Division 03 of 25 · Failure Database

CCR Failures

The dedicated Constant Current Regulator failure-intelligence section of the AGL Failure Database — covering output regulation, power electronics, cooling, controls, protection, communication, indications, auxiliary supply and load-related problems across 22 failure categories.

22 / 22
Topics Published
CCR-01 → 22
Failure ID Range
6 Groups
Power · Regulation · Indication · Control · Thermal · Operational
Rev 0
Initial Issue

Key principle — A CCR failure should be recorded by the actual failure mode, operating symptom, evidence, root cause and effect on the series circuit — not simply as "CCR failed." Capture three separate levels for every event: Failure Event (what happened), Failure Mode (how it happened) and Root Cause (why it happened).

Diagnostic principle — Events like "CCR shutdown" or "protection trip" are symptoms, not root causes. Always trace the failure chain back to its initiating condition, and establish whether the CCR itself is the source of the problem or whether it is correctly responding to an abnormal connected series-circuit load.

Division 03 · CCR Failure Topics

22 of 22 topics published
A
CCR Output & Power-Control Failures
6 topics
CCR-01 Output Instability
Failure Definition

CCR output is not stable at the commanded operating condition.

Typical Symptoms
  • Output current fluctuates
  • Current does not settle
  • Fixture intensity varies
  • CCR indication continuously changes
  • Repeated alarms
  • Intermittent circuit behaviour
Possible Failure Areas
  • Current-regulation system
  • Thyristor/power electronics
  • Controller
  • Feedback system
  • Internal wiring
  • Load condition
  • Cooling/thermal condition
Investigation — Record
  • Commanded intensity step
  • Actual output current
  • Output-voltage condition
  • Load condition
  • Alarm status
  • CCR temperature
  • Historical behaviour
  • Event/alarm logs
RCA Focus

Determine whether instability originates from the CCR itself or the connected series-circuit load.

CCR-02 Thyristor Failure
Failure Definition

Failure of the CCR power-control thyristor or associated thyristor circuit.

Possible Symptoms
  • No output
  • Incorrect output current
  • Output instability
  • Protection trip
  • Unable to achieve commanded intensity
  • Abnormal current regulation
Investigation — Check
  • Thyristor condition
  • Gate/control signal
  • Power circuit
  • Heat sink
  • Thermal condition
  • Associated protection
  • Controller command
Evidence
  • Fault/alarm indication
  • Test results
  • Damaged component
  • Thermal condition
  • Replacement component details
CCR-03 Cooling-Fan Failure
Failure Definition

Failure of the CCR cooling fan resulting in inadequate heat removal.

Symptoms
  • Increasing internal temperature
  • Fan alarm
  • Over-temperature condition
  • CCR derating
  • CCR shutdown
  • Repeated thermal trips
Possible Causes
  • Fan motor failure
  • Bearing failure
  • Dust contamination
  • Blocked airflow
  • Electrical supply failure
  • Fan-control failure
Investigation — Check
  • Fan operation
  • Fan supply
  • Fan rotation
  • Airflow
  • Filters
  • Temperature
  • Fan alarm
  • Maintenance condition
CCR-04 Controller Failure
Failure Definition

Failure of the CCR control electronics responsible for regulating or controlling CCR operation.

Symptoms
  • Incorrect output
  • No response to commands
  • Incorrect intensity
  • Alarm generation
  • Display/control abnormality
  • Remote/local control failure
Investigation — Check
  • Controller status
  • Control signals
  • Internal connections
  • Firmware/configuration where applicable
  • Auxiliary supply
  • Communication interfaces
  • Output feedback
CCR-05 Protection Trip
Failure Definition

CCR protective function operates and removes or limits output.

Possible Causes
  • Overcurrent
  • Earth fault
  • Over-temperature
  • Internal component fault
  • Abnormal load
  • Electrical transient
  • Protection-system condition
Investigation Principle

Do not treat the protection trip itself as the final root cause. Determine: why did the protection operate?

ABNORMAL LOADEXCESSIVE ELECTRICAL CONDITIONCCR PROTECTION TRIPCIRCUIT OUTAGE
CCR-06 Communication Failure
Failure Definition

Loss of communication between the CCR and its external control/monitoring system.

Symptoms
  • Remote status unavailable
  • CCR not responding to remote commands
  • Communication alarm
  • Incorrect status indication
  • Loss of monitoring
Investigation — Check
  • Communication cable
  • Communication interface
  • Network connection
  • Controller
  • ALCMS interface
  • Configuration
  • Communication logs
Cross-Reference

If the underlying problem is in the wider ALCMS/control network, cross-reference Division 07 — Control System Failures.

