Constant-current series circuit fault diagnosis — from complete loop failures and current-behaviour anomalies through to cable/insulation integrity faults, voltage and loading irregularities, CCR trip conditions, and faults surfacing after maintenance or component replacement. Each topic follows the full engineering diagnostic record: symptom → observation → measurement → decision → fault location → root cause → verification → corrective action → preventive action.
Symptom — No fixtures on the series circuit loop illuminate when the CCR is running and commanding output, even though the CCR itself may show normal output current/voltage or may be alarming on an open-circuit/output-fail condition.
AGL series circuit loop (constant-current lighting circuit), isolating transformers, field cable, connectors, and the CCR output feed to the loop.
After repair, confirm loop continuity is restored end to end, then run the CCR through a full load cycle and confirm all fixtures illuminate correctly with no repeat open-circuit indication.
SOP: SOP-SC-01 (Series Circuit Loop Testing)
Standards: ICAO Annex 14 Vol I, IEC 61820-3-2 (supersedes IEC 61822)
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — One specific fixture on the series circuit fails to illuminate while all other fixtures on the same loop operate normally at the correct intensity.
Individual fixture, its isolating transformer, and the associated field connector(s) at that fixture position.
After replacement, reconnect and confirm the fixture illuminates correctly at all intensity steps, and re-check adjacent fixtures remain unaffected.
SOP: SOP-SC-02 (Fixture and Transformer Fault Isolation)
Standards: ICAO Annex 14 Vol I
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — More than one, but not all, fixtures on the series circuit fail to illuminate — either scattered across the loop or clustered in one section — while the remaining fixtures operate normally.
Multiple fixtures and isolating transformers across the affected section(s) of the series circuit loop.
After repair, confirm all previously affected fixtures illuminate correctly at all intensity steps through a full load cycle.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-SC-02 (Fixture and Transformer Fault Isolation)
Standards: ICAO Annex 14 Vol I
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — The series circuit, or a group of fixtures on it, intermittently loses illumination and recovers, rather than failing completely or remaining stable — occurrences may correlate with vibration, temperature swings, or weather.
Series circuit loop, connectors, joints, and isolating transformers across the affected section.
After repair, monitor the affected section through a sustained multi-cycle period, ideally spanning the correlated condition (e.g. a rain event), and confirm no recurrence.
SOP: SOP-SC-01 (Series Circuit Loop Testing)
Standards: —
Diagram: Series Circuit Single Line Diagram
Case Study: Division 22 — Intermittent Fault Methodology; Division 25 — Field Case Study Troubleshooting
Symptom — Measured series circuit current is below the commanded intensity step value, and fixtures appear dimmer than expected, even though the CCR appears to be regulating and no fault alarm is present.
Series circuit loop, CCR current feedback path, and loop impedance elements (cable, transformers, connections).
After correction, confirm loop current matches the commanded value at all intensity steps, verified independently, through a full load cycle.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-CCR-02 (CCR Output Verification)
Standards: IEC 61820-3-2 (supersedes IEC 61822)
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — Measured series circuit current exceeds the commanded intensity step value, with fixtures appearing overly bright and at risk of accelerated lamp/transformer wear or damage.
Series circuit loop and CCR current feedback/regulation path.
After correction, confirm loop current matches the commanded value precisely at all intensity steps, verified independently, with no overshoot at step changes.
SOP: SOP-CCR-02 (CCR Output Verification), SOP-CCR-10 (Protection Relay Calibration)
Standards: IEC 61820-3-2 (supersedes IEC 61822)
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — Series circuit current fluctuates or oscillates around the commanded value rather than remaining steady, visible as flickering brightness across the loop or on the CCR's current display/trend.
Series circuit loop, CCR current feedback and control loop, and loop connections.
After repair, monitor loop current continuously through a sustained multi-cycle period and confirm stable regulation with no recurrence of fluctuation.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-CCR-02 (CCR Output Verification)
Standards: —
Diagram: Series Circuit Single Line Diagram
Case Study: Division 22 — Intermittent Fault Methodology; Division 25 — Field Case Study Troubleshooting
Symptom — The series circuit loop shows very high or infinite resistance/no continuity end to end, resulting in zero current and typically an open-loop/output-fail alarm at the CCR.
Series circuit loop — cable, connectors, isolating transformer windings in series through the loop path.
