Ethernet Switch
The central hub for IP-based communication in modern AGL systems. Industrial Ethernet switches provide reliable, high-speed data connectivity between the ALCMS server, PLCs, Remote I/O, fiber converters, and other network devices, ensuring deterministic communication and fault-tolerant network topologies across the airfield.
Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.
What Is It?
An Ethernet Switch is a network device that connects multiple devices on a local area network (LAN), forwarding data packets between them based on MAC addresses. In AGL applications, industrial-grade Ethernet switches are used to build the communication backbone that links the Airfield Lighting Control and Monitoring System (ALCMS) server, programmable logic controllers (PLCs), Remote I/O units, fiber converters, and other intelligent devices. Unlike standard commercial switches, industrial Ethernet switches are designed for harsh environments: they support extended temperature ranges (-40°C to +75°C), provide redundant power inputs, offer ruggedized enclosures, and implement advanced networking features such as redundant ring topologies (e.g., ERPS, RSTP), VLAN segmentation, quality of service (QoS), and cybersecurity features (port security, ACLs). These switches ensure reliable, deterministic, and secure communication critical for airfield lighting control.
Purpose & Function
The industrial Ethernet switch exists to give the ALCMS server, PLCs, and Remote I/O units a communication backbone that's actually reliable in the same environment the lighting equipment itself has to survive — extreme temperatures, electrical noise from high-voltage AGL circuits, and continuous operation with no acceptable downtime. A standard commercial-grade switch simply isn't built to survive those conditions without becoming a point of failure for the entire control network.
Features like redundant ring topologies and redundant power inputs exist specifically because a single point of network failure in an airfield lighting control system could mean losing visibility or control over multiple circuits at once. By designing resilience into the network layer itself, the switch ensures that a single cable break or power supply fault doesn't cascade into a broader control system outage.
Where Is It Used?
Ethernet switches are deployed in all areas of the AGL network infrastructure, including:
- ALCMS Control Room: Core switches connecting servers, workstations, and network management consoles to the airfield network.
- CCR Substations: Managed switches connecting PLCs, Remote I/O, and fiber converters to the main network backbone.
- Runway Edge Cabinets: Switches providing local connectivity for lighting control modules, sensor nodes, and cameras.
- Approach Lighting Control Shelters: Switches for sequencer modules, strobe controllers, and fiber media converters.
- RWSL (Runway Status Light) Systems: Dedicated switches for the RWSL processing units, field controllers, and sensors.
- Airfield Sensor Networks: Connecting weather stations, visibility sensors, wind measurement systems, and RVR equipment.
- Gate & Apron Control Systems: Switches for docking guidance, gate management, and apron surveillance.
- Security & Surveillance: Switches supporting IP cameras, access control, and perimeter monitoring systems.
Installation & Location
Switches are DIN-rail or rack-mounted inside the control room, substation, or field cabinet they serve, with industrial-rated (wide-temperature, vibration-resistant) units specified for outdoor runway-edge cabinets and approach lighting shelters, and standard rack-mount units for the air-conditioned ALCMS control room. Power is fed from the same DC supply as the other equipment in that cabinet, often with a redundant supply input on critical switches; uplink connections to the network backbone run on fibre between cabinets/shelters (for distance and electrical isolation) and on copper for short local runs within a single cabinet, with cable routing kept separate from lighting series-circuit power cable throughout.
How Does It Work?
The Ethernet switch operates at Layer 2 of the OSI model, forwarding data frames based on MAC address tables. Key functional aspects in AGL networks include:
- MAC Address Learning: The switch builds a table of MAC addresses associated with each port, learning which devices are on which segments to forward frames only to the necessary port (reducing unnecessary traffic).
- Store-and-Forward Switching: Receives the entire frame, checks for errors using CRC, and forwards it to the destination port, ensuring error-free transmission.
- Redundant Ring Topology: Supports protocols like RSTP (Rapid Spanning Tree Protocol) or ERPS (Ethernet Ring Protection Switching) to provide automatic failover in case of a cable break or switch failure, with recovery times as fast as 50 ms (ERPS).
- VLAN Segmentation: Virtual LANs allow logical separation of traffic (e.g., control data, video surveillance, management traffic) for improved security and performance.
