AGL Component Library By Precision AGL Academy

Bidirectional Runway Centreline Light

A flush‑mounted runway centreline light that emits light in both directions along the runway axis. Provides continuous longitudinal guidance to pilots during take‑off, landing, and roll‑out on runways used from both ends. Features the standard white‑red‑white colour coding to indicate remaining runway distance.

Bidirectional Runway Centreline Light

Image disclaimer: For identification and illustration only. It may show a product by another manufacturer and may not depict the exact item described; it is not a statement of any product’s quality, approval or performance. Third-party image and trademark rights belong to their owners. See full notice.

Overview

What Is It?

A Bidirectional Runway Centreline Light is an inset light fixture installed along the exact centre of the runway, engineered to project light in two opposite directions along the runway centreline. This design ensures that the light is visible to pilots approaching from either end of the runway, as well as to crews during the landing roll and take‑off run. The colour coding is identical to standard centreline lights: white from the threshold up to 900 m from the runway end, alternating red and white between 900 m and 300 m, and red in the last 300 m. This provides pilots with a clear visual indication of remaining runway length, regardless of the direction of travel.

Purpose

Purpose & Function

The bidirectional design exists because many runways genuinely operate in both directions depending on the day's wind conditions, and a centreline light visible from only one end would leave the opposite-direction traffic without the same precise remaining-distance guidance. By projecting light both ways from a single fixture, the runway gets full centreline tracking and distance-remaining information regardless of which direction is currently active, without needing to install and maintain two separate light strings.

The same white/red-white/red colour progression works from either end because the pattern is symmetric relative to each threshold, meaning a pilot lands or departs and always sees the same meaningful sequence of colour transitions leading toward the runway end they're approaching, no matter which physical direction that happens to be on a given day.

Application

Where Is It Used?

Bidirectional centreline lights are installed on runways that are used for take‑off and landing in both directions (i.e., non‑directional runways). They are common on precision approach runways (CAT I, II, and III) where centreline guidance is required for both approach directions. The lights are spaced at 15‑metre intervals for CAT I runways and 7.5‑metre intervals for CAT II/III runways. They are used in conjunction with bidirectional runway edge lights and, where applicable, with touchdown zone lights that are also bi‑directional. The bidirectional optical design eliminates the need for separate unidirectional fixtures for each runway end, simplifying installation and maintenance.

Placement

Installation & Location

Bidirectional centreline lights are set flush into the runway pavement along the physical centreline, tied into the runway centreline survey the same way as unidirectional fixtures, at 15 m intervals for CAT I runways and 7.5 m intervals through the CAT II/III zone. Because each fixture projects light both ways along the runway, only a single row of lights is needed regardless of which direction is in use, simplifying the setting-out compared with runways that would otherwise need separate fixtures or optics for each landing direction. Each unit seats into an inset base can sealed against water and jet-blast erosion, fed by cable run in pavement ducting back to its isolating transformer, with installation following the same colour-zone layout (white body, red/white transition, solid red) used for the equivalent unidirectional centreline lighting.

Function

How Does It Work?

Each bidirectional centreline light is powered from the constant current series circuit via an isolating transformer. The fixture contains two optical systems – one facing each direction – or a single bi‑directional optical assembly (often using a prism or dual‑reflector design) that splits the light output into two equal beams along the runway centreline. Each beam typically has a narrow vertical spread (4°) and a horizontal spread (6°) to ensure visibility over a long distance. The colour transition is achieved using dichroic filters or coloured lenses that are selected based on the fixture's position along the runway. The intensity is controlled by the CCR's current steps, with higher intensities (up to 6.6 A) used during low‑visibility operations. The bidirectional nature is particularly useful during runway changes, as the same fixtures provide guidance for both approach directions without requiring reconfiguration.

