No Entry Sign
A red mandatory instruction sign with white text and symbol, indicating areas where entry is prohibited for aircraft or vehicles. Used to prevent unauthorised access to restricted areas, runways, taxiways, or other critical zones.
Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.
What Is It?
A No Entry Sign is a red mandatory instruction sign with white text and/or symbols that indicates areas where entry is prohibited for aircraft, vehicles, or personnel. It is a critical safety component used to prevent unauthorised access to restricted zones such as active runways, taxiways under construction, maintenance areas, or other hazardous locations. The sign typically features a red circle bearing a white horizontal bar (the international "no entry" symbol), sometimes supplemented by text such as "NO ENTRY" or "DO NOT ENTER". It is part of the airfield surface movement guidance system and is used to enforce access restrictions and enhance safety.
Purpose & Function
Unlike signs that guide movement toward a destination, the no entry sign's function is purely prohibitive: it tells the pilot or vehicle driver that the route ahead is closed, with no conditional clearance path implied. This absolute framing matters because the areas it protects, whether a closed taxiway segment, a construction zone, or a hazardous location, carry a level of risk that leaves no room for the kind of judgement calls a direction or information sign might allow. The internationally standardised red-circle-and-bar symbol is chosen so the message reads instantly and consistently regardless of the operator's language, reinforcing rather than replacing any physical barriers, markings, or lighting also used to close off the same area.
Where Is It Used?
Installed at the entrances to restricted areas, including taxiways that are closed, runways that are under maintenance, construction zones, equipment storage areas, and other locations where access is prohibited. They are placed on the side of the taxiway or roadway, typically at a height of 1.5 to 2 metres above the pavement, on a frangible support. No Entry signs are used at all airfields and are especially critical at busy airports to prevent runway incursions and ensure safety during maintenance activities.
Installation & Location
Posts are founded at the entrance to the closed taxiway, runway under maintenance, construction zone, or restricted area the sign protects, set back clear of wingtip clearance while sitting close enough to the closure point that approaching traffic cannot proceed past it unnoticed. Because these signs mark temporary as well as permanent closures, foundations for construction and maintenance-period signs are often a portable frangible base rather than a cast-in post, allowing the sign to be relocated as the closure boundary moves through a project; permanent no-entry locations use the same fixed frangible post foundation as other mandatory signs. Illuminated panels are cabled from the nearest available distribution point; portable units typically rely on retroreflective sheeting or battery-powered LED rather than a permanent cable run.
How Does It Work?
The sign displays the international "no entry" symbol (a red circle with a white horizontal bar) and/or white text on a red background, following ICAO Annex 14 and FAA standards. The text may include "NO ENTRY", "DO NOT ENTER", or specific restrictions such as "AIRCRAFT PROHIBITED". The sign may be non‑illuminated (using retroreflective sheeting) or internally illuminated (LED) for nighttime visibility. The sign is positioned to be clearly visible to pilots and vehicle drivers, warning them that entry is not permitted. It is mounted on a frangible support to minimise aircraft damage in case of collision.
System Architecture & Control Logic
A no entry sign follows the same two-model split seen across AGL signage. Where illuminated, it is wired onto the constant current series circuit for that section of taxiway or apron: an ALCMS selects the required brightness step, the CCR regulates the entire loop to a fixed current, and the sign panel — fed through its own isolating transformer — burns at the same intensity as every other fixture on that loop, with a voltage rise at constant current flagging a loop-level fault rather than one isolated to the sign. Where the sign instead relies on retroreflective sheeting, there is no electrical control path at all — the red circle-and-bar symbol becomes conspicuous only because the sheeting reflects an approaching aircraft's or vehicle's landing lights straight back to the viewer, meaning there is no ALCMS command, no CCR current, and no loop for a fault to appear on. Given that a no entry sign has no associated clearance procedure (see the System Logic section below), maintenance teams should treat the illuminated variant's loop fault with the same urgency as a stop bar failure, since its message admits no negotiated response.
Illuminated variant: ALCMS → CCR → Loop → Sign Panel. Retroreflective variant: no electrical path at all.
