Division 11 of 25 · Failure Database

PAPI / APAPI Failures

The dedicated failure-classification section for Precision Approach Path Indicator (PAPI) and Abbreviated PAPI (APAPI) systems — covering not only PAPI hardware failures, but also the alignment, elevation, azimuth, beam-angle and photometric failures that can leave a PAPI unit technically energized yet operationally incorrect. “Light is ON” does not necessarily mean “PAPI is performing correctly.”

22 / 22
Topics Published
PAF-01 → 22
Failure ID Range
6 Groups
Equipment · Electrical · Optical/Alignment · Structural · Control · Performance
Rev 0
Initial Issue

Key principle — Division 11 separates equipment failure from guidance-performance failure. A PAPI can be energized and apparently operational while its optical alignment or photometric output has already deteriorated. Every record should answer: what failed → how did it fail → why did it fail → what evidence confirmed it → what was the effect on approach guidance → how was it corrected → how can recurrence be prevented?

Division 11 · PAPI / APAPI Failure Topics

22 of 22 topics published
A
PAPI/APAPI Equipment Failures
2 topics
PAF-01 PAPI Unit Failure
Failure Definition

Failure of a complete PAPI unit resulting in loss of its intended lighting or indication function.

Possible Causes
  • Lamp/LED failure
  • Driver failure
  • Power-supply failure
  • Internal wiring failure
  • Optical failure
  • Moisture ingress
  • Control failure
  • Mechanical damage
Possible Consequences
  • Loss of one PAPI unit
  • Incorrect PAPI indication
  • Reduced system availability
  • Photometric non-compliance
Investigation
  • Unit power
  • Lamp/LED condition
  • Driver
  • Internal wiring
  • Optical system
  • Alignment
  • Housing/sealing
  • Photometric output
PAF-02 APAPI Unit Failure
Failure Definition

Failure of an APAPI unit resulting in loss or degradation of the APAPI indication.

Investigation

Use the same basic failure path as PAPI (PAF-01), while recording the specific APAPI configuration.

Possible Consequences
  • Loss of indication
  • Incorrect indication
  • Intermittent operation
  • Reduced approach guidance reliability
B
Electrical & Component Failures
6 topics
PAF-03 Lamp Failure
Failure Definition

Failure or burnout of the lamp used in a PAPI/APAPI lighting unit.

Possible Causes
  • Lamp burnout
  • End-of-life
  • Overheating
  • Electrical supply problem
  • Driver/power problem
Consequences
  • Reduced light output
  • Unit failure
  • Incorrect indication
  • Photometric degradation
PAF-04 LED Failure
Failure Definition

Failure of the LED light source within an LED-based PAPI/APAPI unit.

Possible Causes
  • LED degradation
  • Thermal stress
  • Electrical damage
  • Driver failure
  • Ageing
Consequences
  • Reduced intensity
  • Incorrect optical output
  • Unit failure
  • Photometric-performance degradation
PAF-05 Driver Failure
Failure Definition

Failure of the electronic driver controlling the lamp/LED light source.

Possible Symptoms
  • No light output
  • Reduced output
  • Flickering
  • Intermittent operation
  • Incorrect intensity
Investigation
POWER SUPPLYDRIVERLED/LAMPOPTICAL OUTPUT
PAF-06 Power-Supply Failure
Failure Definition

Loss or abnormality of the electrical supply required for PAPI/APAPI operation.

Possible Causes
  • Supply interruption
  • Protection trip
  • Power-supply component failure
  • Cable fault
  • Connector fault
Consequences
  • Complete unit outage
  • Intermittent operation
  • Reduced availability
PAF-07 Cable Failure
Failure Definition

Failure of cabling supplying or controlling PAPI/APAPI equipment.

Possible Failure Modes
  • Open circuit
  • Short circuit
  • Insulation breakdown
  • Earth fault
  • Mechanical damage
  • Water ingress
Investigation
  • Cable continuity
  • Insulation
  • Terminations
  • Routing
  • Physical condition
Cross-Reference

Cross-reference with Division 02 — Electrical Failures and Division 05 — Cable & Connector Failures where applicable.

PAF-08 Connector Failure
Failure Definition

Failure of electrical connectors associated with the PAPI/APAPI system.

Possible Failure Modes
  • Loose connector
  • Poor contact
  • Corrosion
  • Moisture ingress
  • High contact resistance
  • Locking failure
Consequences
  • Intermittent operation
  • Reduced output
  • Complete unit failure
Cross-Reference

Cross-reference with Division 05 — Cable & Connector Failures.

