Approach Lighting

Sequenced Flashing Light System for Airfield Ground Lighting

A dynamic visual cue toward the runway threshold

Approach AreaWhite Sequenced FlashersICAO Annex 14 / FAA AC 150/5340-30J

Sequenced Flashing Light Systems provide a dynamic visual indication along the extended runway centreline. Individual flashing units operate in a controlled sequence, creating the impression of light moving toward the runway threshold.

Supplied by Precision AGL Solutions

Sequenced Flashing Light System

What It Is

Instead of a continuous steady-burning pattern, the system flashes individual units in sequence. This helps pilots identify the approach-lighting system at greater range and supports approach-path identification, runway alignment, the transition from instrument to visual flight, early recognition of the approach axis and improved conspicuity against high background lighting.

FAA describes the effect as a ball of light travelling toward the runway.

Selected According To

  • Approach lighting system
  • Runway classification and approach category
  • System length
  • Number of flasher stations and spacing
  • Flash sequence, rate and synchronization
  • Light intensity, optical direction and beam distribution
  • Control architecture, power supply and monitoring
  • Mounting arrangement and environmental conditions
  • Project technical specification

The final system should always be selected according to the approved approach-lighting design and applicable aviation standard.

Where Sequenced Flashing Lights Are Used

FAA identifies ALSF-1, ALSF-2, SSALF, MALSF and other approach-lighting configurations incorporating sequenced flashing lights.

Precision approach systemsIncluding Category I, II and III approach systems.
MALS / MALSF / MALSRMedium-intensity approach lighting configurations.
SALSF / SSALFShort and simplified short approach lighting systems with sequenced flashers.
ALSF-1 / ALSF-2High-intensity approach lighting systems.
RAIL configurationsRunway Alignment Indicator Light arrangements.
High-background-light environmentsWhere the approach is hard to identify.
Upgrades & rehabilitationApproach-lighting upgrades and airport rehabilitation projects.
New installationsNew approach-lighting installations.

An Early, Conspicuous Dynamic Reference

Why the Motion Matters

The principal purpose is an early and conspicuous dynamic reference toward the runway. A steady-burning light creates a static pattern; the sequence adds a moving cue that helps the pilot identify the correct system and runway alignment.

FAA states that MALSR sequenced flashers appear as a ball of light travelling toward the runway.

Sequence Progression

Outer flasher
Next flasher
Next flasher
Nearer runway
Threshold

Two Components, Two Visual Functions

A complete approach-lighting system may contain both.

Steady-Burning Approach Lights

  • Continuous longitudinal reference
  • Horizontal reference
  • Approach geometry
  • Runway alignment

Sequenced Flashing Lights

  • Dynamic identification
  • Long-range conspicuity
  • Directional movement cue
  • Additional lead-in information

Sequential Flashing Along the Extended Centreline

Simplified Concept

════ RUNWAY ════
      THRESHOLD
          │
    ●  FLASH 5   (innermost)
    ●  FLASH 4
    ●  FLASH 3
    ●  FLASH 2
    ●  FLASH 1   (outermost)
        APPROACH

Notes

Flashes occur sequentially from the outer approach area toward the runway. The exact number of flashers and their spacing depend on the selected approach-lighting system.

Outermost → Innermost → Threshold

One of the Most Important Characteristics

For the principal runway approach systems the sequence progresses outermost → innermost → threshold, creating apparent motion toward the runway.

Standards Basis

ICAO precision approach provisions specify sequential flashing beginning with the outermost light and progressing toward the threshold. FAA approach systems similarly operate the flashers from the outer approach area toward the threshold.

Timing Defines the Visual Effect

The product should not be specified using an assumed generic flash rate.

Controlled Accurately

FAA guidance for systems such as MALSF identifies sequenced flashers operating at approximately twice per second, meaning the whole sequence repeats about 120 times per minute, with each flasher firing once per cycle. FAA AC 150/5345-51B sets different rates for unidirectional and omnidirectional flashers (for example, runway end identifier lights), so take the rate for your flasher type from the current edition of that document and the approved system drawing.

Take the Exact Characteristic From

  • Applicable system standard
  • Current FAA / ICAO requirement
  • Approved project drawing
  • Manufacturer specification

System Dependent

The number of flashers is not universal; it depends on the approach-lighting system, as the examples below show.

