PAPI Power Supply
The electrical source that energizes the PAPI light units — from the Constant Current Regulator (CCR) that powers halogen lamps via series circuits, to dedicated LED drivers that provide regulated current to modern LED modules. Reliable power delivery ensures consistent intensity and uninterrupted glide slope guidance in all weather conditions.
Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.
What Is It?
The PAPI Power Supply encompasses the electrical systems that provide energy to the PAPI light units. The specific configuration depends on the type of light source used:
- Halogen PAPI Systems: Powered by a Constant Current Regulator (CCR) that supplies a regulated 6.6A current to the series circuit. Each PAPI unit is connected via an isolating transformer that steps down the voltage while maintaining the constant current. The CCR receives mains power (typically 115/230 VAC) and converts it to the required series current, with selectable intensity steps.
- LED PAPI Systems: May use a CCR (if designed for series circuit compatibility) with LED drivers in each unit, or a dedicated low‑voltage DC power supply that feeds the LED modules directly. In some modern systems, a central power supply unit converts mains AC to a regulated DC voltage (e.g., 24V or 48V) and distributes it to the LED units via a parallel or distributed power architecture.
- Portable PAPI: Uses battery packs (often rechargeable Li‑ion or lead‑acid) with integrated charging circuits, sometimes supplemented by solar panels for extended operation.
The power supply is critical to the performance and reliability of the PAPI system. It must deliver clean, stable power with precise current regulation to maintain the required luminous intensity and ensure that all units in the array produce consistent light output.
Purpose & Function
The power supply's purpose goes beyond simply keeping the lamps lit — PAPI works by a pilot comparing the relative brightness and colour of four units side by side, so what matters most is that every unit receives exactly the same, stable current as the others. If one unit runs even slightly dimmer because of an underpowered or poorly regulated supply, the red/white balance a pilot relies on to judge glide slope becomes distorted in a way that has nothing to do with the aircraft's actual position. This is why constant-current regulation, rather than simple constant-voltage power, is central to the design: it holds every unit in the array to the same output regardless of cable length or connection resistance differences between units. The same regulation also has to support clean switching between day, twilight, and night intensity steps without one unit lagging or overshooting relative to the others during the transition.
Power Supply Configurations
PAPI power supplies come in several configurations depending on the system type and installation environment:
CCR-Based (Halogen)
Constant Current Regulator supplies 6.6A to the series circuit. Isolating transformers at each unit step down voltage. Provides 3 or 5 brightness steps. Robust and proven, but less efficient than LED solutions.
LED Driver (Per Unit)
Each PAPI unit contains an integrated LED driver that converts the 6.6A series current (or a DC input) to the regulated current for the LED array. Often includes PWM dimming for intensity control and status monitoring.
DC Distributed (Modern)
A central rectifier converts mains AC to a regulated DC bus (24V or 48V). The DC is distributed to each PAPI unit, where local DC‑DC converters or linear regulators power the LEDs. Offers higher efficiency and simpler wiring.
Battery / Solar (Portable)
Rechargeable battery packs (Li‑ion or lead‑acid) with solar charging capability. Includes charge controllers, battery management systems, and DC‑DC converters to provide regulated power to the PAPI units.
Hybrid (CCR + LED)
Retrofit systems where a CCR is retained but halogen lamps are replaced with LED modules. The LED modules include specialized drivers that accept the 6.6A series current and provide PWM control, allowing gradual upgrade of existing infrastructure.
UPS / Backup
Uninterruptible Power Supply systems that provide battery backup to the PAPI power supply during mains failure. Critical for CAT II/III precision runways where continuous operation is mandatory.
Where Is It Used?
The PAPI power supply is an essential component of every PAPI installation, with variations for different operational requirements:
- Precision runways (CAT I, II, III) – CCR-based systems with UPS backup, providing reliable 6.6A series power and multiple intensity steps.
- Non‑precision runways – simpler CCR or DC power supplies, often with manual intensity control.
- Heliports – compact power supplies, sometimes with lower power ratings for helicopter PAPI units.
- Portable or temporary PAPI – battery or solar power supplies for rapid deployment in remote locations.
- Military airfields – ruggedized power supplies with high reliability and EMI filtering.
- Retrofit upgrades – LED drivers and power supplies that allow existing halogen PAPI systems to be upgraded to LED without replacing the entire infrastructure.