Architecture

System Architecture & Control Logic

Bidirectional centreline lights are not individually addressable — control is exercised at the loop level through the constant current series circuit. An Airfield Lighting Control and Monitoring System (ALCMS), operated by the tower or an automated visibility-linked routine, selects the required brightness step based on prevailing RVR, ATC instruction, or (at smaller aerodromes) pilot-controlled lighting input. This command is passed to the CCR, which regulates the entire loop to the corresponding fixed current (one of 5 steps between 2.8A and 6.6A). Every fixture on that loop, via its own isolating transformer, draws from the same current and burns at the same intensity simultaneously in both directions — there is no way to intensify or dim one beam of a fixture, or one fixture, independently of the rest of the circuit. Colour is fixed at manufacture by the dichroic filter or lens selected for each fixture's position, so it is set by physical location on the loop rather than by any command from the ALCMS. Fault detection remains loop-based: the CCR monitors loop voltage against the commanded current, and a voltage rise signals increased circuit impedance — typically an open-circuit lamp or a failed isolating transformer — reported to the ALCMS as a loop fault rather than pinpointed to an exact fixture or beam direction without further sectionalised testing.

ALCMS → CCR → Series Circuit Loop → Isolating Transformer → Bidirectional Fixture (with loop-level feedback)

AIRFIELD LIGHTING CONTROL SYSTEM (ALCMS) Selects brightness step (RVR / ATC / PCL) CONSTANT CURRENT REGULATOR Converts step command to fixed current SERIES CIRCUIT LOOP Same current for every fixture — no individual control ISOLATING TRANSFORMER (PER FIXTURE) Taps fixed loop current to fixture secondary BIDIRECTIONAL FIXTURE Splits current into two fixed-colour beams LOOP-LEVEL CONTROL — NOT PER-FIXTURE Both beam directions switch and dim together Colour is fixed by position, not by command LOOP FEEDBACK CCR tracks loop voltage against commanded current Voltage rise flags an open circuit or failed transformer
System Integration

Circuit & Beam Overview

CCR Series circuit, up to 6.6 A Isolating Transformer Single fixture feed Bi‑Directional Fixture dual‑reflector / prism Beam A Toward Threshold 1 Beam B Toward Threshold 2 Pilot End A Pilot End B One Fixture, Two Live Beams Same colour transition visible from either end, simultaneously

A single isolating transformer still feeds one fixture, but that fixture splits its output into two opposing beams rather than one — the same current draw as a unidirectional fixture now serves pilots at both ends of the runway at once, avoiding the need for a second fixture per position.

Construction

Physical Construction

The fixture uses a die-cast aluminium body, precision-machined and anodised or powder-coated for corrosion resistance, set flush into an L-867 base can (fixture qualified under the L-850 series, FAA runway centreline light designation) recessed into the runway pavement. Because the unit must project light in two opposite directions along the centreline, it incorporates two separate lamp/LED and prism assemblies (or a single bi-lobed reflector arrangement) arranged back-to-back within a common housing, each independently aimed along the runway axis. The optical elements sit beneath a toughened borosilicate glass or polycarbonate top lens, load-rated for aircraft wheel loading and gasket-sealed with an O-ring to achieve an IP67/IP68 rating. Colour changes along the fixture's length are achieved with coloured filter segments or dual-colour LED arrays (white/red) built into each optical path rather than by physically relocating fixtures. Internal wiring from both optical assemblies terminates at sealed L-823 primary connectors mating to the secondary leads of a nearby isolating transformer housed in its own base can, with stainless-steel fasteners and a drainage channel provided to keep the base can free of standing water.

Specification

Technical Parameters

ParameterTypical Value
Light SourceLED array (or 45W / 65W halogen)
Colour CodingWhite (first 900m from each threshold), Alternating Red/White (next 600m), Red (last 300m)
Intensity (Max)Up to 10,000 cd per beam (LED) / 8,000 cd (halogen) at 6.6A
Intensity Steps5‑step (2.8A – 6.6A) CCR controlled
Spacing15m (CAT I) / 7.5m (CAT II/III)
Beam PatternBi‑directional (4° vertical x 6° horizontal each beam)
Mounting TypeFlush‑mounted (inset) in pavement
Load Capacity100,000 kg (220,000 lbs) wheel load
Isolating Transformer45W / 65W (6.6A series circuit)
Protection ClassIP67 / IP68 (submersible, pressure‑vented)
Power Supply