Why "No Entry" Has No Clearance Path
Physical Construction
The panel is an extruded aluminium frame around a Class 1/2 retroreflective face or, for illuminated versions, a translucent acrylic panel backlit by an internal LED module, in each case carrying the white-on-red mandatory format. The legend combines the international red-circle-with-white-bar "no entry" symbol alongside or in place of the "NO ENTRY" / "DO NOT ENTER" text, giving the sign a dual reading path — symbol for instant recognition, text for confirmation — that most other mandatory signs on the airfield don't need. The frame is gasket-sealed and bolted to a frangible coupling on a below-grade base plate so it shears away cleanly if struck, the same mounting convention as every other holding-position and instruction sign in the library.
Technical Parameters
| Parameter | Typical Value |
|---|---|
| Colour | Red background, white text and symbol (ICAO / FAA) |
| Symbol | Red circle with white horizontal bar (international no entry) or standard text |
| Dimensions | Face width ~1.46 m (code 1–2) to ~1.94 m (code 3–4); face height 0.3–0.6 m, per ICAO Annex 14 legend/code table |
| Text Height | 200 / 300 / 400 mm per ICAO Annex 14, set by aerodrome reference code (1–2 / 3 / 4) — not a viewing-distance choice |
| Text Content | "NO ENTRY", "DO NOT ENTER", or equivalent |
| Illumination | Non‑illuminated (retroreflective) or internally illuminated (LED) |
| Retroreflective Class | Class 1 or Class 2 (ASTM D4956) |
| Mounting Height | 1.5–2 m above pavement |
| Frangible Support | Breakaway coupling or frangible post |
| Protection Class | IP65 (weatherproof) |
| Operating Temperature | -40°C to +60°C |
Electrical Requirements
| Requirement | Typical Value |
|---|---|
| Circuit Type | Series circuit, constant current (CCR fed) — illuminated variant only |
| Rated Series Current | 6.6A (3 to 5-step: 2.8A / 3.4A / 4.1A / 5.2A / 6.6A) |
| Isolation | Via dedicated isolating transformer, not directly connected to series loop |
| Transformer Secondary | Matched to sign wattage; sized to series circuit rating |
| Cable Type | L-824 single-conductor, direct-burial rated, 5kV or 600V per circuit design |
| Connector | L-823 primary connector, submersible-rated splice |
| Insulation Resistance | ≥ 50 MΩ (megger test, cable-to-ground) |
| Earthing/Grounding | Sign body and base can bonded to airfield earth grid |
| Fault Protection | CCR-level ground fault and open-circuit detection |
| Non-Illuminated Variant | No electrical supply required — passive retroreflective panel only |
Photometric Requirements
| Parameter | Typical Value |
|---|---|
| Background Luminance (Red) | ≥ 30 cd/m² average (illuminated variant), uniformity ratio ≤ 10:1 (max:min) |
| Legend/Symbol Luminance (White) | ≥ 150 cd/m² average |
| Legend-to-Background Contrast Ratio | 5:1 to 10:1 per ICAO Annex 14 Attachment A |
| Retroreflective Coefficient (Non-Illuminated Variant) | RA ≥ 50 cd/lux/m² (white), ≥ 15 cd/lux/m² (red) per ASTM D4956 Class 1/2 |
| Chromaticity (Red Background) | Within ICAO Annex 14 aeronautical red boundary (CIE coordinates) |
| Chromaticity (White Legend/Symbol) | Within ICAO Annex 14 white boundary (CIE coordinates) |
| Viewing Angle | ± 5° horizontal, legible from typical vehicle/cockpit eye height |
| Luminance Tolerance | ± 25% of rated value across the panel face |
| Maintenance Factor | ≥ 50% of new-panel luminance before lamp/LED or sheeting replacement is due |
| Test Method | Luminance meter/photometer at normal and oblique angles, or retroreflectometer for the non-illuminated variant |
Applicable Standards
ICAO Annex 14
No entry sign colours, dimensions, and placement
FAA AC 150/5340-18
Standards for Airport Sign Systems — siting, design, and colour convention for this sign type
FAA AC 150/5345-44
Equipment/fixture specification for the sign unit itself (siting, design and colour are governed by AC 150/5340-18 above)
ASTM D4956
Retroreflective sheeting performance standards
IEC 60598
Luminaire requirements for illuminated signs
Installation Requirements
Setting-Out & Siting Survey
CivilSurvey and mark the sign position from the design/siting drawing before excavation, confirming clearance from the taxiway/runway edge safety area and any frangibility height limit.
