 23 — Root Cause Analysis (all topics use fishbone branching in the investigation procedure)
Purpose — A deductive, top-down logic-diagram technique that starts from a defined CCR-level failure (the "top event") and systematically breaks it down through AND/OR logic gates into the combinations of lower-level equipment, protection, and human-factor events that could cause it.
Constant Current Regulators (transformer-type and TSCR/inverter-type), their protection relays, power supply, and the human/procedural events that interact with them (e.g., an unresolved trip being reset without investigation).
Cross-check the completed tree against actual CCR trip/failure history to confirm the identified dominant cut sets are consistent with observed failure patterns, and have the tree reviewed and signed off by a cross-functional team before use.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-CCR-04 (CCR LOTO Procedure)
Standards: IEC 61025 (fault tree analysis), ICAO Annex 14 Vol I
Diagram: CCR Fault Tree Diagram
Case Study: Division 23 — Root Cause Analysis (RCA-547 Repeated CCR Trip RCA)
Purpose — A top-down logic-diagram technique applied to a series-circuit-level failure (e.g., "multiple lights dark on Circuit X"), decomposing the top event through AND/OR gates into the cable, transformer, connector, CCR, and earthing basic events that could combine to produce it.
Complete series circuits — CCR output, primary series cable loop, all transformers and fixtures on the loop, and the earthing system supporting it.
Cross-check the dominant cut set identified by the tree against the actual insulation resistance test pattern and fault-location result from the current investigation, confirming the tree correctly predicted where the fault would be found.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-RCL-02 (Series Circuit Fault Location Procedure)
Standards: IEC 61025, ICAO Annex 14 Vol I, FAA AC 150/5340-30
Diagram: Series Circuit Fault Tree Diagram
Case Study: Division 23 — Root Cause Analysis (RCA-558 Repeated Circuit Failure RCA)
Purpose — A top-down logic-diagram technique applied to isolation transformer failure, decomposing the top event (e.g., "transformer open/short circuit") through AND/OR gates into the design, material, environmental, and workmanship basic events that could combine to produce it.
L-830 series-circuit isolation transformers and their base-can environment, wattage/tap specification, and installation/maintenance history.
Cross-check the dominant cut set identified by the tree against the physical teardown findings from the current failed unit, confirming the tree correctly anticipated the observed failure signature.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-RCL-12 (Transformer Test and Replacement Procedure)
Standards: IEC 61025, FAA AC 150/5345-26, IEEE C57.12.91
Diagram: Transformer Fault Tree Diagram
Case Study: Division 23 — Root Cause Analysis (RCA-546 Repeated Transformer Failure RCA)
Purpose — A top-down logic-diagram technique applied to primary or secondary cable failure, decomposing the top event (e.g., "cable insulation breakdown at a specific segment") through AND/OR gates into the environmental, mechanical, electrical, and workmanship basic events that could combine to produce it.
L-824 primary series cable and secondary cable, including duct banks, pull boxes, and field splices along the route.
Cross-check the dominant cut set identified by the tree against the actual TDR/fault-location result from the current investigation, confirming the segment predicted matches the segment found.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-RCL-02 (Series Circuit Fault Location Procedure)
Standards: IEC 61025, IEC 60364, ICAO Annex 14 Vol I
Diagram: Cable Route Fault Tree Diagram
Case Study: Division 23 — Root Cause Analysis (RCA-548 Repeated Cable Failure RCA, RCA-555 Repeated Insulation Failure RCA)
Purpose — A top-down logic-diagram technique applied to complete fixture failure, decomposing the top event (e.g., "fixture fails to illuminate") through AND/OR gates into the transformer, connector, lamp/LED, housing/seal, and physical-damage basic events that could combine to produce it.
Complete inset or elevated AGL fixture assemblies — housing, optics, lamp/LED module, transformer, connector, and base can.