SystemFAA Description
MALSFMALS with three sequenced flashers at the outer three light-bar stations
MALSRTypically five sequenced flashing lamps (up to eight) along the extended runway centreline beyond the steady-burning light field
ALSF-2Typical 2,400 ft system with 15 sequenced flashers (up to 21 on a 3,000 ft system) operating from the outermost station toward the runway
Correct number = Approach System + System Length + Approved Layout

Taken from the Approved System Drawing

System-Specific Stationing

For example, FAA MALSR flashers (typically five, up to eight) are spaced at 200 ft intervals, beginning 1,600 ft from the threshold. ALSF configurations use different arrangements and stationing according to the applicable system.

Final Spacing

The final spacing must be taken from the approved system drawing.

White Approach-Light Field

Normally White

The flashing element is normally associated with the white approach-light field. FAA identifies the flashers in systems such as MALSR and ALSF-2 as white flashing lights.

Colour Verification

  • Chromaticity
  • White output
  • Consistency between flashers
  • Intensity
  • Optical distribution

The flasher colour must remain visually consistent with the approach-lighting system.

Designed Around the Approaching Aircraft

The Optical System Should Provide

  • Appropriate horizontal coverage
  • Appropriate vertical coverage
  • Correct main beam direction
  • Consistent output between stations
  • Visibility from the intended approach sector
  • Controlled glare / spill

FAA MALSF guidance aims the steady and flashing lights with beam axes parallel to the runway centreline and intersecting the assumed approach glide-slope geometry.

Photometric Review Considers

  • Horizontal and vertical beam spread
  • Main beam axis
  • Approach angle
  • Aircraft height and viewing distance
  • Background lighting
  • Threshold relationship

Each flasher must be clearly visible from the intended approach area and the sequential effect must remain continuous.

Sufficient Range, Coordinated Control

Intensity Selection Depends On

  • Approach-lighting system and approach category
  • Ambient background lighting and visibility
  • Optical design and flasher type
  • Control configuration

FAA material notes effective intensity can require adjustment in high-background-light environments. Coordinate settings with the steady-burning elements.

Control Characteristics

The flashing subsystem may differ from the steady lights. FAA inspection guidance states the three MALSF flashers do not have their own intensity control and follow the steady-burning lights' settings.

Establish flasher intensity, available steps, relationship to steady-burning lighting, CCR / control architecture and independent or shared intensity control.

The Critical Part of the System

Approach Lighting Control
Sequencer / Timing Controller
Flasher Channels
Flasher Units

The Controller Must Maintain

  • Correct order and timing
  • Correct synchronization
  • Correct intensity
  • Reliable triggering
  • Fault monitoring

A timing fault can make the system appear static, irregular or out of sequence.

Synchronization

  • Correct sequence order
  • Consistent interval and repeatable cycle
  • Stable timing
  • No unintended simultaneous operation
  • Correct restart after power interruption

Verify synchronization during commissioning where several independent flasher modules are used.

Dedicated Circuit and Control Arrangement

These systems can use a dedicated electrical / control architecture rather than simply placing flashers in parallel with steady-burning lights.

May Include

  • Dedicated flasher circuit
  • CCR supply or dedicated power supply
  • Sequencer
  • Individual flasher channels
  • Control cabinet
  • Monitoring circuit
  • ALCMS interface

Simplified Concept

CCR / Power Supply
Flasher Circuit
Sequencer
Flashers 1 to n

Operate Independently of Other Approach Lights

ICAO Provision

For certain precision approach systems, ICAO requires the electrical circuit to be arranged so the flashing lights can be operated independently of other approach-lighting lights.

The Technical Submission Should State

  • Flasher and steady-light circuit arrangement
  • Control relationship and CCR allocation
  • Fault isolation
  • Maintenance isolation

This can simplify testing and fault diagnosis.

Local and Remote Control

The final interface depends on the project control philosophy.

May Interface With

  • AGL control panel
  • Approach-lighting control cabinet
  • ALCMS and CCR
  • Sequencer / controller
  • Local maintenance panel
  • Remote monitoring
  • Airport operations system

Potential Functions

  • ON / OFF and intensity selection
  • Sequence activation
  • Status monitoring and fault indication
  • Remote control
  • Maintenance mode
  • Alarm reporting

Fast, Repeatable Switching

Potential Advantages

  • Fast switching
  • Long service life
  • Stable optical output
  • Reduced maintenance
  • Consistent colour
  • Lower energy consumption
  • Precise electronic timing
  • Diagnostic capability

The complete flasher must satisfy optical, timing, intensity, electrical, mechanical and environmental performance.