Installation & Location
The power supply for a permanent PAPI installation is housed in the CCR room or equipment shelter serving that runway, wired into the series circuit (or DC distribution, depending on topology) that feeds the wing bar, with UPS backup added on precision runways where continuous availability is mandated. Cabling runs from the shelter out to each unit on the bar via underground ducting and the same isolating transformers used elsewhere in the AGL network. On portable and temporary installations, the power supply is instead integrated into or mounted alongside the unit itself — a battery pack, solar panel, or small generator — sited close to the wing bar rather than in a fixed building, so the whole system can be set up and struck without permanent infrastructure. In every case, the supply's location is chosen to keep cable runs to the wing bar within the system's voltage-drop limits.
How Does It Work?
The PAPI power supply performs several critical functions to ensure reliable and consistent illumination:
- AC to DC/Current Conversion: For CCR‑based systems, the input mains AC is converted to a regulated 6.6A constant current, regardless of load variations. This is achieved using a saturable reactor, thyristor, or IGBT-based regulator. For DC‑distributed systems, the AC is rectified and filtered to produce a stable DC voltage.
- Intensity Control: The power supply receives brightness commands from the control unit (or ALCMS) and adjusts the output current or PWM duty cycle accordingly. In CCRs, this is done by switching transformer taps or electronically controlling the current setpoint. In LED drivers, it's typically achieved via PWM dimming.
- Protection: The power supply includes overcurrent, overvoltage, short‑circuit, and thermal protection to prevent damage to the PAPI units and the power supply itself. Faults are reported to the control system.
- Monitoring: The power supply monitors its own status (input voltage, output current, temperature) and, in advanced systems, the status of each connected PAPI unit. This data is made available to the control unit for diagnostics and maintenance planning.
- Isolation: In CCR‑based systems, isolating transformers at each PAPI unit provide galvanic isolation between the primary series circuit and the secondary lamp circuit, enhancing safety.
- Filtering: EMI filters and surge protection devices are integrated to protect the power supply from transients and to prevent electromagnetic interference with other airport systems.
System Architecture & Control Logic
The power supply is where the intensity command is actually converted into current — it receives its brightness setting from the control unit or ALCMS and adjusts either the CCR's output current (legacy series-circuit topology) or a PWM duty cycle (modern DC bus / LED-driver topology) to match. Sitting alongside that command path is a set of protection functions — overcurrent, overvoltage, short-circuit and thermal cutoffs — that run independently of the intensity logic and take precedence over it whenever a limit is exceeded.
Because a PAPI's glide-slope function depends on continuous, correctly-graduated illumination, the supply's monitoring — input voltage, output current, internal temperature, and, on advanced units, per-fixture status — feeds back into the same fault-reporting chain as the rest of the AGL system, so a developing problem is flagged to the control unit and ALCMS well before it becomes a hard outage.
ALCMS → Power Supply/CCR (+ Protection Logic) → Isolating Transformer → PAPI Lamps (status feedback)
CCR vs. DC‑Distributed Topology
Mains AC
115/230 VAC input
CCR
Regulates 6.6A constant current
Series Circuit
Same 6.6A loops through every unit
Isolating Transformer
Per unit — galvanic isolation
Halogen / LED Lamp
3 or 5 brightness steps via tap switching
Mains AC
115/230 VAC input
Central Rectifier
Converts AC to regulated 24/48 VDC
DC Bus
Distributed in parallel to each unit
Local DC‑DC / Driver
Per‑unit regulation, PWM dimming
LED Array
0–100% intensity via PWM duty cycle
Physical Construction
A CCR-fed halogen installation places the constant current regulator in an equipment room enclosure, converting mains input into a regulated series current fed out through cable glands to the primary loop, with each PAPI unit's isolating transformer built into its own base can or junction box along that loop. An LED PAPI system built around a central DC power supply instead houses a switch-mode power supply in a cabinet or equipment room, rectifying and regulating mains input down to a low DC voltage that is distributed by parallel wiring — a heavier-gauge cable than a series loop, since parallel distribution carries the full current to every branch point rather than a single shared loop current. Portable PAPI units carry their own sealed rechargeable battery pack and charge controller inside the fixture's own housing or a companion equipment box, with a solar panel, where fitted, mounted above or beside the unit and wired through a charge regulator to trickle-charge the battery during daylight. In every configuration, the power conversion and regulation electronics are housed separately from the light-emitting optics, connected to them only by the cable carrying the regulated current or voltage.