Cross-check the dominant cut set identified by the tree against the physical inspection findings from the current failed fixture, confirming the tree correctly anticipated the observed failure mode.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-RCL-03 (Fixture Replacement Procedure)
Standards: IEC 61025, FAA AC 150/5345-46 (L-852), ICAO Annex 14 Vol I
Diagram: Fixture Fault Tree Diagram (with Transformer Sub-Tree)
Case Study: Division 23 — Root Cause Analysis (RCA-550 Repeated Fixture Failure RCA)
Purpose — A top-down logic-diagram technique applied to illuminated sign failure, decomposing the top event (e.g., "sign panel dark or internal fault") through AND/OR gates into the light source/driver, housing/seal, ventilation/cooling, and structural basic events that could combine to produce it.
L-858 illuminated taxiway/runway guidance signs — housing, door seal, internal light source/driver, panel assembly, and ventilation provision.
Cross-check the dominant cut set identified by the tree against the internal inspection findings from the current failed sign, confirming the tree correctly anticipated the observed failure mode.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-SGN-01 (Illuminated Sign Maintenance Procedure)
Standards: IEC 61025, FAA AC 150/5345-44 (L-858 signs), ICAO Annex 14 Vol I
Diagram: Sign Fault Tree Diagram
Case Study: Division 23 — Root Cause Analysis (RCA-552 Repeated Sign Failure RCA)
Purpose — The systematic process of enumerating every distinct way a specific AGL component, assembly, or system can fail — the first and foundational step of an FMEA (Failure Mode and Effects Analysis) — performed before any severity, frequency, or detectability scoring is attempted.
Applicable at any level — component (transformer, connector), assembly (fixture), or system (circuit, CCR) — and typically performed as a structured team exercise for a defined scope.
Cross-check the completed failure mode list against the internal RCA and preventive-topic records to confirm every previously documented mode is captured, with no unexplained gaps.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-DESIGN-01 (Design Calculation and Review Procedure)
Standards: IEC 60812 (FMEA), SAE J1739 (potential failure mode and effects analysis)
Diagram: FMEA Worksheet Template
Case Study: Division 23 — Root Cause Analysis; Division 27 — Preventive Troubleshooting
Purpose — The process of organising an enumerated list of failure modes (AEI-689) into meaningful categories — by mechanism (electrical, mechanical, thermal, environmental), by subsystem, by detectability, or by criticality — to support pattern recognition, targeted prevention, and prioritised engineering attention.
Applicable to the failure mode inventory across any AGL component, assembly, or system already enumerated via failure mode identification.
Have a second reviewer independently classify a sample of the failure mode list against the same scheme and confirm agreement, before relying on the classification for further Pareto or trend analysis.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure)
Standards: IEC 60812 (FMEA), ISO 14224 (equipment failure classification, adapted)
Diagram: Failure Mode Classification Taxonomy
Case Study: Division 23 — Root Cause Analysis; Division 27 — Preventive Troubleshooting
Purpose — The structured scoring of how serious the consequence of a given failure mode would be if it occurred — the "S" in an FMEA-style S×O×D risk assessment — covering safety, operational, and regulatory-compliance impact, distinct from how likely the failure is to occur.
Applicable to any failure mode identified via AEI-689, scored against the consequence it would produce for aircraft operations, safety, and regulatory compliance if undetected and uncorrected.
Have a second reviewer independently score a sample of failure modes against the same documented scale and confirm reasonable agreement before the severity data is used for risk prioritisation.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-SMS-01 (Safety Risk Assessment Procedure)
Standards: IEC 60812 (FMEA), ICAO Doc 9859 (Safety Management Manual — risk assessment), ICAO Annex 14 Vol I
Diagram: Severity Scoring Scale and Criteria Table
Case Study: Division 23 — Root Cause Analysis; Division 27 — Preventive Troubleshooting
Purpose — The structured scoring of how often a given failure mode is expected to occur — the "O" (occurrence) in an FMEA-style S×O×D risk assessment — grounded in actual field failure history rather than intuition, distinct from the severity of its consequence.