B
CCR Regulation & Performance Failures
4 topics
CCR-07 Calibration Drift
Failure Definition

CCR indication or output progressively deviates from its calibrated/reference condition.

Symptoms
  • Actual current differs from indicated current
  • Intensity step does not correspond to expected output
  • Test results differ from historical values
  • Photometric performance changes
Investigation

Compare:

CCR INDICATIONCALIBRATED MEASUREMENTREFERENCE VALUEHISTORICAL TREND
Important Database Information
  • Previous calibration date
  • Current calibration result
  • Deviation
  • Calibration equipment
  • Corrective adjustment
  • Post-calibration result
CCR-08 Output-Current Deviation
Failure Definition

Actual CCR output current differs from the required/commanded value.

Failure Modes
  • Low output
  • High output
  • Unstable output
  • Incorrect step output
Investigation

Record current at each applicable intensity level: commanded step, expected current (reference), actual current (measured), deviation (calculated), load/circuit condition, CCR status (normal/fault) and corrective action.

CCR-09 Current Regulation Failure
Failure Definition

CCR is unable to maintain the required constant-current output.

Symptoms
  • Current continuously changes
  • Incorrect output
  • Fixture intensity variation
  • Protection activation
  • Failure at particular intensity steps
Possible Areas
  • Power-control section
  • Thyristors
  • Controller
  • Feedback
  • Load
  • Internal wiring
  • Thermal condition
Key Distinction

Output-current deviation = measured output differs from expected. Current regulation failure = CCR cannot maintain the required regulated output.

CCR-10 Intensity-Step Failure
Failure Definition

CCR fails to correctly produce one or more commanded intensity levels.

Symptoms
  • Step not available
  • Incorrect current at a particular step
  • Two steps producing similar output
  • Incorrect transition
  • Step-related alarm
Investigation

Test each available intensity level systematically and record commanded step, expected current, actual current, deviation, transition response and alarm status. This should be linked to CCR testing and commissioning records.

C
CCR Indication & Control Failures
4 topics
CCR-11 Alarm Failure
Failure Definition

CCR alarm function fails to correctly detect, generate, display or transmit a fault condition.

Failure Modes
  • Alarm does not appear
  • False alarm
  • Delayed alarm
  • Incorrect alarm
  • Alarm not transmitted remotely
Investigation — Check
  • Alarm input
  • Controller
  • Alarm logic
  • HMI/display
  • Communication
  • Remote monitoring
Importance

An alarm failure can become a latent safety/maintenance problem, because the CCR may have a developing fault without providing the expected warning.

CCR-12 Display Failure
Failure Definition

CCR display/interface fails to correctly present operating or fault information.

Symptoms
  • Blank display
  • Incorrect reading
  • Missing parameter
  • Frozen indication
  • Display communication error
  • Incorrect status indication
Investigation — Check
  • Display unit
  • Auxiliary supply
  • Controller
  • Communication
  • Internal wiring
  • HMI/interface
CCR-13 Remote-Control Failure
Failure Definition

CCR cannot be correctly controlled through the remote-control interface.

Symptoms
  • Remote ON/OFF command not executed
  • Intensity command not executed
  • Wrong intensity selected
  • CCR does not respond
  • Remote status unavailable
Investigation — Check
  • Remote command
  • Communication
  • CCR controller
  • Interface
  • Local/remote selector
  • Command execution
  • Feedback/status
CCR-14 Local-Control Failure
Failure Definition

CCR fails to respond correctly to commands from its local control interface.

Symptoms
  • Local ON/OFF failure
  • Intensity-step failure
  • Selector failure
  • Control buttons not responding
  • Incorrect local indication
Investigation — Check
  • Local control interface
  • Selector switches
  • Controller
  • Internal wiring
  • Auxiliary supply
  • Control logic
D
Internal Electrical & Thermal Failures
5 topics
CCR-15 Internal Wiring Failure
Failure Modes
  • Loose wire
  • Broken conductor
  • Incorrect connection
  • Burnt wire
  • Insulation damage
  • Terminal failure
  • Incorrect routing
Symptoms
  • Intermittent operation
  • Control failure
  • Output instability
  • Alarm failure
  • Complete shutdown
Investigation — Inspect
  • Control wiring
  • Power wiring
  • Terminal blocks
  • Internal connectors
  • Harnesses
  • Signs of heating
CCR-16 Terminal Overheating
Failure Definition

Abnormally high temperature at a CCR electrical terminal or connection.