Foundation / Base Plate Installation
CivilExcavate and set the base plate or footing to design depth, keeping the finished mount level and within the frangible height limit for the sign's location.
Frangible Mount Fitting
MechanicalFit the frangible post or breakaway coupling and torque to the specified value, confirming it shears as designed under lateral load and does not bind.
Cable Route & Connector Termination
ElectricalWhere the sign is internally illuminated, lay the duct/cable route to the panel and terminate the L-823 connector per manufacturer procedure, keeping the splice fully submersible-rated before backfill.
Isolating Transformer Matching
ElectricalWhere the sign is internally illuminated, confirm the isolating transformer wattage and ratio match the panel and the series circuit's rated current step before connection.
Panel Legend & Content Setting
QualityBefore the panel is fixed and the position closed out, confirm the red circle-and-bar symbol (and any "NO ENTRY" text) is correctly formed and unobstructed, since this sign carries no separate clearance procedure and must be unambiguous at first sight.
Retroreflective Sheeting Application
MechanicalApply and inspect the retroreflective sheeting for correct grade, alignment, and freedom from bubbles or edge lifting before the panel is mounted.
Pre-Backfill Sign-off
DocumentationRecord base/footing position, frangible coupling torque, cable route, and panel content as-built before backfill, since these are not inspectable once the site is closed.
Testing & Commissioning
Insulation Resistance (Megger) Test
Pre-EnergisationWhere the sign is internally illuminated, megger-test the isolating transformer and internal wiring before the circuit is energised, confirming insulation resistance clears the acceptable minimum ahead of backfill.
Loop Continuity & Resistance Test
Pre-EnergisationFor an illuminated installation, verify series loop continuity through the sign and record loop resistance, ruling out open circuits or high-resistance splices before first energisation.
Primary/Secondary Voltage Verification
EnergisationWith the CCR energised, confirm secondary voltage at the illuminated sign's L-823 connector matches the transformer's rated ratio at the commissioned current step.
CCR Brightness Step Response
EnergisationCycle the CCR through every intensity step and confirm an illuminated panel responds correctly at each, ruling out a marginal transformer or a loose connection.
Retroreflectivity / Luminance Verification
Final AcceptanceMeasure sheeting retroreflectivity with a retroreflectometer against ICAO/FAA commissioning minimums; where the panel is internally illuminated, also verify luminance and colour uniformity with a luminance meter.
Legend & Content Verification
Final AcceptanceConfirm the red circle-and-bar symbol (and any "NO ENTRY" text) is correctly formed and unobstructed, since this sign carries no separate clearance procedure and must be unambiguous at first sight.
Frangible Coupling & Mounting Verification
Pre-EnergisationConfirm the frangible coupling, base depth, and panel height meet as-built tolerances before the site is finally backfilled.
Documentation & As-Built Sign-off
Final AcceptanceRecord retroreflectivity/luminance readings, and (where illuminated) insulation, continuity, and voltage readings, alongside as-built position in the commissioning dossier for handover.
Inspection & Maintenance
Retroreflectivity Check
AnnualMeasure sheeting retroreflectivity with a retroreflectometer against ICAO / FAA minimums, and budget for sheeting replacement roughly every 5–7 years.
Illumination System Test
AnnualTest internal LED or fluorescent illumination for uniform, even lighting so the sign remains legible at night, especially ahead of low-visibility seasons.
Frangible Coupling Inspection
AnnualCheck the coupling or post for brittleness or corrosion and replace per manufacturer schedule to preserve breakaway performance on impact.
Seal & Cable Gland Check
AnnualInspect housing seals and cable glands for degradation, since moisture ingress through damaged seals is a leading cause of corrosion and electrical faults.
Sign Face Cleaning
QuarterlyClean dirt, de-icing fluid residue, and rubber deposits off the sign face to keep both reflectivity and legibility within spec.
Insulation Resistance Test
AnnualMegger-test internal wiring and any isolating transformer to confirm insulation resistance stays above minimum, catching moisture ingress early.
Common Field Issues
Retroreflective Sheeting Degradation
UV exposure, weathering, and abrasion can reduce reflectivity, making the sign difficult to read at night or in low visibility. Regular inspection and replacement (typically every 5–7 years) is essential.