Applicable to any failure mode identified via AEI-689, scored against its actual or reasonably estimated rate of occurrence across the relevant population (by component, location, or circuit).
Recalculate a sample of frequency scores directly from the underlying CMMS export and confirm they match the recorded score and rate-band assignment before the data is used for risk prioritisation.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-SMS-01 (Safety Risk Assessment Procedure)
Standards: IEC 60812 (FMEA), ISO 14224 (reliability data collection, adapted)
Diagram: Frequency Scoring Scale and Rate-Band Table
Case Study: Division 23 — Root Cause Analysis; Division 21 — Preventive Maintenance Troubleshooting
Purpose — The structured scoring of how likely a given failure mode is to be detected before it produces an operational consequence — the "D" (detection) in an FMEA-style S×O×D risk assessment — reflecting the effectiveness of current inspection, monitoring, and alarm coverage for that specific mode.
Applicable to any failure mode identified via AEI-689, scored against the current PM inspection programme, ALCMS/SCADA monitoring, and any other detection mechanism in place for that mode.
Cross-check a sample of detectability scores against the actual PM checklist and monitoring configuration to confirm the identified detection mechanism genuinely exists and covers the specific failure mode as scored.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-SMS-01 (Safety Risk Assessment Procedure)
Standards: IEC 60812 (FMEA), ICAO Doc 9859
Diagram: Detectability Scoring Scale and PM/Monitoring Coverage Map
Case Study: Division 23 — Root Cause Analysis (RCA-559 Repeated Communication Failure RCA); Division 27 — Preventive Troubleshooting (PRV-629 Preventing CCR False Alarms)
Purpose — The practice of prioritising maintenance, investigation, and preventive-action effort according to combined risk (typically Severity × Occurrence × Detectability, or an equivalent risk matrix) rather than treating every open fault or identified failure mode as equally deserving of immediate, equal attention.
Applicable across the entire AGL system — used to sequence which faults get investigated first, which failure modes receive PM programme enhancement first, and which preventive actions are funded first when resources are limited.
Review the current prioritised backlog against the underlying S×O×D data to confirm the ranking is mathematically consistent, and confirm actual resource allocation over the period followed the documented ranking (or that any deviation is explicitly justified).
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-SMS-01 (Safety Risk Assessment Procedure), SOP-PRV-01 (Preventive Maintenance Procedure)
Standards: IEC 60812 (FMEA), ICAO Doc 9859 (SMS risk management), ISO 55001 (asset management)
Diagram: Risk Matrix / Prioritised Backlog Register
Case Study: Division 23 — Root Cause Analysis; Division 27 — Preventive Troubleshooting
Purpose — The focused analytical technique of identifying, across the full fault history, which specific fault instances represent a genuine repeat of a previously closed issue — at the same location, on the same component type, or with the same failure signature — as distinct from routine, generally distributed maintenance activity.
Applicable across the CMMS/FRACAS fault history field-wide, cross-referenced by location, component ID/batch, and failure-mode classification (from AEI-690).
Spot-check the CMMS query results against a manually reviewed sample of the fault history to confirm the systematic query is correctly identifying genuine recurrences and not missing matches due to inconsistent data entry.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-QA-01 (Work Order Closure and Verification Procedure)
Standards: ISO 9001:2015 Cl. 10.2, ISO 55001
Diagram: Recurrence Query Criteria and Flag Configuration
Case Study: Division 23 — Root Cause Analysis (all "Repeated ___ RCA" topics)
Purpose — The technique of plotting a failure, condition, or performance metric over time — insulation resistance, fault frequency, thermal readings, photometric output — to detect a gradual, directional change before it crosses a threshold and becomes an actual fault, distinct from single-point pass/fail inspection.