After repair, confirm loop continuity is restored end to end and run the CCR through a full load cycle with no repeat open-circuit alarm.
SOP: SOP-SC-01 (Series Circuit Loop Testing)
Standards: ICAO Annex 14 Vol I, IEC 61820-3-2 (supersedes IEC 61822)
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — The series circuit loop shows an abnormally low resistance between conductors, typically causing the CCR to trip on overcurrent, with possible visible damage (scorching, melted insulation) at the fault location.
Series circuit loop conductors, connectors, and isolating transformer windings.
After repair, re-megger the loop to confirm resistance between conductors meets or exceeds the design minimum, then run the CCR through a full load cycle with no repeat trip.
SOP: SOP-SC-01 (Series Circuit Loop Testing)
Standards: ICAO Annex 14 Vol I, IEC 61820-3-2 (supersedes IEC 61822)
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — The CCR raises an earth fault (ground fault) alarm attributable to this series circuit, indicating leakage current from the loop to earth has exceeded the protection threshold.
Series circuit loop insulation to earth, cable, isolating transformers, and any conductive structures/fixtures the loop passes through or near.
After repair, re-megger the full loop and confirm insulation resistance meets or exceeds the design minimum; run the CCR through a full load cycle with no repeat trip.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-CCR-10 (Protection Relay Calibration)
Standards: ICAO Annex 14 Vol I, IEC 61820-3-2 (supersedes IEC 61822), IS 7785
Diagram: Series Circuit Single Line Diagram, CCR Protection Schematic
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — Routine or investigative insulation resistance testing shows the series circuit loop's insulation has degraded below the acceptable baseline, whether or not this has yet produced an active earth fault trip.
Series circuit loop cable insulation, isolating transformer insulation, and connector/joint insulation across the full loop.
After correction, re-test insulation resistance and confirm it meets or exceeds the design minimum, with the trend re-established against a fresh baseline.
SOP: SOP-SC-01 (Series Circuit Loop Testing)
Standards: IEC 61820-3-2 (supersedes IEC 61822)
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — Measured leakage current on the series circuit loop is elevated above normal but remains below the CCR's full earth fault trip threshold, potentially causing nuisance trips under certain conditions without a hard, permanent fault.
Series circuit loop insulation to earth, cable, and connector/joint condition across the full loop.
After correction, re-measure total loop leakage and confirm it is within the expected range for the installation, with a comfortable margin below the trip threshold.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-CCR-10 (Protection Relay Calibration)
Standards: IEC 61820-3-2 (supersedes IEC 61822)
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — Measured loop resistance, or the resistance of a specific segment, is significantly higher than the as-built/commissioning baseline, even though the circuit may still be operating without an active alarm.
Series circuit loop conductors, connectors, and joints across the full loop or a specific segment.
After correction, re-measure resistance using the same method as the baseline and confirm it returns to within the expected range.
SOP: SOP-SC-01 (Series Circuit Loop Testing)
Standards: —
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — The voltage measured across the series circuit loop, or across a specific segment, is higher than expected for the measured current, indicating excessive voltage drop and requiring the CCR to operate closer to its maximum output voltage compliance.
Series circuit loop — cable, connectors, and isolating transformers contributing cumulative impedance.
After correction, re-measure CCR output voltage at the commanded current and confirm it is consistent with the design voltage-drop calculation, with adequate margin to the CCR's maximum compliance voltage.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-CCR-02 (CCR Output Verification)
Standards: IEC 60364 (voltage drop limits)
Diagram: Series Circuit Voltage Drop Calculation Sheet
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — Voltage measured at a specific point in the series circuit loop is unexpectedly high or low relative to what should be present at that position given the loop's current and the design turns ratios/loading up to that point.
Series circuit loop, isolating transformers, and their turns ratios/tap configuration at the measurement point.
After correction, re-measure voltage at the affected point and confirm it matches the design expectation for the loop's current, and verify no other points on the loop are similarly affected.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-SC-02 (Fixture and Transformer Fault Isolation)
Standards: —
Diagram: Series Circuit Single Line Diagram, Transformer Ratio Schedule
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — The CCR is unable to reach the commanded intensity step current even at its maximum output voltage compliance, resulting in reduced actual intensity, a regulation-fail condition, or an associated CCR alarm.