Switching Parameters

  • Rise / fall time
  • Pulse duration
  • Flash intensity
  • Timing accuracy
  • Repetition rate
  • Thermal management
  • Driver performance
  • EMC performance
  • Surge protection

Obtain values from the manufacturer's technical documentation.

Supports, Geometry and Frangibility

Installation Forms

  • Elevated fixtures
  • Light-bar assemblies
  • Low-level approach fixtures
  • Dedicated flasher heads
  • Frangible-mounted equipment
  • Modular LED units

Coordinate supports with approach geometry, frangibility, height, beam axis, wind loading, ground conditions, cable routing and maintenance access.

Approach Area Geometry

  • Runway extended centreline
  • Approach-lighting stationing
  • Glide-slope reference
  • Light-support elevation
  • Obstruction environment
  • Cable routes and drainage

FAA MALSF layout guidance specifies the optimum approach-light plane, slope tolerances and beam-aiming requirements.

Approach-Area Structures

May Include

  • Frangible supports
  • Low-impact structures
  • Breakaway mounting
  • Controlled fixture elevation

FAA Projects

Select support structures according to the applicable FAA low-impact / frangibility requirements for approach lighting.

Where Sequenced Flashers Add Most Value

Potential Sources

  • City lighting
  • Roads and buildings
  • Industrial facilities
  • Airport apron lighting
  • Stadiums
  • Commercial development

Evaluation

Evaluate the system for sufficient conspicuity under the actual operational environment.

Because the Effect Relies on the Sequence

The Control System Should Consider

  • Flasher and controller failure
  • Power failure
  • Timing and communication failure
  • Channel failure
  • Loss of synchronization

Operational Effect

The effect of individual failures depends on the governing standard and approach category. FAA material notes that the effect of inoperative SFL / RAIL equipment on approach serviceability depends on approach category and system configuration.

Functional and Timing Verification

Not merely lamp illumination testing.

Visual Inspection

  • Flasher and lens condition
  • Mounting and alignment
  • Station location
  • Cable condition
  • Control equipment
  • Support condition and frangibility

Electrical Testing

  • Circuit continuity
  • Insulation resistance
  • Power supply and CCR operation
  • Cable integrity
  • Controller power
  • Flasher input and monitoring

Sequence Testing

  • Correct first and last flasher
  • Correct sequence direction
  • Correct timing and repeat cycle
  • No skipped station
  • No simultaneous unintended flash
  • Stable synchronization

Flash-Rate Testing

  • Flash rate
  • Inter-flasher timing
  • Pulse duration
  • Repeatability

Photometric Testing

  • White colour
  • Intensity
  • Beam distribution and optical direction
  • Uniformity and visibility

Inspect the Complete Subsystem

Optical

  • Lens cleanliness and damage
  • Light output
  • Colour
  • Beam direction

Mechanical

  • Flasher head and housing
  • Mounting and support
  • Fasteners
  • Frangibility
  • Corrosion

Electrical

  • Controller
  • Cable and connector
  • Power supply and CCR
  • Circuit insulation

Timing

  • Sequence and flash rate
  • Synchronization
  • Missing flashes
  • Delayed channels

Control

  • ON / OFF and intensity
  • Remote status
  • Fault indication
  • Alarm reporting

Symptoms and Possible Causes

SymptomPossible Causes
All flashers OFFPower-supply failure; CCR failure; controller failure; circuit interruption; ALCMS/control command; main fuse/protection failure
One flasher OFFLED/light-source failure; channel failure; cable fault; connector problem; individual driver failure
Wrong sequenceController configuration error; wiring error; channel assignment problem; sequencer fault
Incorrect flash rateTiming-controller failure; oscillator/reference failure; controller configuration; communication problem
Simultaneous flashingSequencer failure; synchronization failure; incorrect wiring; controller fault
Weak / low-intensity flashOptical contamination; LED degradation; driver problem; incorrect intensity setting; electrical supply issue
Uneven visual sequenceMixed fixture output; individual flasher degradation; incorrect alignment; timing inconsistency; different optical configurations

Use a Systematic Diagnostic Sequence

Approach Control
Command / Intensity Setting
Power Supply / CCR
Sequencer
Timing Reference
Flasher Channel
Flasher Driver
Light Source
Optical Alignment
Photometric Verification
For a sequence problem, also check: Channel numbering → Wiring → Station order → Timing → Synchronization