Applicable to any AGL parameter with repeated measurement over time — insulation resistance, CCR output, earth-loop resistance, photometric survey results, alignment survey results, connector contact resistance, and fault frequency itself.
Confirm that recent trend reviews have correctly identified any parameter approaching its proactive action threshold, and that the corresponding preventive action was triggered before the hard failure threshold was reached.
SOP: SOP-PRV-01 (Preventive Maintenance Procedure), SOP-TEST-03 (Insulation Resistance Test Procedure), SOP-PHM-01 (Photometric Survey Procedure)
Standards: ISO 55001 (asset management), IEEE 43 (insulation testing practice)
Diagram: Trend Chart Template with Action/Failure Threshold Lines
Case Study: Division 23 — Root Cause Analysis (RCA-555 Repeated Insulation Failure RCA, RCA-556 Repeated Photometry Failure RCA)
Purpose — The application of Pareto (80/20) analysis to the classified AGL failure mode inventory — ranking failure categories by frequency or cumulative risk contribution to identify the small number of categories responsible for the large majority of field failures, focusing engineering and preventive resources accordingly.
Applicable to the field-wide or division-wide classified failure mode data (from AEI-690), typically compiled from CMMS/FRACAS records over a defined analysis period.
Cross-check the top-ranked category in the Pareto chart against a manual review of a sample of the underlying fault records to confirm the classification and count are accurate before the chart is used to justify resource allocation.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-PRV-01 (Preventive Maintenance Procedure)
Standards: ISO 9001:2015 Cl. 9.1 (monitoring, measurement, analysis and evaluation), ISO 55001
Diagram: Pareto Chart Template with Cumulative Percentage Line
Case Study: Division 23 — Root Cause Analysis (all topics); Division 27 — Preventive Troubleshooting
Purpose — The systematic review of a component's or circuit's complete maintenance record — every PM visit, repair, part replacement, and inspection finding over its full service life — to extract patterns, verify maintenance adequacy, and inform investigation, distinct from looking only at the immediate fault at hand.
Applicable to any AGL component, fixture, circuit, or CCR with an accumulated maintenance record in the CMMS, used both during active RCA investigations and as a standalone periodic review activity.
Confirm the compiled history against the CMMS source data for completeness, and confirm any pattern conclusion drawn is supported by genuinely comparable, correctly classified events rather than coincidental unrelated ones.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-QA-01 (Work Order Closure and Verification Procedure)
Standards: ISO 55001 (asset management), ISO 9001:2015 Cl. 7.5 (documented information)
Diagram: Maintenance History Timeline Template
Case Study: Division 23 — Root Cause Analysis (RCA-560 Repeated Maintenance Failure RCA)
Purpose — The structured follow-up review conducted after a corrective action has been implemented, to confirm the action actually eliminated or reduced the specific fault it targeted, rather than assuming effectiveness from the work order being closed.
Applicable to any corrective action taken from a Division 23 RCA, Division 27 preventive topic, or any other fault-response work order, reviewed against the specific fault/failure mode it was intended to address.
Confirm the effectiveness review was completed as a distinct, documented step with a clear conclusion (effective / not effective / inconclusive, pending further time) against the originally defined success criteria.
SOP: SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-QA-01 (Work Order Closure and Verification Procedure)
Standards: ISO 9001:2015 Cl. 10.2 (corrective action effectiveness review is an explicit requirement)
Diagram: Corrective Action Effectiveness Review Template
Case Study: Division 23 — Root Cause Analysis (all topics)
Purpose — The structured follow-up review conducted after a preventive action (Division 27) has been implemented, to confirm it actually reduced the field-wide incidence of the failure mode it targeted, distinct from corrective action effectiveness (AEI-699) which reviews a single fault response rather than a proactive, population-wide measure.
Applicable to any preventive action from Division 27 or any other proactive programme measure (PM checklist change, training update, design standard revision), reviewed against the field-wide failure mode frequency it was intended to reduce.