C
Optical & Alignment Failures
6 topics
PAF-09 Optical-Window Contamination
Failure Definition

Contamination of the optical window that affects light transmission or beam quality.

Possible Contaminants
  • Dust
  • Sand
  • Mud
  • Water deposits
  • Salt
  • Other environmental contamination
Consequences
  • Reduced intensity
  • Distorted optical performance
  • Photometric degradation
  • Incorrect visual indication
Investigation
  • Optical window
  • External surface
  • Internal surface where applicable
  • Contamination type
  • Cleaning condition
PAF-10 Optical Damage
Failure Definition

Physical damage or deterioration of optical components affecting the PAPI/APAPI beam.

Possible Causes
  • Impact
  • Thermal damage
  • Improper cleaning
  • Environmental deterioration
  • Mechanical movement
Consequences
  • Beam distortion
  • Reduced intensity
  • Incorrect indication
  • Photometric non-compliance
PAF-11 Alignment Error
Failure Definition

PAPI/APAPI unit is not correctly aligned according to the applicable installation/alignment requirement.

Possible Causes
  • Incorrect installation
  • Mechanical movement
  • Foundation settlement
  • Impact
  • Maintenance error
Consequences
  • Incorrect approach guidance
  • Beam-angle deviation
  • Incorrect PAPI indication
Investigation

Verify unit orientation, elevation, azimuth, reference datum and alignment condition.

PAF-12 Elevation Error
Failure Definition

Incorrect vertical/elevation positioning of a PAPI/APAPI unit or its optical reference.

Possible Causes
  • Incorrect installation
  • Foundation settlement
  • Structural movement
  • Incorrect adjustment
Consequences
  • Incorrect approach path indication
  • Beam-angle deviation
  • Incorrect transition between indications
Investigation

Compare actual elevation against the approved/required reference.

PAF-13 Azimuth Error
Failure Definition

Incorrect horizontal orientation of a PAPI/APAPI unit.

Possible Causes
  • Fixture movement
  • Incorrect installation
  • Foundation movement
  • Mechanical impact
  • Incorrect maintenance adjustment
Consequences
  • Incorrect lateral guidance
  • Beam misalignment
  • Reduced approach guidance accuracy
PAF-14 Beam-Angle Deviation
Failure Definition

The actual PAPI/APAPI beam angle deviates from the intended/required beam-angle setting.

Possible Causes
  • Elevation error
  • Azimuth error
  • Optical damage
  • Mechanical movement
  • Incorrect adjustment
  • Foundation settlement
Consequences
  • Incorrect visual approach guidance
  • Incorrect PAPI indication
  • Photometric/alignment non-compliance
Important Distinction

Alignment error (PAF-11) describes the physical alignment condition. Beam-angle deviation describes the resulting optical/angular performance. Both can therefore be recorded in the same failure chain.

D
Structural & Environmental Failures
3 topics
PAF-15 Structural Movement
Failure Definition

Physical movement of the PAPI/APAPI structure or mounting arrangement from its intended position.

Possible Causes
  • Mechanical impact
  • Foundation movement
  • Loose mounting
  • Environmental loading
  • Structural deterioration
Consequences
  • Alignment error
  • Elevation error
  • Azimuth error
  • Beam-angle deviation
Failure Chain
STRUCTURAL MOVEMENTALIGNMENT CHANGEBEAM-ANGLE DEVIATIONINCORRECT INDICATION
PAF-16 Foundation Settlement
Failure Definition

Movement or settlement of the foundation supporting the PAPI/APAPI installation.

Possible Causes
  • Ground movement
  • Poor foundation condition
  • Water-related deterioration
  • Civil-interface problems
Consequences
  • Elevation change
  • Alignment error
  • Structural movement
  • Beam-angle deviation
Investigation
  • Foundation
  • Surrounding pavement/ground
  • Mounting
  • Elevation
  • Alignment
  • Drainage condition
Cross-Reference

Cross-reference with Division 06 — Mechanical & Structural Failures where appropriate.

PAF-17 Moisture Ingress
Failure Definition

Entry of moisture into the PAPI/APAPI unit or associated electrical/optical components.

Possible Consequences
  • Corrosion
  • Electrical leakage
  • Short circuit
  • Optical contamination
  • Driver failure
  • Internal wiring failure
Investigation
  • Housing
  • Seals
  • Cable entries
  • Optical compartment
  • Internal components
  • Condensation evidence
Cross-Reference

Cross-reference with Division 09 — Environmental Failures.