Internal Illumination Failure
LED modules inside illuminated signs can fail, reducing visibility at night. Regular testing of the illumination system and replacement of failed components is required.
Frangible Support Fatigue
Breakaway couplings can become brittle over time due to weather and vibration. Regular inspection and replacement as per manufacturer guidelines are required to ensure breakaway performance.
Moisture Ingress
Water ingress through seals can cause corrosion and electrical faults. Routine seal checks and use of desiccants are recommended.
Troubleshooting Guide
Symbol or Text Unreadable at Night, Fine by Day
Illuminated Sign Dark or Flickering
Moisture or Condensation Inside Housing
Sign Leaning, Loose, or Misaligned
Failure Modes & Root Causes
LED Panel / Internal Light Source Failure
Retroreflective Sheeting Degradation
Frangible Coupling Fatigue / Impact Damage
Portable Unit Battery Depletion
Power/Circuit Connector Degradation
Safety & Operational Notes
Circuit Isolation Before Access
Electrical SafetyDe-energise and lock out the feeder circuit at the CCR or panel, then verify zero energy at the base can before opening the housing or handling cable connectors.
Airside Work Coordination
OperationalAny work on or near the movement area requires ATC/airside coordination and a NOTAM where the sign will be dark, obscured, or out of tolerance, with vehicle and personnel movement kept clear of the taxiway or runway strip per the aerodrome's safety management procedures.
Frangibility Not to Be Defeated
MechanicalNever substitute the frangible coupling with a rigid fitting or over-torque it during installation or repair; the coupling must still shear cleanly on aircraft impact to limit damage under the frangibility requirement.
FOD Control at the Base
OperationalKeep tools, fasteners, and removed gaskets accounted for at all times when the base can or housing is open, and secure or remove any loose material before reinstating the sign, to prevent foreign object debris on the movement area.
Insulation Test Before Re-Energisation
Electrical SafetyAfter any cable, connector, or panel work, megger test the affected circuit before restoring power, since a residual fault at re-energisation can trip the feeder circuit or damage healthy units on the same loop.
PPE & Grounding
Personnel SafetyUse insulated tools and appropriate PPE when working on circuit connections, and confirm the sign housing and base can are bonded/grounded per the electrical design before reconnecting the circuit.
Portable Unit Battery Management
OperationalFor portable or temporary units, check and log battery state at each inspection and replace before the manufacturer's rated runtime is reached, since a depleted battery silently removes the sign's conspicuity without an obvious fault indication.
Engineering & Expert Notes
Log Battery Swaps on the Unit Itself, Not Only in the System
MaintenanceFor portable units, a tag showing the last battery-change date on the sign itself lets a field crew spot an overdue unit at a glance, rather than depending on someone checking the maintenance system before every shift.
A Blown-Over Portable Unit Is Still a FOD Item
OperationalA lightweight portable no-entry sign knocked over by prop wash or wind becomes foreign object debris just like a fixed sign. Secure or weight portable units per the manufacturer's wind rating for that location.
Confirm Whether a Given Unit Is Permanent or Temporary Before Scheduling Maintenance
OperationalPermanent no-entry signage and temporary work-related units are managed on different maintenance cycles — confirm which one you're looking at before applying a standard inspection interval.
Position Relative to the Restriction Boundary Matters More Than Legibility
ComplianceA perfectly legible sign in the wrong position relative to the actual restricted boundary is arguably worse than a faded one in the right place. Verify against the current restriction survey, not just sign condition.
Treat Illumination Loss With the Same Urgency as a Holding Sign
OperationalBecause this sign marks a prohibition rather than just information, an illuminated unit going dark deserves the same response urgency as a mandatory holding sign — not standard sign-maintenance backlog.
Fixed-Unit Frangibility Discipline Still Applies
MechanicalFor permanently mounted no-entry signs, standard frangible-coupling inspection and replacement discipline still applies — the restricted-area designation doesn't change the underlying mechanical requirements.
Frequently Asked Questions
Short answers about the no entry sign: purpose, siting, power, standards, maintenance and common faults.
Q1What is a no entry sign?