Technical Parameters
| Parameter | CCR (Halogen) | LED Driver (Per Unit) | DC Power Supply (Central) |
|---|---|---|---|
| Input Voltage | 115/230 VAC ±10%, 50/60 Hz | 6.6A AC (series) or 24/48 VDC | 115/230 VAC ±10%, 50/60 Hz |
| Output Type | 6.6A constant current (series circuit) | Regulated DC (LED current) | Regulated DC (24V or 48V) |
| Output Power | Up to 5 kVA (multiple units) | 50W – 150W per unit | 200W – 1 kW (multiple units) |
| Intensity Steps | 3 or 5 (2.8A – 6.6A) | PWM dimming (0–100%) | Controlled via communication bus |
| Efficiency | 75% – 85% | 85% – 95% | 90% – 95% |
| Protection | Overcurrent, short‑circuit, overtemperature | Overcurrent, overvoltage, reverse polarity, thermal | Overcurrent, overvoltage, short‑circuit, overtemperature |
| Communication | Modbus, proprietary (optional) | Modbus, DALI, or 0‑10V | Modbus, BACnet, or Ethernet |
| Cooling | Forced air (fans) or natural convection | Natural convection (heatsink) | Forced air or natural convection |
| Operating Temperature | -20°C to +50°C (indoor) | -40°C to +70°C (outdoor) | -20°C to +60°C (indoor) |
| Protection Class | IP20 (indoor) / IP65 (outdoor optional) | IP67 (integrated in fixture) | IP20 (indoor) / IP65 (outdoor enclosure) |
| Dimensions (typical) | 600 × 500 × 300 mm (CCR) | 50 × 30 × 20 mm (driver module) | 400 × 300 × 150 mm |
| Weight | 30 – 100 kg (CCR) | 0.2 – 0.5 kg | 5 – 15 kg |
Electrical Requirements
| Parameter | Requirement |
|---|---|
| Input Power | 115/230 VAC ±10%, 50/60 Hz (CCR and central DC supply); 24/48 VDC input for portable configurations |
| Circuit Protection | Dedicated branch breaker sized to the supply's rated input current, with upstream disconnect |
| Grounding | Enclosure/chassis bonded to protective earth, tied into the equipment room's earthing grid |
| Output Circuit | Series constant‑current loop (halogen/CCR) or parallel DC distribution (LED) — wired per system topology, not interchangeable |
| Isolation | Isolating transformer required per field unit on CCR‑fed loops; output isolated from mains on all topologies |
| Surge / Lightning Protection | Surge protection device on the AC input; bonded lightning protection for exposed outdoor cabling |
| Backup Power | UPS or battery backup sized to the installation's runway category, transferring without exceeding output spec |
| Cable Sizing | Feeder and distribution cable sized to keep voltage drop within system limits over the longest run |
Applicable Standards
ICAO Annex 14
PAPI power supply requirements and reliability
FAA AC 150/5345-28
PAPI system – power supply specifications
FAA AC 150/5345-53
Airport Lighting Equipment Certification Program (qualification listing for PAPI power supplies)
IEC 61000-6-2
EMC immunity for industrial environments
IEC 61000-6-4
EMC emission for industrial environments
UL 508
Industrial control equipment – safety standards
Installation Requirements
Shelter or Equipment Room Siting
CivilFor a permanent installation, house the power supply in the CCR room or equipment shelter serving the runway; for portable or temporary PAPI, site the battery pack, solar panel, or generator close to the wing bar itself rather than in a fixed building.
Cable Route Within Voltage-Drop Limits
ElectricalRun underground ducting from the shelter to each wing bar unit, choosing the supply's location so the cable run stays within the system's voltage-drop limits.
Series Circuit or DC Distribution Wiring
ElectricalWire the supply into the series circuit or DC distribution feeding the wing bar, matching the topology (CCR-fed halogen loop vs. parallel-wired LED DC distribution) the installation uses.
Isolating Transformer Matching
ElectricalConfirm each wing bar unit's isolating transformer wattage matches the fixture and the loop's rated current step, for CCR-fed installations.
UPS Backup Sizing
MechanicalAdd UPS backup sized for the installation on precision runways where continuous availability is mandated.