- Quality of Service (QoS): Prioritizes critical AGL control traffic (e.g., PLC-to-CCR commands) over less time-sensitive data (e.g., video streams) to ensure deterministic communication.
- Network Management: Supports SNMP (Simple Network Management Protocol) for remote monitoring, diagnostics, and configuration, allowing administrators to view port status, traffic statistics, and alarms.
- Cybersecurity: Implements features like port security (MAC locking), Access Control Lists (ACLs), and DHCP snooping to protect the network from unauthorized access and cyber threats.
Industrial switches are typically powered by 24 VDC (airfield standard) or 48 VDC, with dual redundant power inputs for high availability. They are often DIN-rail mounted in control cabinets.
System Architecture & Control Logic
The Ethernet switch is the shared backbone that every IP-capable node in the AGL system connects through — PLCs, Remote I/O, Communication Gateways, the SCADA Interface, Touchscreen HMIs, weather stations, and surface movement radar all terminate on switch ports rather than wiring directly to the ALCMS server. It does not participate in control logic itself; it forwards frames at Layer 2 based on MAC address tables and, where configured, segments traffic into VLANs so lighting-control data, radar/A-SMGCS data, and general IT traffic stay logically separated on the same physical fibre or copper backbone. Airfield deployments typically run switches in a redundant ring or dual-homed topology with RSTP or similar, so that a single fibre cut or switch failure reroutes traffic within milliseconds rather than dropping the affected branch off the network entirely.
PLC / Remote I/O
Circuit control & status
Weather Station / SMR
Environmental & movement data
Gateway / SCADA / HMI
Protocol bridging & local control
Ethernet Switch (Redundant Ring)
Layer-2 forwarding, VLAN segmentation, sub-second failover
ALCMS Server
Single logical destination for all connected nodes
How the Switch Handles Traffic & Failover
Frame Arrives at Switch Port
Incoming Ethernet frame from a connected device or uplink
MAC Address Table Lookup
Learns source address, matches destination to the correct port
Store-and-Forward
Frame CRC-checked, forwarded only to the destination port
QoS Prioritization
PLC↔CCR control traffic prioritized over video/management data
RSTP / ERPS Reroute
Ring topology restores traffic in as fast as 50 ms
Physical Construction
The switch is housed in a rugged extruded-aluminium or steel enclosure with a wide operating-temperature rating, built for DIN-rail mounting inside a control cabinet or field enclosure rather than a server-room rack. Copper ports use shielded RJ-45 connectors with integrated magnetics, while SFP cages for fibre uplinks are soldered directly to the backplane and accessed through dedicated front-panel cutouts, keeping the fibre optics separate from the copper ports for EMI isolation. Internal electronics are conformally coated to resist dust, humidity, and airborne contaminants, and the dual redundant power inputs terminate at screw-clamp terminals rated for the nominal 24 VDC supply. Where deployed outside a conditioned cabinet, the switch is fitted into a sealed IP65 enclosure with cable glands for each cable entry, and a chassis earth stud is provided for bonding to the cabinet ground bus.