Confirm the effectiveness conclusion is supported by a genuine before/after comparison using consistent data sources and methodology, with adoption verified across the intended population, before the preventive action is considered validated.
SOP: SOP-PRV-01 (Preventive Maintenance Procedure), SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-QA-01 (Work Order Closure and Verification Procedure)
Standards: ISO 9001:2015 Cl. 9.1/10.2, ISO 55001 (asset management)
Diagram: Preventive Action Effectiveness Review Template
Case Study: Division 27 — Preventive Troubleshooting (all topics); Division 23 — Root Cause Analysis
Quick answers about Division 30 — Advanced RCA / Engineering Investigation in the AGL Troubleshooting Atlas.
Division 30 is the Advanced RCA / Engineering Investigation reference. It publishes 20 diagnostic topics, AEI-681 to AEI-700, in a single subsection.
Every topic follows the same diagnostic record: the symptom, equipment/system, possible causes ranked by likelihood (high, medium or low), required tools, safety precautions, diagnostic procedure, test points, root cause verification, corrective action, preventive action and related references (SOPs, standards, diagrams and case studies).
The 20 topics are AEI-681 to AEI-700: 5-Why Analysis for AGL Failure; Fishbone Analysis for AGL Failure; Fault Tree Analysis for CCR Failure; Fault Tree Analysis for Series Circuit Failure; Fault Tree Analysis for Transformer Failure; Fault Tree Analysis for Cable Failure; Fault Tree Analysis for Fixture Failure; Fault Tree Analysis for Sign Failure; Failure Mode Identification; Failure Mode Classification; Failure Severity Assessment; Failure Frequency Assessment; Failure Detectability Assessment; Risk-Based Troubleshooting; Recurrence Analysis; Trend Analysis; Failure Pareto Analysis; Maintenance History Analysis; Corrective Action Effectiveness; Preventive Action Effectiveness.
Each procedure starts with observation before any intervention. For example, AEI-681 (5-Why Analysis for AGL Failure) begins: State the problem precisely and factually — the specific fault, location, and date — rather than a vague or generalised description.
Each topic lists its own precautions. For example, AEI-681 (5-Why Analysis for AGL Failure) starts with: Conduct any interview involved in the analysis in a non-punitive, just-culture manner.
Related references in the topics include SOP-RCA-01 (Root Cause Analysis and FRACAS Procedure), SOP-HR-01 (Just Culture and Non-Punitive Investigation Procedure), SOP-CCR-04 (CCR LOTO Procedure), SOP-RCL-02 (Series Circuit Fault Location Procedure), SOP-RCL-12 (Transformer Test and Replacement Procedure), SOP-RCL-03 (Fixture Replacement Procedure), SOP-SGN-01 (Illuminated Sign Maintenance Procedure) and SOP-DESIGN-01 (Design Calculation and Review Procedure), and 5 more.
Where a standard applies, it appears in the topic's Related References. Those cited in this division include ISO 9001:2015 Cl. 10.2, ICAO Doc 9859, IEC 61025, ICAO Annex 14 Vol I, FAA AC 150/5340-30, FAA AC 150/5345-26, IEEE C57.12.91, IEC 60364, FAA AC 150/5345-46 and FAA AC 150/5345-44, among others.
Use the search box at the top of the page to filter the 20 published topics by code, fault name or keyword; matching topics open automatically. Each diagnostic record can also be downloaded as a Word (.doc) file.
Advanced root cause analysis goes beyond fixing a fault — it changes design, procedure, or maintenance practice so the failure mode doesn't return.
Build the technical knowledge to understand engineering-level failure investigation, systemic reliability analysis, and how to turn a root cause finding into a lasting design or process improvement.
Diagnose systematically. Understand the circuit. Build real AGL expertise.
Please read before relying on any content on this page or on any record downloaded from it.