Portable Power Source Siting
MechanicalFor portable units, mount the solar panel (where fitted) with a clear sky view above or beside the unit and confirm the charge regulator is wired to trickle-charge the battery correctly.
Enclosure Sealing Check
MechanicalConfirm cable glands and enclosure seals are fully seated before the shelter or unit housing is closed, since power conversion electronics are moisture-sensitive.
Pre-Energisation Sign-off
DocumentationRecord supply location, cable route, wiring topology, and UPS or portable power source details as-built before the installation is closed out.
Testing & Commissioning
Output Voltage/Current Verification
EnergisationConfirm CCR series current, LED driver output current, or DC supply output voltage matches rated values at each configured step before connecting live PAPI units.
Load Test at Rated Output
EnergisationRun the supply at full rated load (up to 5 kVA for CCR, rated wattage for LED drivers/DC supplies) and confirm stable output with no excessive temperature rise.
Protection Trip Test
EnergisationSimulate overcurrent, short-circuit, and overtemperature conditions and confirm the unit trips and recovers correctly without damage.
Efficiency Spot-Check
EnergisationMeasure input vs. output power at a representative load point and confirm efficiency falls within the rated 75–95% band for the supply type.
Communication & Control Verification
EnergisationConfirm Modbus/DALI/BACnet/0-10V control signals correctly command intensity steps or dimming level, matching the value shown at the local display.
Cooling System Check
Final AcceptanceConfirm forced-air fans run correctly or natural convection paths are unobstructed, since inadequate cooling shortens component life under sustained load.
Insulation Resistance Test
Pre-EnergisationMegger-test the supply's input and output circuits against earth to confirm insulation resistance clears the acceptable minimum before first energisation.
Documentation & As-Built Sign-off
Final AcceptanceRecord output verification, load test, and protection trip results alongside the installed configuration in the commissioning dossier for handover.
Inspection & Maintenance
CCR Tap Switching Test
AnnualVerify the constant current regulator switches taps correctly across the intensity range.
Thermal Performance Check
Semi-annualConfirm the LED driver is operating within its rated temperature range to prevent overheating.
Input Voltage Stability Check
AnnualVerify input voltage remains stable, since fluctuations can affect regulated output.
Battery Check
AnnualFor portable units, check battery condition and replace before degradation affects runtime.
Series Circuit Loading Verification
AnnualConfirm the series circuit loading remains within the supply's rated capacity.
Common Field Issues
CCR Tap Switching Failures
In older CCRs, the mechanical tap switches or relays can fail, resulting in incorrect intensity steps. This can cause the PAPI to be too bright or too dim. Regular inspection and replacement of worn contactors is essential. Consider upgrading to solid‑state switching for reliability.
LED Driver Overheating
LED drivers integrated into the PAPI unit can overheat if the heatsink is clogged with dust or if the ambient temperature is high. This can reduce the driver's life or cause thermal shutdown, leading to intermittent operation. Regular cleaning and thermal paste renewal are recommended.
Input Voltage Fluctuations
Mains voltage dips or surges can affect the output of the power supply, especially in CCRs without active regulation. Use a UPS or voltage stabilizer for critical installations, and ensure the CCR has wide input voltage tolerance.
Battery Degradation (Portable)
In battery‑powered PAPI systems, battery capacity decreases over time and with temperature. Regular capacity testing and timely replacement of batteries are essential to ensure the system can operate for the required duration. Use battery management systems that monitor health and provide early warnings.
Communication Interference
In systems where the power supply communicates with the control unit (e.g., for dimming or status monitoring), electrical noise can interfere with communication, causing erratic behavior. Use shielded cables and proper grounding to minimize interference.
Incorrect Series Circuit Loading
If the total load on the series circuit (number of PAPI units, wattage of lamps) is not matched to the CCR rating, the output current may not be stable. Always ensure the CCR is correctly sized for the load and that the circuit is properly terminated.
Troubleshooting Guide
Intensity Steps Incorrect or Erratic
Intermittent Operation or Thermal Shutdown (LED Systems)
Output Unstable During Mains Disturbances
Portable System Runtime Shorter Than Expected
Erratic Dimming or Status Reporting
Failure Modes & Root Causes
Step Selection Contactor Fault
Overtemperature Protection Trip
Output Regulation Instability
Portable Battery Degradation
Dimming / Status Reporting Fault
Safety & Operational Notes
High Open-Circuit Series Voltage
Electrical SafetyOn CCR-fed halogen or LED PAPI systems, the series loop across the four-unit array can present several kV open-circuit; de-energise and lock out the CCR at its supply, and verify zero energy at any output terminal or isolating transformer connection before touching it.