Technical Parameters
| Parameter | Typical Value |
|---|---|
| Port Configuration | 8, 16, or 24 ports (10/100/1000BASE-T copper) + SFP slots (for fiber uplinks) |
| Fiber Uplinks | SFP slots supporting 100BASE-FX, 1000BASE-SX/LX/ZX (multi-mode/single-mode) |
| Switching Capacity | Up to 56 Gbps (non-blocking) for managed switches |
| Forwarding Rate | Up to 41.7 Mpps (for 24-port Gigabit switch) |
| Redundancy Protocols | RSTP, MSTP, ERPS (ring), link aggregation (LACP) |
| Management | Web GUI, CLI (SSH/Telnet), SNMP v1/v2c/v3, RMON |
| Cybersecurity | Port security, MAC filtering, ACLs, IEEE 802.1X (RADIUS), DHCP snooping |
| QoS | IEEE 802.1p, DiffServ (DSCP), 8 priority queues |
| Power Supply | 24 VDC (nominal, 18‑32 VDC) with dual redundant inputs |
| Power Consumption | 10‑50 W self-consumption (port count dependent); PoE-enabled ports draw additional power per the connected load, separate from this figure |
| Operating Temperature | -40°C to +75°C (industrial grade) |
| Storage Temperature | -40°C to +85°C |
| Protection Class | IP30 (DIN-rail mount), IP40 (ruggedized), IP65 (field mount with enclosure) |
| Mounting | DIN rail (standard) or panel mount |
| Diagnostics | Port status LEDs, system log, SNMP traps, port mirroring |
| Certifications | CE, FCC, UL, IEC 61000‑6‑2 (EMC immunity), IEC 61850 (substation) |
Electrical Requirements
| Requirement | Typical Value |
|---|---|
| Circuit Position | Standalone powered networking device, field or control-room mounted |
| Power Supply | 24 VDC (nominal, 18‑32 VDC) with dual redundant inputs |
| Power Consumption | 10‑50 W self-consumption (port count dependent); PoE load is additional, sized to the connected devices |
| PoE Output | Up to the port-rated PoE budget for connected field devices |
| Isolation | Powered separately from the AGL series circuit |
| Fault Protection | Dual-input redundancy; per-port overcurrent protection on PoE ports |
Applicable Standards
IEEE 802.3
Ethernet standards (10BASE-T, 100BASE-TX, 1000BASE-T, 1000BASE-X)
IEEE 802.1D/1w/1s
Spanning Tree Protocol (STP/RSTP/MSTP) for redundancy
IEEE 802.1Q
VLAN tagging and traffic segmentation standard
FAA AC 150/5345‑56
Specification for AGL control and monitoring equipment
Installation Requirements
Environment-Rated Unit Selection
CivilSpecify an industrial-rated, wide-temperature, vibration-resistant switch for outdoor runway-edge cabinets and approach lighting shelters, and a standard rack-mount unit for the air-conditioned ALCMS control room.
DIN-Rail or Rack Mounting
MechanicalMount the switch inside the control room, substation, or field cabinet it serves, positioned for clear access to its port panel for cabling and maintenance.
DC Power Feed
ElectricalFeed power from the same DC supply as the other equipment in that cabinet, wiring a redundant supply input where the switch is specified with one.
Fibre & Copper Uplink Routing
ElectricalRun fibre uplinks between cabinets or shelters for distance and electrical isolation, and copper for short local runs within a single cabinet, keeping routing separate from lighting series-circuit power cable.
VLAN & Port Configuration
DocumentationConfigure port assignments, VLANs, and redundancy protocols per the network design before the switch is brought into service.
Pre-Commissioning Sign-off
DocumentationRecord mounting location, power feed, and uplink cabling as-built before commissioning testing begins.
Testing & Commissioning
Cable & Port Continuity Test
Pre-CommissioningVerify every port and cable run tests clean before the switch is placed into service.
Network Topology & Redundancy Test
CommissioningConfirm the ring/redundant topology (e.g. ERPS, RSTP) correctly reroutes traffic when a link is broken.
VLAN & QoS Configuration Verification
CommissioningConfirm VLAN segmentation and QoS priorities match the design before live traffic is carried.
Throughput & Latency Test
CommissioningConfirm the switch sustains the required traffic load without excessive latency or packet loss.
Power Supply Redundancy Test
CommissioningWhere dual power inputs are fitted, confirm the switch continues operating uninterrupted on a single source.
Security Configuration Verification
Pre-CommissioningConfirm port security and access control lists match the design before go-live.
Enclosure & Thermal Check
Pre-CommissioningConfirm the enclosure is correctly sealed and the switch operates within its rated temperature range.
Documentation & As-Built Sign-off
Final AcceptanceRecord configuration, VLAN mapping, and test results in the commissioning dossier for handover.
Inspection & Maintenance
Cable & Connector Inspection
AnnualCheck cabling and connectors for damage or degraded contacts that can cause intermittent link loss.
Traffic Health Check
Semi-annualReview switch logs and port statistics for signs of broadcast storms or abnormal traffic patterns.
Power Supply Check
AnnualVerify power input stability and inspect the supply unit for signs of stress or ageing.
Enclosure Thermal Check
Semi-annualConfirm ventilation or cooling is adequate and the enclosure isn't trapping heat around the switch.
Firmware & Configuration Audit
AnnualReview firmware version and configuration against baseline to catch unplanned drift.