Electrical Requirements

RequirementTypical Value
Circuit TypeSeries circuit, constant current (CCR fed)
Rated Series Current6.6A (5-step: 2.8A / 3.4A / 4.1A / 5.2A / 6.6A)
IsolationVia dedicated isolating transformer (45W/65W) per unit
Transformer SecondaryMatched to fixture wattage; sized to series circuit rating
Cable TypeL-824 single-conductor, direct-burial rated, 5kV or 600V per circuit design
ConnectorL-823 primary connector, submersible-rated splice
Insulation Resistance≥ 50 MΩ (megger test, cable-to-ground)
Earthing/GroundingFixture body and base can bonded to airfield earth grid
Fault ProtectionCCR-level ground fault and open-circuit detection
Power SourceCCR output, regulated per ICAO/FAA intensity step schedule
Optical Performance

Photometric Requirements

ParameterTypical Value
Main Beam Intensity (White)≥ 6,500 cd per beam (LED), up to 10,000 cd at full intensity
Main Beam Intensity (Red)≥ 5,000 cd per beam, up to 8,000 cd at full intensity (last 300m zone)
Beam PatternBi-directional, 4° vertical × 6° horizontal per beam (fore and aft)
Colour Coding ZonesWhite (first 900m from each threshold), alternating red/white (next 600m), red (last 300m)
Vertical Beam Spread± 2° about the fixture's set elevation, symmetric fore/aft
Isocandela DistributionPer ICAO Annex 14 Attachment A / FAA AC 150/5340-30 figures
Chromaticity (White)Within ICAO Annex 14 white boundary (CIE coordinates)
Chromaticity (Red)Within ICAO Annex 14 red boundary (CIE coordinates)
Intensity Tolerance± 25% of rated value at each CCR step (field measurement)
Maintenance Factor≥ 50% of new-fixture intensity before lens/LED replacement is due
Test MethodMobile photometric van/goniophotometer or fixed test bench per fixture
Compliance

Applicable Standards

ICAO Annex 14

Centreline light colour, spacing, and photometric requirements for bidirectional fixtures

FAA AC 150/5345-46

General FAA fixture specification; covers the L-850 series runway centreline light (bidirectional variants)

IEC 61822

Constant current regulator (CCR) requirements for the series circuit feeding the fixture

IEC TS 61827

Characteristics of inset and elevated luminaires used on aerodromes, incl. bidirectional centreline light performance

Prerequisites

Installation Requirements

Base Can Setting
Civil

Set the L-867 base can flush and level within the runway pavement tolerance before fixture installation (fixture qualified under the L-850 series), providing a drainage channel to keep it free of standing water.

Duct & Cable Route
Electrical

Lay the series circuit duct/cable route to design depth, avoiding sharp bends that could stress the L-823 connectors at final termination.

Dual L-823 Connector Termination
Electrical

Terminate and seal both optical assemblies' primary connectors, mating each to the secondary leads of the nearby isolating transformer housed in its own base can.

Isolating Transformer Matching
Electrical

Confirm the isolating transformer wattage and ratio match the fixture and the series circuit's rated current step before connection.

Dual-Direction Aim Setting
Mechanical

Aim each back-to-back optical assembly independently along the runway axis, confirming both directions present the correct beam before backfill.

Colour Segment Verification
Mechanical

Confirm the coloured filter segments or dual-colour LED arrays fitted match the fixture's position within the runway's zone-based colour-coding scheme.

Flush-Mount Level Setting
Mechanical

Set the fixture flush with the pavement surface within tolerance for both photometric performance and wheel-load safety.

Pre-Energisation Sign-off
Documentation

Record base can position, cable routing, colour segment fitment, and aim settings as-built before backfill.

Verification

Testing & Commissioning

Insulation Resistance (Megger) Test
Pre-Energisation

Megger-test the isolating transformer and series loop before energisation, confirming insulation resistance clears the acceptable minimum.

Loop Continuity & Resistance Test
Pre-Energisation

Verify series loop continuity end to end and record total loop resistance before the circuit is first energised.

Bidirectional Beam Verification
Energisation

Confirm the fixture presents its correct colour and intensity to observers approaching from both runway ends, not just the direction faced during installation.

Colour Transition Zone Check
Energisation

Confirm the fixture's colour (white, alternating red/white, or red) matches its position within the runway's zone-based colour-coding scheme.

Flush-Mount Tolerance Check
Final Acceptance

Confirm the inset fixture sits flush with the pavement surface within tolerance for both photometric performance and wheel-load safety.