Residual Stored Charge
Electrical SafetyInternal filter capacitors in a central DC supply configuration can retain a dangerous charge after shutdown; observe the manufacturer's specified discharge time, or confirm discharge with a rated meter, before opening the enclosure.
Hot Surfaces
Personnel SafetyAllow halogen lamp housings, isolating transformers, and CCR heatsinks to cool before handling after active operation; halogen PAPI units in particular retain significant heat.
Portable/Battery Configuration Hazards
Personnel SafetyOn portable PAPI configurations fed from a 24/48VDC battery source, treat the battery as a high-current short-circuit hazard even when the unit is switched off; use insulated tools and follow the manufacturer's disconnect sequence.
Glide-Path Guidance Is Safety-Critical — Coordinate Before Isolating
OperationalPAPI provides visual glide-path guidance on final approach; taking any unit or the shared power supply out of service requires ATC/airside coordination and a NOTAM before isolation, since aircraft may be relying on it for approach guidance.
Insulation Test Before Re-Energisation
Electrical SafetyMegger test the series loop before restoring power after any cable, connector, or unit work, since a residual fault at re-energisation can trip the CCR or leave one or more units dark or at reduced intensity.
Restore to Compliant State
ComplianceConfirm every unit in the array is illuminated at the correct intensity step and that beam angle/aim has not been disturbed before closing out the work and cancelling the associated NOTAM.
Engineering & Expert Notes
Verify Current Regulation Across the Full Step Range, Not Just at 100%
ElectricalA CCR that regulates cleanly at full brightness can still show poor current stability on its lowest intensity step, where control loop performance is often weakest. Check regulation and ripple across every step used operationally, not just the step the acceptance test happens to default to.
Size Isolating Transformers to the Installed Load, Not the Catalogue Default
DesignWhen a system migrates from halogen to LED PAPI units on the same series circuit, reusing the original transformer VA rating sized for the old lamp load leaves the transformer significantly oversized for the new draw, which can itself introduce regulation and efficiency issues; re-select based on actual installed load.
Mixed Series and Parallel Architectures Need Separate Fault Logic
DesignWhere an LED PAPI array mixes a series-circuit CCR feed with a parallel DC distribution stage for the LED drivers, a single fault-detection scheme borrowed from a pure series or pure parallel design usually misses failure modes unique to the hybrid architecture; verify the monitoring logic was actually designed for the specific topology installed.
Battery Capacity Fade on Portable PAPI Is Non-Linear
ReliabilityRechargeable battery packs on portable PAPI units hold their rated runtime reasonably well for most of their service life and then fall off sharply near end-of-life; a runtime check that looked fine a few months ago isn't a reliable predictor of current capacity, so test runtime directly rather than trusting age-based replacement schedules alone.
Solar Supplement Sizing Assumes Worst-Case, Not Average, Conditions
DesignA solar-supplemented battery system sized against average regional insolation will run short during a stretch of overcast days; size for worst-case consecutive low-sun days for the deployment location and season, since portable PAPI is often needed precisely during poor-visibility periods.
An Intensity Complaint May Be a Power Supply Issue, Not an Optical One
TroubleshootingA uniform, array-wide intensity shortfall that all units share equally points toward the shared power supply or CCR rather than a coincidental optical fault in every unit; check the supply's actual delivered current before pulling and testing individual optical assemblies.
Frequently Asked Questions
Short answers about PAPI power supplies: CCR and LED configurations, regulation, intensity control, standards, testing, maintenance and common faults.
Q1What is a PAPI power supply?
The PAPI power supply is the electrical system that energises the PAPI light units. For halogen PAPI it is a Constant Current Regulator (CCR) feeding a series circuit; for LED PAPI it is either a CCR with LED drivers in each unit or a central DC power supply; and portable PAPI uses battery packs, sometimes with solar charging. It must deliver clean, stable power so every unit in the array produces the same light output.
Q2Why does a PAPI need constant current regulation rather than constant voltage?
A pilot judges the glide slope by comparing the relative brightness and colour of the four units, so every unit must receive exactly the same, stable current. If one unit runs slightly dimmer, the red/white balance is distorted in a way that has nothing to do with the aircraft's position. Constant-current regulation holds every unit to the same output regardless of cable length or connection resistance differences between units.