Key Selection Parameters

Selection ParameterRequirement
ApplicationApproach lighting
SystemMALSF / MALSR / SSALR / SALSF / SSALF / ALSF / project-specific
Approach categoryProject specific
Number of flashersSystem dependent
Flasher spacingSystem / layout dependent
SequenceOuter → threshold
Flash rateStandard / system specific
Light colourWhite / system specific
OperationSequenced
IntensityStandard / system specific
BeamApproach geometry specific
Optical directionToward runway
SequencerRequired
SynchronizationRequired
ControlLocal / centralized
MonitoringProject specific
CircuitDedicated / shared according to system
CCRProject specific
PowerSystem specific
SupportElevated / frangible / system-specific
EnvironmentAirport specific
DocumentationTDS / photometry / timing / certificates

Before Ordering, Confirm

  1. Airport / project
  2. Runway designation
  3. Approach category
  4. Approach-lighting system
  5. MALSF / MALSR / SSALR / SALSF / SSALF / ALSF configuration
  6. Number of flashers
  7. Flasher stations
  8. Flasher spacing
  9. Sequence direction
  10. Flash rate
  11. Synchronization
  12. Pulse / timing characteristic
  13. Light colour
  14. Intensity
  15. Intensity control
  16. Beam distribution
  17. Optical axis
  18. Centreline alignment
  19. Sequencer / controller
  20. Power supply
  21. CCR compatibility
  22. Dedicated circuit requirement
  23. Control interface
  24. Monitoring
  25. ALCMS integration
  26. Support structure
  27. Frangibility
  28. Cable arrangement
  29. Environmental requirements
  30. Applicable standard
  31. Manufacturer TDS
  32. Photometric documentation
  33. Timing / sequencing documentation
  34. Type-test / compliance documentation
  35. Project approval requirements

Technical Documents to Request

For technical approval and procurement, request the applicable manufacturer documentation.

  1. Product datasheet
  2. Technical specification
  3. Photometric report
  4. Beam distribution diagram
  5. Colour / chromaticity information
  6. Flasher station layout
  7. Number of flasher units
  8. Station spacing
  9. Flash sequence diagram
  10. Flash-rate specification
  11. Timing / synchronization specification
  12. Pulse-duration information
  13. Intensity information
  14. Electrical specification
  15. Operating current
  16. Power consumption
  17. CCR compatibility
  18. Controller / sequencer specification
  19. Control wiring diagram
  20. Monitoring interface
  21. Fault-detection details
  22. Mounting drawing
  23. Support-structure details
  24. Frangibility information
  25. Cable-routing requirements
  26. Installation dimensions
  27. Environmental rating
  28. Installation manual
  29. Maintenance manual
  30. Compliance certificates
  31. Type-test reports
  32. Warranty information

Governing Standards

Select, install, control and test as part of the complete approved approach-lighting system.

ICAO

Annex 14 approach-lighting provisions address sequenced flashing elements within configured systems. For applicable precision approach systems, flashers operate in sequence from the outermost light toward the threshold, with the electrical design allowing independent operation. The approach category and configuration determine whether flashers are required. Verify the current publication, amendments and corrigenda before procurement.

FAA

FAA AC 150/5340-30J — Design and Installation Details for Airport Visual Aids is listed as active and covers approach lighting, including MALSF layouts and sequenced flashers.

  • MALSF: three sequenced flashers at the outer three light-bar stations
  • MALSR: typically five sequenced flashers (up to eight) along the extended centreline
  • ALSF-2: typically 15 sequenced flashers on a 2,400 ft system, up to 21 on a 3,000 ft system, operating from the outer approach area toward the threshold
  • FAA Order JO 6850.2 — Visual Guidance Lighting Systems, which defines the MALSR, ALSF-1/ALSF-2 and SSALR configurations and flasher stationing

FAA AC 150/5345-51B covers discharge-type flashing light equipment (the flasher equipment used in sequenced flashing light and RAIL arrangements); verify the current edition. Where LED flashers are offered, confirm with the airport authority how their performance is qualified against the project specification. MALSF and MALSR are not the same system. Establish the project system designation before selecting flasher equipment.

India

  • DGCA requirements
  • Airport-specific AGL specification
  • Approved approach-lighting layout
  • Approach category and system type
  • Flasher quantity and flash sequence
  • RVR / visibility requirements
  • CCR / control arrangement and ALCMS integration
  • Project BOQ and Employer's requirements
  • Applicable Indian Standards
  • Airport operator requirements

Always verify the applicable document edition and project-specific requirements before technical approval, procurement or installation.