Security Patch Review
AnnualCheck for and apply relevant security patches to address known vulnerabilities.
Common Field Issues
Cable Damage & Faulty Connections
Damaged Ethernet cables (RJ‑45 connectors, broken wires) are a common cause of intermittent connectivity. Use shielded, industrial-grade cables (CAT5e/CAT6) and inspect connectors regularly. Consider using M12 connectors in harsh outdoor environments.
Broadcast Storms
Network loops caused by misconfiguration (e.g., connecting two ports without STP) can lead to broadcast storms, crippling the network. Always enable STP/RSTP and use ring topologies with proper redundancy protocols.
Power Supply Failure
Switches rely on stable power. Use dual redundant power supplies (if supported) and connect to a UPS system to prevent switch reboots during power fluctuations.
Overheating in Enclosures
Switches generate heat; inadequate ventilation or high ambient temperatures can cause performance degradation or premature failure. Ensure cabinets have proper cooling (fans, vents) and keep ambient temperature within the rated range.
Firmware/Configuration Drift
Updates or changes to switch configurations without proper documentation can introduce errors. Use configuration backup and version control, and perform firmware updates in a planned maintenance window.
Cybersecurity Vulnerabilities
Exposed management interfaces (e.g., default passwords, unsecured protocols) can be exploited. Implement strong passwords, disable unused services, and use SNMPv3 with encryption.
Troubleshooting Guide
Intermittent Connectivity on One Port
Network-Wide Slowdown or Total Loss of Connectivity
Switch Reboots Unexpectedly
Performance Degrades or Switch Fails During Warm Weather
Switch Behaving Differently Than Documented Configuration
Unauthorised Access or Configuration Change Detected
Failure Modes & Root Causes
Cable / Port Degradation
Network Loop / Broadcast Storm
Power Supply Failure
Thermal Overload
Undocumented Configuration Drift
Unauthorised Access
Safety & Operational Notes
Isolate Both Redundant Power Inputs
Electrical SafetyWhere the switch is fed by dual redundant 24VDC inputs, isolate and verify zero energy on both before internal work, since disconnecting only one leaves the unit powered from the other.
PoE Port Voltage
Electrical SafetyIf any ports supply Power over Ethernet to connected devices, treat those ports as carrying hazardous voltage (up to around 55-57V) even when the switch's main supply appears isolated at a glance; disconnect or confirm PoE is disabled before handling those cables.
Fiber Port Laser Safety
Personnel SafetyNever look directly into an active fiber port or the end of a connected fiber patch lead on SFP-equipped switches; although typically low-power (Class 1) and normally eye-safe, use an optical power meter rather than direct viewing to check for a live signal.
ESD-Sensitive Electronics
OperationalUse anti-static precautions when handling internal boards or SFP modules.
Coordinate Before Taking Down the Comms Backbone
OperationalThe switch may carry traffic for the ALCMS server, PLCs, and Remote I/O across the airfield; confirm what monitoring or control capability is lost before isolating it, and coordinate with control-room operators accordingly.
Restore to Compliant State
ComplianceConfirm all connected devices re-establish communication and link status is correct on every active port before closing out the work.
Engineering & Expert Notes
An Uncommissioned Redundancy Protocol is a Loop Waiting to Happen
Network DesignA ring topology wired correctly but with RSTP/ERPS left at default or misconfigured settings doesn't fail safely — it can create a genuine broadcast storm the moment a second physical path is connected. Verify the actual ring protocol convergence behaviour by testing a real link break during commissioning, not just confirming the protocol is "enabled" in the configuration.
Cabinet Heat Load Compounds Over Years, Not Just Summers
ThermalA switch that runs within its rated temperature range in its first year can start showing intermittent faults years later as cabinet ventilation degrades — dust-clogged fans, aging seals letting in less airflow than designed, or added equipment sharing the same enclosure. Re-verify actual cabinet internal temperature periodically rather than assuming the original thermal design still holds.
VLAN Misconfiguration Often Hides Behind "It Works Most of the Time"
TroubleshootingA VLAN tagging mismatch between two switches in a ring can allow normal traffic through while silently dropping specific VLANs during a failover reroute, so the fault only appears under the exact condition the redundancy protocol was meant to handle. Test VLAN behaviour specifically during a simulated link failure, not only under normal operation.