Possible Causes
  • Loose terminal
  • High contact resistance
  • Excessive current
  • Poor termination
  • Corrosion
  • Incorrect conductor size
  • Thermal deterioration
Failure Progression
LOOSE/POOR CONNECTIONRESISTANCE INCREASESHEATINGTERMINAL DEGRADATIONFAILURE
Evidence
  • Terminal condition
  • Thermal evidence
  • Discolouration
  • Connection tightness
  • Current
  • Cable/terminal rating
  • Corrective action
CCR-17 Auxiliary-Supply Failure
Failure Definition

Loss or degradation of the auxiliary electrical supply required for CCR control, monitoring, cooling or associated functions.

Symptoms
  • CCR control failure
  • Display failure
  • Communication failure
  • Cooling failure
  • Alarm failure
  • CCR shutdown
Investigation — Check
  • Auxiliary input
  • Internal auxiliary supply
  • Fuses/protection
  • Power supply unit
  • Control transformer where applicable
  • Internal wiring
Important RCA Distinction

A CCR may appear to have a controller failure when the actual cause is an auxiliary-supply failure.

CCR-18 Cooling-System Failure
Failure Definition

Failure of the CCR's overall cooling arrangement. This is broader than Cooling-Fan Failure.

Possible Causes
  • Fan failure
  • Blocked airflow
  • Filter contamination
  • Heat exchanger problem
  • Ventilation failure
  • Internal temperature rise
  • Cooling-control failure
Symptoms
  • High internal temperature
  • Reduced performance
  • Thermal alarm
  • Over-temperature
  • Shutdown
Relationship

Cooling-fan failure = specific failure mode. Cooling-system failure = wider system-level condition.

CCR-19 Over-Temperature Condition
Failure Definition

CCR internal temperature exceeds the allowable operating condition.

Causes
  • Cooling failure
  • High ambient temperature
  • Blocked ventilation
  • Fan failure
  • Excessive load
  • Internal component overheating
  • Dust accumulation
Symptoms
  • Temperature alarm
  • Output reduction
  • Protection trip
  • CCR shutdown
  • Component degradation
Investigation — Record
  • Ambient temperature
  • CCR internal temperature
  • Load
  • Fan status
  • Ventilation condition
  • Alarm history
  • Shutdown history
E
CCR Operational & Load Failures
3 topics
CCR-20 CCR Shutdown
Failure Definition

Unintended or fault-induced cessation of CCR operation.

Possible Causes
  • Protection trip
  • Over-temperature
  • Auxiliary-supply failure
  • Controller failure
  • Internal power failure
  • Load-related problem
  • Severe electrical fault
Important Investigation Rule

"CCR shutdown" is the event/symptom. The investigation must identify the actual initiating failure. For example:

CCR SHUTDOWNOVER-TEMPERATURECOOLING-FAN FAILURE

or:

CCR SHUTDOWNPROTECTION TRIPSERIES-CIRCUIT EARTH FAULT
CCR-21 Intermittent CCR Operation
Failure Definition

CCR repeatedly starts, stops or behaves abnormally without remaining continuously failed.

Symptoms
  • Random shutdown
  • Repeated restart
  • Intermittent output
  • Temporary alarms
  • Unstable current
  • Fault disappears after reset
Possible Causes
  • Loose internal connection
  • Thermal problem
  • Controller fault
  • Communication problem
  • Auxiliary supply instability
  • Protection issue
  • Load-related condition
Investigation

This failure requires particularly strong evidence: event logs, alarm history, operating time, temperature, output current, load condition, and the number/timing of occurrences.

CCR-22 Load-Related Failure
Failure Definition

CCR abnormal behaviour caused by the connected AGL series-circuit load rather than an isolated CCR component failure.

Possible Causes
  • Incorrect circuit load
  • Cable fault
  • Earth fault
  • Short circuit
  • Open circuit
  • Transformer problem
  • Fixture failure
  • Excessive load
  • Abnormal circuit condition
Symptoms
  • Output instability
  • Protection trip
  • Current regulation problem
  • CCR shutdown
  • Abnormal output current
Critical Diagnostic Principle

Before replacing a CCR component, establish whether the CCR is actually the source of the problem. A CCR can correctly respond to an abnormal series-circuit condition.

No topics match your search.