A no entry sign is a red mandatory instruction sign with white text and/or symbols that shows where entry is prohibited for aircraft, vehicles or personnel. It protects areas such as closed taxiways, runways under maintenance, construction zones and other hazardous locations, and it is part of the airfield surface movement guidance system.
Q2What does a no entry sign look like?
It shows the international no entry symbol, a red circle with a white horizontal bar, and/or white text on a red background. The wording may be NO ENTRY, DO NOT ENTER or a specific restriction such as AIRCRAFT PROHIBITED.
Q3Where are no entry signs installed?
At the entrances to restricted areas: closed taxiways, runways under maintenance, construction zones and equipment storage areas. They stand at the side of the taxiway or roadway, typically 1.5 to 2 metres above the pavement, on a frangible support, and they are especially critical at busy airports to prevent runway incursions.
Q4Can a pilot or driver ask for clearance to pass a no entry sign?
The sign's function is purely prohibitive. It says the route ahead is closed, with no conditional clearance path implied, because the areas it protects carry a level of risk that leaves no room for judgement calls. It reinforces, rather than replaces, any physical barriers, markings or lighting also closing the area.
Q5How are no entry signs used for temporary closures?
Signs marking construction or maintenance closures often use a portable frangible base rather than a cast-in post, so they can be relocated as the closure boundary moves. Permanent no entry locations use the same fixed frangible post foundation as other mandatory signs, and portable units typically rely on retroreflective sheeting or battery-powered LED instead of a permanent cable run.
Q6What size is a no entry sign?
Face width is roughly 1.46 m for aerodrome reference code 1 to 2 up to about 1.94 m for code 3 to 4, with a face height of 0.3 to 0.6 m. Legend height is 200, 300 or 400 mm according to the reference code (1-2, 3 or 4), not a viewing-distance choice.
Q7How is an illuminated no entry sign powered?
An illuminated no entry sign is wired onto the constant current series circuit for its section of the airfield and fed through its own isolating transformer rather than directly from the loop. The Constant Current Regulator (CCR) holds the loop at a fixed current (up to 6.6 A, with steps of 2.8, 3.4, 4.1, 5.2 and 6.6 A) and the ALCMS selects the brightness step, so the sign burns at the same intensity as the other fixtures on that loop. The non-illuminated variant is a passive retroreflective panel with no electrical supply.
Q8Which standards apply to no entry signs?
ICAO Annex 14 covers colours, dimensions and placement, and FAA AC 150/5340-18 covers siting, design and colour convention for airport signs. FAA AC 150/5345-44 is the equipment specification for the sign unit itself, ASTM D4956 sets retroreflective sheeting performance, and IEC 60598 covers luminaire requirements for illuminated signs.
Q9What are the photometric requirements for a no entry sign?
Typical values are a red background luminance of at least 30 cd/m² average on the illuminated variant (uniformity no worse than 10:1) and white legend or symbol luminance of at least 150 cd/m², with a 5:1 to 10:1 contrast ratio. For the non-illuminated variant the retroreflective coefficient should be at least 50 cd/lux/m² for white and 15 cd/lux/m² for red per ASTM D4956 Class 1 or 2.
Q10How often should no entry signs be inspected and maintained?
Typical intervals are quarterly for cleaning dirt, de-icing fluid residue and rubber deposits off the sign face, and annual for retroreflectivity measurement, illumination testing, frangible coupling inspection, seal and cable gland checks, and insulation resistance (megger) testing. Retroreflective sheeting is usually budgeted for replacement every 5 to 7 years.
Q11What are the common field issues with no entry signs?
Four issues recur: retroreflective sheeting degradation from UV, weathering and abrasion (replacement is typically due every 5 to 7 years); failure of the internal LED illumination, which cuts night visibility; frangible support fatigue, as breakaway couplings turn brittle with weather and vibration; and moisture ingress through damaged seals or cable glands, which causes corrosion and electrical faults. Routine seal checks and desiccants are recommended.
Related Components
Go Beyond the Component. Understand the Complete AGL System.
You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.
Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.
Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.
Your next step in AGL starts here.
Need expert advice on no entry sign selection or placement?
Precision AGL Academy provides guidance on sign design, illumination, and compliance with ICAO and FAA requirements for access restriction signage.
Follow the Academy
Important Notice, Disclaimer & Limitation of Liability
Please read before relying on any content on this page.