Verify Both Power Inputs Are Actually Independent
ElectricalDual power inputs only deliver real redundancy if they're fed from genuinely separate sources; wiring both inputs from the same distribution panel or the same UPS output defeats the purpose while still passing a basic connectivity test. Trace both feeds back to their actual origin during commissioning, not just confirm the switch accepts two cables.
Configuration Drift Accumulates Quietly Across Field Visits
ConfigurationAd hoc port or VLAN changes made during troubleshooting visits, without updating the master configuration backup, gradually pull the live switch config away from what's documented. Pull and diff a configuration backup at every scheduled maintenance visit, not only after planned changes, to catch this kind of unrecorded drift.
SNMP is Often the Overlooked Attack Surface
CybersecurityTeams commonly harden the switch's web/CLI management access while leaving SNMPv1/v2c community strings at default, forgetting that SNMP itself can expose or even allow modification of switch configuration. Audit SNMP settings with the same rigor as login credentials, and prefer SNMPv3 with authentication and encryption wherever the equipment supports it.
Frequently Asked Questions
Short answers about industrial Ethernet switches in AGL networks: redundancy, VLANs, specifications, standards and maintenance.
Q1What is an industrial Ethernet switch in an AGL system?
It is a network device that connects multiple devices on a LAN and forwards data frames by MAC address. In AGL applications, industrial-grade switches build the communication backbone linking the ALCMS server, PLCs and remote I/O units.
Q2Why use industrial-grade switches instead of office switches?
The backbone has to be reliable in the same environment the lighting equipment survives: extreme temperatures and electrical noise. Industrial switches are rated for -40°C to +75°C and have dual redundant power inputs.
Q3Where are Ethernet switches deployed?
Across the AGL network: core switches in the ALCMS control room connecting servers, workstations and management consoles, and managed switches at CCR substations connecting local controllers to the backbone.
Q4How does an Ethernet switch work?
It operates at Layer 2, learning which MAC address sits on which port and forwarding each frame only to the right port instead of flooding the network.
Q5What are the typical specifications?
8, 16 or 24 copper ports (10/100/1000BASE-T) plus SFP slots for fibre uplinks (100BASE-FX, 1000BASE-SX/LX/ZX), switching capacity up to 56 Gbps non-blocking, and 8 QoS priority queues using IEEE 802.1p and DiffServ.
Q6What redundancy and security features are typical?
Redundancy protocols include RSTP, MSTP, ERPS (ring) and LACP link aggregation. Security features include port security, MAC filtering, ACLs, IEEE 802.1X (RADIUS) and DHCP snooping, with management via web GUI, SSH, SNMP v1/v2c/v3 and RMON.
Q7How is an industrial Ethernet switch powered?
Typically from 24 VDC (18-32 VDC) with dual redundant inputs, separate from the AGL series circuit. Self-consumption is 10-50 W depending on port count, and PoE ports draw additional power for connected devices.
Q8Which standards apply?
IEEE 802.3 (Ethernet), IEEE 802.1D/1w/1s (STP/RSTP/MSTP), IEEE 802.1Q (VLAN tagging and segmentation) and FAA AC 150/5345-56 for AGL control and monitoring equipment.
Q9How often should an Ethernet switch be maintained?
Semi-annually for traffic health (logs and port statistics for broadcast storms) and enclosure thermal checks, and annually for cable and connector inspection, power supply checks, firmware and configuration audits against baseline, and security patch review.
Q10Why does one port show intermittent connectivity?
Likely a damaged Ethernet cable, worn RJ-45 connector or broken conductor on that run, especially outdoors without M12-rated connectors. Swap the suspect cable and re-test.
Related Components
Go Beyond the Component. Understand the Complete AGL System.
You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.
Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.
Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.
Your next step in AGL starts here.
Need expert guidance on Ethernet switch selection, network design, or cybersecurity for your AGL system?
Precision AGL Academy provides advice on switch specifications, ring topologies, VLAN design, and best practices for secure industrial networks.
Follow the Academy
Important Notice, Disclaimer & Limitation of Liability
Please read before relying on any content on this page.