E
Control & Operational Failures
4 topics
PAF-18 Internal Wiring Failure
Failure Definition

Failure of internal electrical wiring within a PAPI/APAPI unit.

Possible Failure Modes
  • Open circuit
  • Loose connection
  • Short circuit
  • Damaged conductor
  • Terminal failure
Consequences
  • Unit outage
  • Intermittent operation
  • Incorrect indication
  • Driver/light-source failure
PAF-19 Communication / Control Failure
Failure Definition

Failure of the communication or control function associated with PAPI/APAPI equipment where such functionality is provided.

Possible Causes
  • Communication loss
  • Control-module failure
  • Wiring failure
  • Network/control-system issue
  • Configuration problem
Consequences
  • Loss of remote control
  • Incorrect operating state
  • Alarm/status problems
  • Intermittent operation
Cross-Reference

Cross-reference with Division 07 — Control System Failures where applicable.

PAF-20 Incorrect PAPI Indication
Failure Definition

PAPI/APAPI provides an indication that does not correctly represent the intended approach-path condition.

Possible Manifestations
  • Incorrect colour indication
  • Incorrect transition
  • Unexpected indication
  • Inconsistent indication between units
Possible Causes
  • Alignment error
  • Elevation error
  • Azimuth error
  • Beam-angle deviation
  • Optical damage
  • Light-source failure
  • Incorrect intensity
  • Structural movement
Investigation

Determine whether the incorrect indication is caused by:

ELECTRICAL FAILUREOPTICAL FAILUREALIGNMENT FAILURESTRUCTURAL FAILURECONTROL FAILURE
PAF-21 Intermittent PAPI Operation
Failure Definition

PAPI/APAPI operation repeatedly becomes unavailable or abnormal and subsequently returns to normal without a stable permanent correction.

Possible Causes
  • Loose connection
  • Driver instability
  • Power-supply problem
  • Internal wiring
  • Communication/control problem
  • Thermal effects
  • Moisture
Investigation — Record
  • Time of occurrence
  • Duration
  • Frequency
  • Environmental conditions
  • Alarm history
  • Equipment condition
  • Maintenance history
F
Performance Failure
1 topic
PAF-22 Photometric-Performance Degradation
Failure Definition

PAPI/APAPI continues to operate but its measured optical performance deteriorates from the required/expected condition.

Possible Causes
  • Lamp ageing
  • LED degradation
  • Optical contamination
  • Optical damage
  • Incorrect alignment
  • Beam-angle deviation
  • Driver degradation
  • Environmental exposure
Possible Consequences
  • Reduced intensity
  • Incorrect beam characteristics
  • Reduced visual effectiveness
  • Non-compliance with applicable performance requirements
Investigation

Where applicable, compare:

PREVIOUS MEASUREMENTCURRENT MEASUREMENTREQUIRED CRITERIONDEVIATIONTREND
Note

This category is particularly important because a PAPI can be energized and apparently operational while its performance has already deteriorated.

No topics match your search.

Division-Wide Requirements

Standard record structure, failure-chain relationships, diagnostic matrix, RCA hierarchy, RCA linkage, evidence layer and severity scheme that apply across all 22 Division 11 failure topics.

A. Recommended Division 11 Failure Record

Every Division 11 failure should ideally be converted into a standard failure record with the following fields:

Identification

  • Failure ID
  • Airport
  • Runway
  • PAPI/APAPI Designation
  • Unit Number
  • Location
  • Date/Time

Technical Condition

  • Failure Category
  • Failure Mode
  • Affected Component
  • Electrical Condition
  • Optical Condition
  • Mechanical Condition
  • Environmental Condition

Alignment

  • Elevation Condition
  • Azimuth Condition
  • Beam-Angle Condition
  • Alignment Measurement
  • Previous Alignment Result

Photometry

  • Measured Performance
  • Required Performance
  • Deviation
  • Previous Measurement
  • Performance Trend

RCA

  • Immediate Cause
  • Failure Mechanism
  • Contributing Factor
  • Root Cause

Corrective Action

  • Repair/Replacement
  • Alignment Correction
  • Optical Cleaning/Repair
  • Structural/Civil Correction
  • Electrical Correction
  • Control Correction

Verification & Reliability

  • Functional Test
  • Alignment Verification
  • Photometric Verification
  • Final Acceptance
  • Return-to-Service Date
  • Previous Occurrence
  • Repeat Failure
  • Downtime
  • Preventive Action
  • Lessons Learned

B. Failure-Chain Relationships

Division 11 becomes much more valuable when the database captures relationships between failure modes rather than treating each as isolated.