Sequenced Flasher vs Approach Centreline vs Crossbar

FeatureSequenced FlasherApproach Centreline
Primary functionDynamic approach identificationContinuous alignment
OperationFlashing sequenceSteady-burning / system specific
Visual effectApparent movement toward runwayStatic reference
Typical colourWhiteWhite
ControlSequencer requiredStandard intensity / control
TimingCriticalNot applicable
InstallationApproach areaApproach centreline
System roleDynamic lead-in cueLongitudinal reference
FeatureSequenced FlasherCrossbar
Main functionDynamic approach identificationTransverse reference
OperationSequential flashingNormally steady
PatternMoving visual effectStatic transverse bar
Main parameterTiming / sequenceLength / station / spacing
System roleConspicuityGeometry

Closely Related, Not Universally Identical

Do Not Treat as Identical

RAIL and sequenced flashing lights are closely related in some FAA approach systems but should not be treated as universally identical products.

The FAA System Designation Determines

  • Number of units
  • Location and sequence
  • Operational effect
  • Approach-category implications

FAA inspection guidance distinguishes SFL and RAIL and describes different consequences for inoperative units by approach category.

Sequenced Flashing Light System — Frequently Asked Questions

What is a sequenced flashing light system?

It is a dynamic visual indication along the extended runway centreline. Individual flashing units operate in a controlled sequence, creating the impression of light moving toward the runway threshold, which the FAA describes as a ball of light travelling toward the runway. It helps pilots identify the approach-lighting system at greater range and supports approach-path identification, runway alignment and early recognition of the approach axis.

Which approach lighting systems use sequenced flashers?

FAA identifies ALSF-1, ALSF-2, SSALF, MALSF and other configurations that incorporate sequenced flashing lights. They are used in precision approach systems including Category I, II and III, in MALS, MALSF and MALSR medium-intensity systems, in SALSF and SSALF short systems, in RAIL configurations, in high-background-light environments, and in upgrade and new installations.

In which direction does the sequence run?

For the principal runway approach systems the sequence progresses from the outermost flasher to the innermost and then the threshold, creating apparent motion toward the runway. ICAO precision approach provisions specify sequential flashing beginning with the outermost light and progressing toward the threshold, and FAA approach systems similarly operate the flashers from the outer approach area toward the threshold.

How many flashers does a system have?

The number is not universal and depends on the approach-lighting system, its length and the approved layout. The FAA describes MALSF as having three sequenced flashers at the outer three light-bar stations, MALSR as typically five sequenced flashing lamps (up to eight) along the extended centreline, and ALSF-2 as typically 15 sequenced flashers on a 2,400 ft system, up to 21 on a 3,000 ft system. The final spacing must be taken from the approved system drawing.

What is the flash rate?

The product should not be specified using an assumed generic flash rate. FAA guidance for systems such as MALSF identifies sequenced flashers operating at approximately twice per second, so the whole sequence repeats about 120 times per minute, with each flasher firing once per cycle. FAA AC 150/5345-51B sets different rates for unidirectional and omnidirectional flashers, so take the rate for your flasher type from the current edition of that document and the approved system drawing.

What colour are sequenced flashers?

They are normally white, associated with the white approach-light field, and the FAA identifies the flashers in systems such as MALSR and ALSF-2 as white flashing lights. Colour verification covers chromaticity, white output, consistency between flashers, intensity and optical distribution.

What does the sequencer or controller do?

The sequencer or timing controller is the critical part of the system. It must maintain the correct order and timing, synchronization, intensity, reliable triggering and fault monitoring. A timing fault can make the system appear static, irregular or out of sequence. It should also give a correct restart after a power interruption, and synchronization should be verified during commissioning where several independent flasher modules are used.

Do the flashers need their own circuit?

They can use a dedicated electrical and control architecture, which may include a dedicated flasher circuit, a CCR or dedicated power supply, the sequencer, individual flasher channels, a control cabinet, a monitoring circuit and an ALCMS interface. For certain precision approach systems, ICAO requires the circuit to be arranged so the flashing lights can be operated independently of the other approach lights. The technical submission should state the circuit arrangement, control relationship and CCR allocation, fault isolation and maintenance isolation.

How is flasher intensity controlled?