Series circuit loop total impedance and the CCR's output voltage compliance capability together.
After correction, confirm the CCR reaches the commanded current at all intensity steps with adequate margin below its maximum output voltage compliance.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-CCR-02 (CCR Output Verification)
Standards: IEC 60364 (voltage drop limits), IEC 61820-3-2 (supersedes IEC 61822)
Diagram: Series Circuit Voltage Drop Calculation Sheet
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — The series circuit operates normally at lower intensity steps but trips (typically on earth fault or overcurrent) specifically when stepped to a higher intensity level, and recovers when operated only at lower steps.
Series circuit loop insulation and isolating transformers, which experience higher voltage/flux stress at higher intensity steps.
After repair, operate the circuit at the highest intensity step for a sustained period across multiple cycles and confirm no repeat trip.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-CCR-10 (Protection Relay Calibration)
Standards: IEC 61820-3-2 (supersedes IEC 61822)
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — The series circuit trips (typically on earth fault) specifically during or shortly after rain or wet weather, while operating normally in dry conditions.
Series circuit loop cable joints, connectors, pull boxes, and any below-grade infrastructure exposed to water ingress.
After repair, monitor the circuit through at least one subsequent rain event and confirm no recurrence of the trip.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-CCR-10 (Protection Relay Calibration)
Standards: IEC 61820-3-2 (supersedes IEC 61822)
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — The series circuit trips specifically at the moment of energizing (start-up) or when the CCR commands a step change, but is stable and does not trip once running steadily at a given level.
Series circuit loop and CCR output/protection logic at the moment of switching events.
After correction, perform multiple controlled start-up and step-change cycles and confirm no repeat trip.
SOP: SOP-CCR-10 (Protection Relay Calibration), SOP-SC-01 (Series Circuit Loop Testing)
Standards: IEC 61820-3-2 (supersedes IEC 61822)
Diagram: CCR Protection Schematic
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — The series circuit trips repeatedly at unpredictable times, without a clear correlation to intensity step, weather, or switching events, rather than following one of the more specific recognisable trip patterns.
Series circuit loop, in full — cable, connectors, joints, and isolating transformers across the loop.
Require a minimum of five consecutive successful full-load operating cycles, including under realistic field conditions, before closing out.
SOP: SOP-CCR-06 (Repeated Fault Investigation Procedure), SOP-SC-01 (Series Circuit Loop Testing)
Standards: —
Diagram: —
Case Study: Division 22 — Intermittent Fault Methodology; Division 23 — Root Cause Analysis; Division 25 — Field Case Study Troubleshooting
Symptom — A series circuit fault appears immediately or shortly after a general maintenance activity on the circuit, where the circuit was confirmed working correctly before that activity began.
Series circuit loop and whatever component(s) were the subject of the maintenance activity.
After correction, confirm the circuit operates correctly through a full load cycle and re-verify the specific item(s) corrected.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-CCR-04 (CCR Isolation & LOTO Procedure)
Standards: —
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — A series circuit fault (open circuit, short circuit, earth fault, or elevated leakage) appears specifically following a cable joint/splice repair, at or near the location of the new joint.
The specific cable joint/splice and the cable sections immediately either side of it.
After remaking the joint, re-megger and re-test resistance across it, then run the circuit through a full load cycle, ideally including a subsequent wet-weather check, with no repeat fault.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-SC-03 (Cable Jointing Procedure)
Standards: Manufacturer joint kit installation instructions
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — A series circuit fault, or the newly replaced fixture itself failing to operate correctly, appears immediately after a fixture (light) was replaced, even though the rest of the loop was unaffected before the replacement.
The newly replaced fixture, its isolating transformer, and the connector(s) reconnected during the replacement.
After correction, confirm the fixture illuminates correctly at all intensity steps and re-check that adjacent fixtures and overall loop parameters remain unaffected.
SOP: SOP-SC-02 (Fixture and Transformer Fault Isolation)
Standards: —
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — A series circuit fault appears immediately after an isolating transformer was replaced, affecting either the associated fixture specifically or the wider loop.
The newly replaced isolating transformer and the connectors/leads reconnected during its replacement.
After correction, confirm the associated fixture illuminates correctly and overall loop current/voltage parameters remain within expected values through a full load cycle.