Q3What is the difference between a CCR-fed and a DC-distributed PAPI supply?
A CCR keeps a single series current loop (6.6 A) and isolates each lamp locally with an isolating transformer, so one failed transformer does not affect the rest of the circuit. A DC-distributed system uses a central rectifier to create a regulated 24 V or 48 V DC bus, distributed in parallel to each unit where a local DC-DC converter or driver powers the LEDs. That trades the shared-loop resilience for higher efficiency and simpler wiring.
Q4How is PAPI intensity controlled by the power supply?
The supply receives brightness commands from the control unit or ALCMS. In CCRs this is done by switching transformer taps or electronically controlling the current setpoint, giving 3 or 5 steps between 2.8 A and 6.6 A. In LED drivers it is typically done by PWM dimming from 0 to 100%. Protection functions such as overcurrent, overvoltage, short-circuit and thermal cutoffs run independently and take precedence over the intensity logic.
Q5What are the typical specifications of a PAPI power supply?
A CCR for halogen PAPI typically takes 115/230 VAC ±10% at 50/60 Hz, outputs 6.6 A constant current, handles up to 5 kVA and has an efficiency of 75% to 85%. A per-unit LED driver is typically 50 W to 150 W with 85% to 95% efficiency, and a central DC supply is typically 200 W to 1 kW with 90% to 95% efficiency. Operating temperature and protection class vary by type, from IP20 indoor to IP67 for drivers integrated in the fixture.
Q6Do PAPI power supplies need UPS or battery backup?
UPS or battery backup is added on precision runways (CAT II/III) where continuous operation is mandatory, and it must be sized for the installation and transfer without exceeding the output specification. Non-precision runways often use a simpler CCR or DC supply. Portable or temporary PAPI instead uses its own battery pack, sometimes supplemented by solar panels.
Q7Which standards apply to PAPI power supplies?
The main references are ICAO Annex 14, FAA AC 150/5345-28 (PAPI system power supply specifications), FAA AC 150/5345-53 (Airport Lighting Equipment Certification Program), IEC 61000-6-2 and IEC 61000-6-4 for EMC immunity and emission, and UL 508 for industrial control equipment safety. Always verify the current edition and your aerodrome's approved requirements.
Q8How should a PAPI power supply be tested at commissioning?
Confirm the CCR series current, LED driver output current or DC supply voltage matches rated values at each configured step before connecting live PAPI units. Then run a full-load test, simulate overcurrent, short-circuit and overtemperature conditions to confirm protection trips and recovers, spot-check efficiency, verify Modbus, DALI, BACnet or 0-10 V control against the local display, check cooling, and megger-test input and output circuits against earth. Record the results in the commissioning dossier.
Q9How often should a PAPI power supply be inspected and maintained?
Typical intervals are annual for CCR tap-switching tests, input voltage stability checks, series circuit loading verification and, for portable units, battery checks, and semi-annual for LED driver thermal performance checks. Your airport's approved maintenance programme takes precedence.
Q10Why are my PAPI intensity steps incorrect or erratic?
The usual cause in older CCRs is failure of the mechanical tap switches or relays. Inspect them for wear, pitting or failure to actuate, and compare the actual output current against the commanded step. Replace worn contactors, or upgrade to solid-state switching for better reliability. A uniform, array-wide intensity shortfall shared equally by all units also points toward the shared power supply or CCR rather than an optical fault in every unit.
Q11What safety precautions apply when working on a PAPI power supply?
On CCR-fed systems the series loop can present several kV open-circuit, so de-energise and lock out the CCR and verify zero energy before touching any output terminal or isolating transformer. Central DC supplies can retain charge in filter capacitors, and battery sources on portable units are a high-current short-circuit hazard. PAPI guidance is safety-critical, so taking a unit or the shared supply out of service requires ATC/airside coordination and a NOTAM, and the series loop should be megger-tested before re-energising.
Related Components
Go Beyond the Component. Understand the Complete AGL System.
You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.
Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.
Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.
Your next step in AGL starts here.
Need expert guidance on PAPI power supply selection, installation, or troubleshooting?
Precision AGL Academy provides advice on CCR sizing, LED driver integration, and power reliability for PAPI and other AGL systems.