- Purpose and intended users. This page on No Entry Sign is an independent educational and informational reference for competent, suitably trained and authorised airfield ground lighting (AGL) and aerodrome electrical personnel. It is not professional engineering, legal or regulatory advice, and using it does not create any professional or client relationship.
- Safety. Work on series circuits, constant current regulators (CCRs), isolating transformers, cables, connectors and lighting equipment can be fatal. Always apply the aerodrome’s permit-to-work and isolation/LOTO procedures, prove dead, use correctly rated instruments and PPE, and follow the manufacturer’s instructions. Nothing here authorises work on live equipment or the bypassing of any safety device or interlock.
- Aviation operations. Nothing here authorises installation, modification, energisation, adjustment, return to service, a change of operating category (CAT I/II/III), a NOTAM or any aerodrome certification or approval decision. These rest with the aerodrome operator, the air navigation service provider and the competent regulator.
- Specifications, ratings and typical values. Descriptions, parameters, ratings, dimensions, photometric values, wattages, service lives, maintenance tasks and intervals, failure modes, certifications (for example CE, FCC, UL or IEC marks) and part or type designations are general, typical and indicative. They may not match any particular product, make, model or version, and they are not a datasheet, design, specification, selection, sizing, procurement or acceptance criterion. The manufacturer’s current documents, the approved design and the project specification prevail.
- Standards and regulations. References to ICAO, FAA, IEC, IEEE, ISO, BIS, DGCA and other standards are paraphrased summaries for orientation only. They may be incomplete or out of date, and standards are revised from time to time. Consult the current official editions. Following this content does not guarantee compliance with any law, standard or regulatory approval, and the regulator’s requirements always prevail.
- No warranty. Content is provided “as is” and “as available”, without warranty of any kind, express or implied, including accuracy, completeness, currency or fitness for a particular purpose. Real installations differ in design, equipment make and model, age and condition.
- Limitation of liability. To the fullest extent permitted by applicable law, Precision AGL Academy, Precision AGL Solutions and their owners, authors and contributors are not liable for any injury, death, loss, damage, downtime, penalty or regulatory consequence, whether direct or indirect, arising from the use of, reliance on, or inability to use this content. Nothing in this notice excludes or limits any liability that cannot lawfully be excluded or limited.
- Independence, brands and no endorsement. This is an independent publication. It is not affiliated with, sponsored by or endorsed by ICAO, the FAA, the IEC, DGCA, AAI, any airport, regulator, supplier or equipment manufacturer. Third-party names, product designations, standard designations and trademarks (including Megger®, Siemens, Eaton, Crouse-Hinds, ADB SAFEGATE, Fluke, ABB and Honeywell) belong to their respective owners and are used only for identification and description. Mention of a brand, product or supplier is not a recommendation, and we do not sell, supply or quote for any component described.
- Images and third-party content. Images and illustrations are shown to help identify the type of component. They may show products of various manufacturers, may not depict the exact item described, and are not a statement about any product’s quality, approval or performance. Copyright and trademarks in third-party images, logos and photographs belong to their respective owners and are not claimed as ours. If you are a rights holder and want an image removed, replaced or credited, email precisionaglsolutions@gmail.com with the page address and we will act promptly.
- Training and services. Mentions of training, courses, consultation, advice, selection, installation, calibration or other support, including the “Learn…Certify” pathway, describe learning stages and are not an offer, quotation, tender or promise of any result. Contacting us or our replying creates no engagement or duty of care; an engagement exists only under a written agreement. We are not a regulator or certification body, and completing any course or reading this content is not a certification, accreditation or authorisation to work on any aerodrome.
- Copyright, privacy and corrections. © 2026 Precision AGL Academy. All rights reserved. Text, structure, compilations and diagrams may be viewed for personal reference and internal training only; any other copying, republication or commercial use needs our written permission. If you email, telephone or message us, we use your details only to respond and handle your matter, in line with applicable Indian law including the Digital Personal Data Protection Act, 2023; please do not send confidential or security-sensitive information. To display this page your browser requests fonts, icons and images from third-party servers, which receive your IP address and browser details under their own policies. Content is reviewed periodically with no obligation to update. To report an error, safety concern or rights issue, write to precisionaglsolutions@gmail.com.