Chain 1 — Alignment
FOUNDATION SETTLEMENTSTRUCTURAL MOVEMENTELEVATION ERRORBEAM-ANGLE DEVIATIONINCORRECT PAPI INDICATIONAPPROACH-GUIDANCE DEGRADATION
Chain 2 — Optical
DUST/SALT CONTAMINATIONOPTICAL-WINDOW CONTAMINATIONREDUCED OPTICAL TRANSMISSIONPHOTOMETRIC-PERFORMANCE DEGRADATIONPOTENTIAL INCORRECT VISUAL INDICATION
Chain 3 — Electrical
POWER-SUPPLY FAILUREDRIVER UNAVAILABLELED/LAMP OUTPUT FAILUREPAPI UNIT FAILUREINCORRECT PAPI INDICATION
Chain 4 — Moisture
ENVIRONMENTAL MOISTUREMOISTURE INGRESSINTERNAL CORROSIONINTERNAL WIRING/DRIVER FAILUREINTERMITTENT PAPI OPERATION
Chain 5 — Maintenance/Installation
INCORRECT ALIGNMENT DURING MAINTENANCEALIGNMENT ERRORBEAM-ANGLE DEVIATIONINCORRECT PAPI INDICATIONPOTENTIAL APPROACH-GUIDANCE ISSUE

C. PAPI/APAPI Failure Diagnostic Matrix

No.FailurePrimary Investigation
1PAPI unit failureComplete unit condition
2APAPI unit failureAPAPI unit condition
3Lamp failureLamp/output
4LED failureLED/output
5Driver failureDriver/input/output
6Power-supply failureSupply path
7Cable failureCable continuity/insulation
8Connector failureConnection/contact
9Optical-window contaminationOptical condition
10Optical damageOptical component condition
11Alignment errorOverall alignment
12Elevation errorVertical reference
13Azimuth errorHorizontal reference
14Beam-angle deviationOptical/angular performance
15Structural movementPhysical stability
16Foundation settlementCivil/foundation condition
17Moisture ingressSealing/internal condition
18Internal wiring failureInternal electrical circuit
19Communication/control failureControl/communication
20Incorrect PAPI indicationIndication verification
21Intermittent PAPI operationRecurrence/intermittency
22Photometric-performance degradationPhotometric measurement/trend

D. PAPI RCA Hierarchy

For PAPI/APAPI, the database distinguishes between equipment failure and guidance-performance failure. For example:

EQUIPMENT-LEVEL: LED FAILURE UNIT-LEVEL: PAPI UNIT FAILURE OPTICAL-LEVEL: REDUCED OPTICAL OUTPUT PERFORMANCE-LEVEL: PHOTOMETRIC-PERFORMANCE DEGRADATION OPERATIONAL-LEVEL: INCORRECT PAPI INDICATION / DEGRADED APPROACH GUIDANCE

This distinction is important because “light is ON” does not necessarily mean “PAPI is performing correctly.”

E. RCA Connection

Division 11 links every failure to the Root Cause Analysis Database. The most relevant RCA categories for PAPI/APAPI failures are:

ElectricalThermalOpticalAlignmentMechanicalStructuralEnvironmentalInstallationMaintenanceDesignManufacturingComponentHumanProceduralUnknown/Pending

F. Failure Severity

Every failure receives a severity classification, plus operational-impact tagging:

Critical / Safety-Critical — immediate operational or safety risk

Major / Operationally Critical — significant availability impact

Moderate — reduced performance, not yet critical

Minor / Non-Critical — limited or no operational effect

Degradation / Intermittent / Latent — developing or hidden fault

G. Evidence Layer

Visual Evidence

  • PAPI/APAPI unit, housing and lens photographs
  • Optical window, contamination and damage photographs
  • Foundation, mounting and structural-condition photographs

Technical Evidence

  • Elevation, azimuth and beam-angle measurements
  • Photometric test results and intensity readings
  • Electrical test results, alarm history, maintenance and previous alignment/photometric records