SOP: SOP-SC-02 (Fixture and Transformer Fault Isolation)
Standards: —
Diagram: Series Circuit Single Line Diagram, Transformer Ratio Schedule
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Symptom — A series circuit fault (open circuit, intermittent connection, or earth fault/leakage) appears immediately after a field connector was replaced at a fixture, transformer, or loop joint location.
The newly replaced connector and its immediate connections at both ends.
After correction, confirm the circuit operates correctly through a full load cycle, ideally including a subsequent wet-weather check for connectors exposed outdoors, with no repeat fault.
SOP: SOP-SC-01 (Series Circuit Loop Testing), SOP-SC-02 (Fixture and Transformer Fault Isolation)
Standards: —
Diagram: Series Circuit Single Line Diagram
Case Study: Division 25 — Field Case Study Troubleshooting (cross-reference where applicable)
Quick answers about Series Circuit troubleshooting in the AGL Troubleshooting Atlas.
Division 02 is the Series Circuit Troubleshooting reference. It publishes 25 diagnostic topics, SC-096 to SC-120, across 6 subsections: Series Circuit General Circuit Failures (4); Series Circuit Current Behaviour (3); Series Circuit Integrity Faults (6); Series Circuit Voltage & Loading Behaviour (3); Series Circuit Trip Conditions (4); Series Circuit Post-Maintenance Failures (5).
Every topic follows the same diagnostic record: the symptom, equipment/system, possible causes ranked by likelihood (high, medium or low), required tools, safety precautions, diagnostic procedure, test points, root cause verification, corrective action, preventive action and related references (SOPs, standards, diagrams and case studies).
SC-096 to SC-099 (4 topics): Complete Series Circuit Failure; Single Light Failure; Multiple Light Failure; Intermittent Series Circuit Failure.
SC-100 to SC-102 (3 topics): Circuit Current Too Low; Circuit Current Too High; Circuit Current Unstable.
SC-103 to SC-108 (6 topics): Circuit Open Circuit; Circuit Short Circuit; Circuit Earth Fault; Circuit Insulation Failure; Circuit Leakage Current High; Circuit Resistance Abnormally High.
SC-109 to SC-111 (3 topics): Circuit Voltage Drop Excessive; Unexpected Circuit Voltage; Circuit Cannot Reach Required Current.
SC-112 to SC-115 (4 topics): Circuit Trips at Higher Intensity; Circuit Trips During Rain; Circuit Trips During Switching; Circuit Trips Intermittently.
SC-116 to SC-120 (5 topics): Circuit Failure After Maintenance; Circuit Failure After Cable Jointing; Circuit Failure After Light Replacement; Circuit Failure After Transformer Replacement; Circuit Failure After Connector Replacement.
Each procedure starts with observation before any intervention. For example, SC-096 (Complete Series Circuit Failure) begins: Confirm the CCR is genuinely producing output (measured, not just displayed) at its output terminals before assuming the fault is in the loop.
Each topic lists its own precautions. For example, SC-096 (Complete Series Circuit Failure) starts with: Series circuit voltage can reach several kV under load depending on circuit length — never work on loop terminals while the CCR is running or capacitors are charged.
Related references in the topics include SOP-SC-01 (Series Circuit Loop Testing), SOP-SC-02 (Fixture and Transformer Fault Isolation), SOP-CCR-02 (CCR Output Verification), SOP-CCR-10 (Protection Relay Calibration), SOP-CCR-06 (Repeated Fault Investigation Procedure), SOP-CCR-04 (CCR Isolation & LOTO Procedure) and SOP-SC-03 (Cable Jointing Procedure).
Where a standard applies, it appears in the topic's Related References. Those cited in this division include ICAO Annex 14 Vol I, IEC 61820-3-2, IS 7785 and IEC 60364.
Use the search box at the top of the page to filter the 25 published topics by code, fault name or keyword; matching topics open automatically. Each diagnostic record can also be downloaded as a Word (.doc) file.
A series circuit fault rarely announces itself clearly — it shows up as one dim fixture, a CCR trip, or an intermittent open.
Build the technical knowledge to understand constant-current loop behavior, how a single open or short propagates through the whole circuit, and how to localize a fault instead of guessing at it.
Diagnose systematically. Understand the circuit. Build real AGL expertise.
Please read before relying on any content on this page or on any record downloaded from it.