Division-Wide Requirements

Diagnostic matrix, failure chains, structured failure record and RCA linkage that apply across all 22 Division 03 CCR failure topics.

A. CCR Failure Diagnostic Matrix

Quick-reference mapping of main symptom to first investigation focus for every Division 03 failure category:

FailureMain SymptomFirst Investigation Focus
Output instabilityFluctuating outputRegulation/load
Thyristor failureIncorrect/no outputPower section
Cooling-fan failureTemperature riseFan/airflow
Controller failureControl abnormalityController/auxiliary supply
Protection tripCCR tripsDetermine initiating fault
Communication failureRemote status/control lostInterface/network
Calibration driftMeasurement deviationCalibration
Output-current deviationWrong currentMeasurement/regulation
Current regulation failureCannot maintain currentFeedback/power/load
Intensity-step failureWrong step outputStep-control system
Alarm failureFault not indicatedAlarm logic/interface
Display failureWrong/no displayDisplay/auxiliary supply
Remote-control failureRemote command failsControl interface
Local-control failureLocal command failsLocal interface
Internal wiring failureIntermittent/control faultInternal connections
Terminal overheatingHot terminalConnection/current
Auxiliary-supply failureMultiple control functions lostAuxiliary supply
Cooling-system failureThermal problemsComplete cooling path
Over-temperatureHigh temperatureCooling/load
CCR shutdownCCR stopsIdentify initiating fault
Intermittent operationRandom faultLogs/thermal/connections
Load-related failureCCR reacts abnormally to circuitSeries-circuit condition

B. CCR Failure Chain Examples

Record the failure chain, not just the final symptom.

Example 1 — Cooling
COOLING-FAN FAILURECOOLING-SYSTEM DEGRADATIONCCR OVER-TEMPERATUREPROTECTION OPERATIONCCR SHUTDOWNAGL CIRCUIT OUTAGE
Example 2 — Series Circuit
CABLE INSULATION PROBLEMEARTH FAULTCCR PROTECTION TRIPCCR SHUTDOWNLIGHTING OUTAGE

Here, CCR shutdown is not the root cause. The initiating failure is the electrical fault in the series circuit.

Example 3 — Internal Connection
LOOSE CCR TERMINALHIGH-RESISTANCE CONNECTIONTERMINAL OVERHEATINGINTERNAL WIRING/TERMINAL DAMAGECCR OUTPUT INSTABILITYPOSSIBLE CCR SHUTDOWN

C. Recommended Database Rule

For every CCR event, capture three separate levels:

Failure Event: What happened? — CCR shutdown

Failure Mode: How did it happen? — Over-temperature condition

Root Cause: Why did it happen? — Cooling-fan failure / blocked airflow / maintenance deficiency

This separation prevents the CCR database from becoming a simple list of symptoms and allows it to connect properly with Electrical Failures, Control System Failures, Testing & Commissioning, Maintenance-Induced Failures, RCA, Criticality and Reliability Trend divisions.

D. Recommended Division 03 CCR Failure Record

Every CCR failure should have a structured record containing at minimum:

Identification

  • Failure ID
  • Airport/Project
  • CCR Identification
  • Manufacturer
  • Model
  • Rating
  • Circuit Served
  • Installation Date

Failure Information

  • Failure Date/Time
  • Failure Category
  • Failure Mode
  • Symptoms
  • Operating Intensity Step
  • Output Current
  • Output Voltage where applicable
  • CCR Temperature
  • Load Condition
  • Alarm Indication
  • Event-Log Information

Investigation

  • Initial Observation
  • Electrical Test
  • Functional Test
  • Component Inspection
  • Internal Inspection
  • Load/Circuit Verification
  • Evidence Photographs

RCA

  • Immediate Cause
  • Root Cause
  • Contributing Factor
  • Failure Mechanism

Restoration

  • Corrective Action
  • Component Replaced
  • Repair Performed
  • Calibration
  • Functional Test
  • Post-Repair Output Test

Reliability

  • Previous Failure
  • Repeat Failure
  • Operating Hours
  • Downtime
  • Severity
  • Operational Impact
  • Preventive Action
  • Lessons Learned

E. Failure Severity

Every failure receives a severity classification, plus operational-impact tagging:

Critical / Safety-Critical — immediate operational or safety risk

Major / Operationally Critical — significant availability impact

Moderate — reduced performance, not yet critical

Minor / Non-Critical — limited or no operational effect

Degradation / Intermittent / Latent — developing or hidden fault

F. RCA Categories Most Relevant to CCR Failures

Of the source's 18 root-cause categories, the most important for Division 03 are:

ElectricalThermalComponentEnvironmentalInstallationMaintenanceDesignManufacturingMaterialHumanProceduralOperationalCommunicationUnknown/Pending

Division 03 vs. Division 02

Division 02 captures failures in the electrical path feeding the circuit — cable, connector, termination, insulation, protection. Division 03 captures failures within the CCR itself — power electronics, cooling, controls, calibration, indication and auxiliary supply. Where a CCR trips or shuts down, always confirm whether the initiating failure is internal to the CCR (Division 03) or an abnormal series-circuit condition upstream (Division 02) before replacing any CCR component.

Frequently Asked Questions

Quick answers about Constant Current Regulator (CCR) failures, as covered in Division 03 of the AGL Failure Database.

Q1What is Division 03 — CCR Failures in the AGL Failure Database?

Division 03 covers failures within the Constant Current Regulator itself. It contains 22 published topics (CCR-01 to CCR-22) spanning output regulation, power electronics, cooling, controls, protection, communication, indications, auxiliary supply and load-related problems.

Q2Which CCR failures does Division 03 cover?

Output instability, thyristor failure, cooling-fan failure, controller failure, protection trip, communication failure, calibration drift, output-current deviation, current regulation failure, intensity-step failure, alarm failure, display failure, remote-control failure, local-control failure, internal wiring failure, terminal overheating, auxiliary-supply failure, cooling-system failure, over-temperature condition, CCR shutdown, intermittent CCR operation and load-related failure.

Q3How are the 22 CCR topics grouped?

They are grouped into five sets: CCR Output & Power-Control Failures (6 topics), CCR Regulation & Performance Failures (4), CCR Indication & Control Failures (4), Internal Electrical & Thermal Failures (5) and CCR Operational & Load Failures (3).

Q4What three levels should be captured for every CCR event?

Every CCR event should record a failure event (what happened, for example a CCR shutdown), a failure mode (how it happened, for example an over-temperature condition) and a root cause (why it happened, for example cooling-fan failure, blocked airflow or a maintenance deficiency). This keeps the database from becoming a simple list of symptoms.

Q5Is a CCR shutdown a root cause?

No. A CCR shutdown is often a consequence. In one recorded chain, a cable insulation problem causes an earth fault, which causes a CCR protection trip, a CCR shutdown and a lighting outage. Here the initiating failure is the electrical fault in the series circuit, not the CCR.

Q6How do Division 02 and Division 03 differ?

Division 02 covers failures in the electrical path feeding the circuit, such as cable, connector, termination, insulation and protection. Division 03 covers failures within the CCR itself: power electronics, cooling, controls, calibration, indication and auxiliary supply. When a CCR trips or shuts down, confirm whether the initiating failure is internal to the CCR or an abnormal series-circuit condition upstream before replacing any CCR component.

Q7Where should the investigation start for a given CCR symptom?

The diagnostic matrix maps each symptom to a first investigation focus. For example, output instability points to regulation and load, thyristor failure to the power section, cooling-fan failure to fan and airflow, controller failure to the controller and auxiliary supply, communication failure to the interface and network, and a protection trip to determining the initiating fault.

Q8What should be recorded for a CCR failure?

Each record should include identification (failure ID, airport/project, CCR identification, manufacturer, model, rating, circuit served, installation date), failure information (date/time, category, mode, symptoms, intensity step, output current, CCR temperature, load condition, alarm and event-log information), investigation results, evidence and photographs, RCA (immediate cause, root cause, contributing factor, failure mechanism) and restoration details.

Q9How are failure severity and operational impact classified?

Every failure receives a severity classification, plus operational-impact tagging. The classes are Critical / Safety-Critical (immediate operational or safety risk), Major / Operationally Critical (significant availability impact), Moderate (reduced performance, not yet critical), Minor / Non-Critical (limited or no operational effect), and Degradation / Intermittent / Latent (a developing or hidden fault).

Beyond the Alarm

DON’T JUST RESET THE CCR. UNDERSTAND WHY IT TRIPPED.

A CCR fault can come from a thyristor failure, a current-transformer error, a control-logic fault or a downstream circuit problem — real troubleshooting means understanding CCR architecture well enough to trace the alarm back to its actual source.

Take that knowledge further with Precision AGL Academy.

Build Practical AGL Troubleshooting Skills