Failure Database vs. Troubleshooting Atlas

The Troubleshooting Atlas answers “I have a fault now — how do I diagnose and fix it?” The Failure Database answers “this failure happened — what happened, why, what evidence proves it, what was done, and how do we stop it recurring?” Kept strictly separate, then linked end-to-end, the two form a genuine AGL Failure Intelligence Engine rather than a simple fault list. Division 11 connects directly with Division 01 Lighting Fixture Failures, Division 02 Electrical Failures, Division 05 Cable & Connector Failures, Division 06 Mechanical & Structural Failures, Division 07 Control System Failures, Division 09 Environmental Failures, Division 18 Maintenance-Induced Failures, Division 19 Product & Component Reliability, Division 21 RCA and Division 23 Reliability Trend Analysis.

Frequently Asked Questions

Quick answers about PAPI and APAPI failures, as covered in Division 11 of the AGL Failure Database.

Q1What is Division 11 — PAPI / APAPI Failures in the AGL Failure Database?

Division 11 covers failures of Precision Approach Path Indicator (PAPI) and Abbreviated PAPI (APAPI) systems. It contains 22 published topics (PAF-01 to PAF-22) spanning unit, electrical, optical, alignment, structural, environmental, control and performance failures.

Q2Which PAPI and APAPI failures does Division 11 cover?

PAPI unit failure, APAPI unit failure, lamp, LED, driver, power-supply, cable and connector failure, optical-window contamination, optical damage, alignment, elevation and azimuth error, beam-angle deviation, structural movement, foundation settlement, moisture ingress, internal wiring failure, communication/control failure, incorrect PAPI indication, intermittent PAPI operation and photometric-performance degradation.

Q3How are the 22 PAPI/APAPI topics grouped?

They fall into six groups: PAPI/APAPI Equipment Failures (2 topics), Electrical & Component Failures (6), Optical & Alignment Failures (6), Structural & Environmental Failures (3), Control & Operational Failures (4) and Performance Failure (1).

Q4Does a lit PAPI mean it is performing correctly?

No. The database distinguishes equipment failure from guidance-performance failure because “light is ON” does not necessarily mean “PAPI is performing correctly”. The hierarchy runs from equipment level (for example LED failure) through unit level, optical level (reduced optical output) and performance level (photometric-performance degradation) to operational level (incorrect PAPI indication or degraded approach guidance).

Q5What PAPI failure chains does Division 11 capture?

In the alignment chain, foundation settlement leads to structural movement, elevation error, beam-angle deviation, incorrect PAPI indication and approach-guidance degradation. In the optical chain, dust or salt contamination leads to optical-window contamination and reduced optical transmission.

Q6Where should the investigation start for a PAPI/APAPI failure?

The diagnostic matrix assigns a primary investigation to each topic. PAPI and APAPI unit failures start with complete unit condition, lamp and LED failures with output, driver failure with driver input and output, power-supply failure with the supply path, cable failure with continuity and insulation, and connector failure with connection and contact.

Q7How are failure severity and operational impact classified?

Every failure receives a severity classification, plus operational-impact tagging. The classes are Critical / Safety-Critical (immediate operational or safety risk), Major / Operationally Critical (significant availability impact), Moderate (reduced performance, not yet critical), Minor / Non-Critical (limited or no operational effect), and Degradation / Intermittent / Latent (a developing or hidden fault).

Q8How does the Failure Database differ from the Troubleshooting Atlas?

The Troubleshooting Atlas answers “I have a fault now — how do I diagnose and fix it?” The Failure Database answers “this failure happened — what happened, why, what evidence proves it, what was done, and how do we stop it recurring?” Kept strictly separate, then linked end to end, the two form an AGL Failure Intelligence Engine rather than a simple fault list.

Beyond the Misaligned Beam

DON’T JUST RESET THE ANGLE. UNDERSTAND WHAT SHIFTED IT.

A PAPI or APAPI fault can come from lamp/LED degradation, unit settlement, elevation drift or power supply issues — real troubleshooting means understanding glide path geometry and unit construction well enough to find why the beam moved.

Take that knowledge further with Precision AGL Academy.

Build Practical AGL Troubleshooting Skills

Learn how to connect:

Failure Symptoms System Understanding Investigation Root Cause Corrective Action Verification Recurrence Prevention

Develop structured knowledge across AGL fundamentals, components, electrical systems, testing, photometry, troubleshooting, maintenance and commissioning.

Find the failure. Understand the cause. Build the engineering skill.

Talk to Precision AGL Academy

Follow the Academy