Intensity depends on the approach-lighting system and category, ambient background lighting and visibility, the optical design and flasher type, and the control configuration. FAA material notes the effective intensity can need adjustment in high-background-light environments, and FAA inspection guidance states the three MALSF flashers have no intensity control of their own and follow the steady-burning lights’ settings. Coordinate the settings with the steady-burning elements.

How are sequenced flashers mounted?

Installation forms include elevated fixtures, light-bar assemblies, low-level approach fixtures, dedicated flasher heads, frangible-mounted equipment and modular LED units. Supports should be coordinated with the approach geometry, frangibility, height, beam axis, wind loading, ground conditions, cable routing and maintenance access. For FAA projects, select support structures according to the applicable FAA low-impact and frangibility requirements for approach lighting.

How are sequenced flashers tested and what are the common faults?

Testing is functional and timing verification, not merely lamp illumination. It covers visual inspection, electrical tests, sequence testing (correct first and last flasher, direction, repeat cycle, no skipped station, no unintended simultaneous flash), flash-rate testing and photometric testing. Typical faults include all flashers off (power supply, CCR, controller or circuit), one flasher off (light source, channel, cable or connector), wrong sequence (configuration, wiring or sequencer), incorrect flash rate (timing controller or reference), simultaneous flashing (sequencer or synchronization failure) and weak flashes (contamination, LED degradation or intensity setting).

Which standards apply to sequenced flashing light systems?

References include ICAO Annex 14 approach-lighting provisions, FAA AC 150/5340-30J, FAA Order JO 6850.2 on visual guidance lighting systems and FAA AC 150/5345-51B on discharge-type flashing light equipment. Where LED flashers are offered, confirm with the airport authority how their performance is qualified against the project specification. MALSF and MALSR are not the same system, so establish the project system designation before selecting flasher equipment. For India, also verify DGCA requirements, the airport-specific AGL specification and the approved approach-lighting layout, and confirm the applicable edition of each document.

A Controlled Subsystem of the Approach System

We treat the Sequenced Flashing Light System as a controlled subsystem of the complete approach-lighting system. Our approach considers:

Approach Category → System Type → Flasher Quantity → Stationing → Sequence → Timing → Intensity → Optics → Support → Power → Sequencer → Control → Monitoring → Photometry → Maintenance

This helps ensure the flashing system remains synchronized with the steady-burning approach-light field.

Procurement Information for Indian Projects

Indian public tenders commonly ask for the documents below. State which ones your tender requires when you send the enquiry, so they are covered in the quotation.

  • Manufacturer / OEM authorisation
  • Country of origin and local-content declaration (for Make in India purchase preference)
  • Type-test and routine-test certificates, and the FAA / ICAO / IEC compliance documents named in the specification
  • Datasheets, drawings and installation instructions
  • Warranty, delivery period and spares support
  • GeM catalogue or tender-portal requirements, where applicable

Request Complete Approach System Configuration

Planning a new approach lighting system, precision runway upgrade, MALSF / MALSR / ALSF project or approach-lighting rehabilitation? Submit your runway designation, approach category, existing system, approved layout, system length, flasher locations and quantity, centreline / crossbar / side-row arrangement, RVR requirement, required intensity, existing CCR / control arrangement, ALCMS interface, BOQ, technical specification and existing flasher TDS where available. Precision AGL Solutions can review the complete configuration and support selection of the sequenced flashing units, controller, timing arrangement, power interface and technical documentation.

Submitting opens your email client with the enquiry pre-filled. You can also email us directly at the address shown.

Engineering Note

A sequenced flashing light system should not be specified merely as “flashing approach lights.” The important parameters are system type, flasher quantity, station spacing, sequence direction, flash rate, synchronization, effective intensity, beam alignment, controller architecture and interaction with steady-burning approach lights.

FAA configurations differ materially: MALSF uses three sequenced flashers, MALSR typically uses five, and a typical ALSF-2 uses 15 (up to 21 on a 3,000 ft system). The approach-lighting system designation must be confirmed before the flasher product is selected, and the equipment checked against the current standard, approved airport drawing and manufacturer documentation.

Product Disclaimer

Product availability, configuration, dimensions, electrical characteristics, photometric performance, certifications and compliance status depend on the selected manufacturer and project specification. The technical values published on this page should not be treated as a substitute for the manufacturer's current approved Technical Data Sheet.

Final selection shall be based on the approved project specification, applicable aviation standards, authority requirements, manufacturer documentation and site conditions. Use of this page is also subject to the Legal Notice, Disclaimer & Terms of Use.

Standards and editions referenced on this site are listed on the Standards Reference page.