- Purpose and intended users. This page on Ethernet Switch is an independent educational and informational reference for competent, suitably trained and authorised airfield ground lighting (AGL) and aerodrome electrical personnel. It is not professional engineering, legal or regulatory advice, and using it does not create any professional or client relationship.
- Safety. Work on series circuits, constant current regulators (CCRs), isolating transformers, cables, connectors and lighting equipment can be fatal. Always apply the aerodrome’s permit-to-work and isolation/LOTO procedures, prove dead, use correctly rated instruments and PPE, and follow the manufacturer’s instructions. Nothing here authorises work on live equipment or the bypassing of any safety device or interlock.
- Aviation operations. Nothing here authorises installation, modification, energisation, adjustment, return to service, a change of operating category (CAT I/II/III), a NOTAM or any aerodrome certification or approval decision. These rest with the aerodrome operator, the air navigation service provider and the competent regulator.
- Specifications, ratings and typical values. Descriptions, parameters, ratings, dimensions, photometric values, wattages, service lives, maintenance tasks and intervals, failure modes, certifications (for example CE, FCC, UL or IEC marks) and part or type designations are general, typical and indicative. They may not match any particular product, make, model or version, and they are not a datasheet, design, specification, selection, sizing, procurement or acceptance criterion. The manufacturer’s current documents, the approved design and the project specification prevail.
- Standards and regulations. References to ICAO, FAA, IEC, IEEE, ISO, BIS, DGCA and other standards are paraphrased summaries for orientation only. They may be incomplete or out of date, and standards are revised from time to time. Consult the current official editions. Following this content does not guarantee compliance with any law, standard or regulatory approval, and the regulator’s requirements always prevail.
- No warranty. Content is provided “as is” and “as available”, without warranty of any kind, express or implied, including accuracy, completeness, currency or fitness for a particular purpose. Real installations differ in design, equipment make and model, age and condition.
- Limitation of liability. To the fullest extent permitted by applicable law, Precision AGL Academy, Precision AGL Solutions and their owners, authors and contributors are not liable for any injury, death, loss, damage, downtime, penalty or regulatory consequence, whether direct or indirect, arising from the use of, reliance on, or inability to use this content. Nothing in this notice excludes or limits any liability that cannot lawfully be excluded or limited.
- Independence, brands and no endorsement. This is an independent publication. It is not affiliated with, sponsored by or endorsed by ICAO, the FAA, the IEC, DGCA, AAI, any airport, regulator, supplier or equipment manufacturer. Third-party names, product designations, standard designations and trademarks (including Megger®, Siemens, Eaton, Crouse-Hinds, ADB SAFEGATE, Fluke, ABB and Honeywell) belong to their respective owners and are used only for identification and description. Mention of a brand, product or supplier is not a recommendation, and we do not sell, supply or quote for any component described.
- Images and third-party content. Images and illustrations are shown to help identify the type of component. They may show products of various manufacturers, may not depict the exact item described, and are not a statement about any product’s quality, approval or performance. Copyright and trademarks in third-party images, logos and photographs belong to their respective owners and are not claimed as ours. If you are a rights holder and want an image removed, replaced or credited, email precisionaglsolutions@gmail.com with the page address and we will act promptly.
- Training and services. Mentions of training, courses, consultation, advice, selection, installation, calibration or other support, including the “Learn…Certify” pathway, describe learning stages and are not an offer, quotation, tender or promise of any result. Contacting us or our replying creates no engagement or duty of care; an engagement exists only under a written agreement. We are not a regulator or certification body, and completing any course or reading this content is not a certification, accreditation or authorisation to work on any aerodrome.
- Copyright, privacy and corrections. © 2026 Precision AGL Academy. All rights reserved. Text, structure, compilations and diagrams may be viewed for personal reference and internal training only; any other copying, republication or commercial use needs our written permission. If you email, telephone or message us, we use your details only to respond and handle your matter, in line with applicable Indian law including the Digital Personal Data Protection Act, 2023; please do not send confidential or security-sensitive information. To display this page your browser requests fonts, icons and images from third-party servers, which receive your IP address and browser details under their own policies. Content is reviewed periodically with no obligation to update. To report an error, safety concern or rights issue, write to precisionaglsolutions@gmail.com.