Follow the Academy
Important Notice, Disclaimer & Limitation of Liability
Please read before relying on any content on this page.
- Purpose and intended users. This page on PAPI Power Supply is an independent educational and informational reference for competent, suitably trained and authorised airfield ground lighting (AGL) and aerodrome electrical personnel. It is not professional engineering, legal or regulatory advice, and using it does not create any professional or client relationship.
- Safety. Work on series circuits, constant current regulators (CCRs), isolating transformers, cables, connectors and lighting equipment can be fatal. Always apply the aerodrome’s permit-to-work and isolation/LOTO procedures, prove dead, use correctly rated instruments and PPE, and follow the manufacturer’s instructions. Nothing here authorises work on live equipment or the bypassing of any safety device or interlock.
- Aviation operations. Nothing here authorises installation, modification, energisation, adjustment, return to service, a change of operating category (CAT I/II/III), a NOTAM or any aerodrome certification or approval decision. These rest with the aerodrome operator, the air navigation service provider and the competent regulator.
- Specifications, ratings and typical values. Descriptions, parameters, ratings, dimensions, photometric values, wattages, service lives, maintenance tasks and intervals, failure modes, certifications (for example CE, FCC, UL or IEC marks) and part or type designations are general, typical and indicative. They may not match any particular product, make, model or version, and they are not a datasheet, design, specification, selection, sizing, procurement or acceptance criterion. The manufacturer’s current documents, the approved design and the project specification prevail.
- Standards and regulations. References to ICAO, FAA, IEC, IEEE, ISO, BIS, DGCA and other standards are paraphrased summaries for orientation only. They may be incomplete or out of date, and standards are revised from time to time. Consult the current official editions. Following this content does not guarantee compliance with any law, standard or regulatory approval, and the regulator’s requirements always prevail.
- No warranty. Content is provided “as is” and “as available”, without warranty of any kind, express or implied, including accuracy, completeness, currency or fitness for a particular purpose. Real installations differ in design, equipment make and model, age and condition.
- Limitation of liability. To the fullest extent permitted by applicable law, Precision AGL Academy, Precision AGL Solutions and their owners, authors and contributors are not liable for any injury, death, loss, damage, downtime, penalty or regulatory consequence, whether direct or indirect, arising from the use of, reliance on, or inability to use this content. Nothing in this notice excludes or limits any liability that cannot lawfully be excluded or limited.
- Independence, brands and no endorsement. This is an independent publication. It is not affiliated with, sponsored by or endorsed by ICAO, the FAA, the IEC, DGCA, AAI, any airport, regulator, supplier or equipment manufacturer. Third-party names, product designations, standard designations and trademarks (including Megger®, Siemens, Eaton, Crouse-Hinds, ADB SAFEGATE, Fluke, ABB and Honeywell) belong to their respective owners and are used only for identification and description. Mention of a brand, product or supplier is not a recommendation, and we do not sell, supply or quote for any component described.
- Images and third-party content. Images and illustrations are shown to help identify the type of component. They may show products of various manufacturers, may not depict the exact item described, and are not a statement about any product’s quality, approval or performance. Copyright and trademarks in third-party images, logos and photographs belong to their respective owners and are not claimed as ours. If you are a rights holder and want an image removed, replaced or credited, email precisionaglsolutions@gmail.com with the page address and we will act promptly.
- Training and services. Mentions of training, courses, consultation, advice, selection, installation, calibration or other support, including the “Learn…Certify” pathway, describe learning stages and are not an offer, quotation, tender or promise of any result. Contacting us or our replying creates no engagement or duty of care; an engagement exists only under a written agreement. We are not a regulator or certification body, and completing any course or reading this content is not a certification, accreditation or authorisation to work on any aerodrome.
- Copyright, privacy and corrections. © 2026 Precision AGL Academy. All rights reserved. Text, structure, compilations and diagrams may be viewed for personal reference and internal training only; any other copying, republication or commercial use needs our written permission. If you email, telephone or message us, we use your details only to respond and handle your matter, in line with applicable Indian law including the Digital Personal Data Protection Act, 2023; please do not send confidential or security-sensitive information. To display this page your browser requests fonts, icons and images from third-party servers, which receive your IP address and browser details under their own policies. Content is reviewed periodically with no obligation to update. To report an error, safety concern or rights issue, write to precisionaglsolutions@gmail.com.