Photometric Commissioning Test
Final Acceptance

Measure beam intensity and colour in both directions with a calibrated photometer against ICAO/FAA commissioning tolerances.

Documentation & As-Built Sign-off
Final Acceptance

Record insulation, loop resistance, bidirectional beam, and photometric readings in the commissioning dossier for handover.

Upkeep

Inspection & Maintenance

Bi-directional Alignment Check
Semi-annual

Verify both beams remain correctly aligned along the runway centreline, since drift on one side can go unnoticed from the other approach.

Bi-directional Photometric Check
Annual

Measure luminous intensity from both directions and compare against rated values to catch uneven output early.

Colour Filter Inspection
Semi-annual

Check colour filters on both sides for fading or degradation, since exposure can differ between the two faces.

Seal & Moisture Ingress Check
Annual

Inspect seals on both optical cavities, since moisture affecting one side doesn't always show in the other.

Field Notes

Common Field Issues

Optical Misalignment of Bidirectional Beams

Because the fixture has two optical paths, any slight misalignment during installation or after pavement settlement can cause one beam to deviate, reducing visibility from one direction. Regular alignment checks using a precision goniophotometer or digital level are essential to maintain both beams within the required tolerance (±0.5°).

Uneven Luminous Intensity Between the Two Beams

Dirt, moisture, or aging of optical components can cause unequal light output between the two beams. This can be particularly confusing for pilots as one direction may appear dimmer. Routine photometric testing of each beam individually is recommended, along with cleaning and replacement of prisms or lenses as needed.

Colour Filter Degradation on Both Sides

Bidirectional fixtures have colour filters for both directions, which are subjected to UV and thermal stress. Over time, the red and white filters can fade or shift, compromising the colour coding. Regular filter replacement and photometric colour measurements are required to maintain the integrity of the colour‑distance indication.

Moisture Ingress Affecting Both Optical Cavities

Bidirectional fixtures have two separate optical cavities or a shared cavity with two optical windows. A single point of ingress (e.g., a failed O‑ring or pressure vent) can affect both beams. Routine seal inspection and pressure‑vent maintenance are critical to prevent condensation and corrosion inside the fixture.

Field Notes

Troubleshooting Guide

One Beam Direction Dim or Not Visible
Likely Cause
Optical misalignment of one of the two beam paths, from installation error or pavement settlement, has pushed that beam outside its required tolerance.
Diagnostic Steps
Check both beam alignments with a precision goniophotometer or digital level against the ±0.5° tolerance.
Corrective Action
Re-align the affected beam to bring it within tolerance, and re-survey after any pavement work near the fixture.
Unequal Intensity Between the Two Beams
Likely Cause
Dirt, moisture, or aging optical components affecting one beam's prism or lens more than the other.
Diagnostic Steps
Take independent photometric readings for each beam direction and compare against each other and against spec.
Corrective Action
Clean or replace the prism/lens on the underperforming beam, and re-verify both beams match within tolerance.
Colour Fade Differing Between Red and White Sides
Likely Cause
UV and thermal degradation of the colour filters, progressing unevenly between the two directional filters.
Diagnostic Steps
Run photometric colour measurements on both the red and white sides and compare against the colour-distance indication spec.
Corrective Action
Replace the faded filter(s) and re-verify colour-distance indication integrity on both sides.
Both Beams Affected by Moisture or Condensation
Likely Cause
A single point of ingress, such as a failed O-ring or blocked pressure vent, affecting the shared or dual optical cavity.
Diagnostic Steps
Inspect the O-ring seal and pressure vent for damage or blockage; check for internal condensation or corrosion.
Corrective Action
Replace the failed seal and clear or replace the pressure vent, then dry the cavity and confirm no further condensation before re-sealing.
Reliability

Failure Modes & Root Causes

Open Circuit / Failed Isolating Transformer Detected Only at Loop Level
High Severity
Root Cause
LED array or transformer failure at an individual fixture, which the CCR's loop-level voltage monitoring flags as a voltage rise without identifying which fixture on the loop has failed.
Effect
A dark fixture on the centreline is confirmed to exist somewhere on the loop, but pinpointing which one requires field testing rather than a control-system readout, since control and colour are managed at loop level rather than per fixture.
Detection Method
Loop voltage trend review against the CCR's baseline, followed by a sectionalised field walk or fixture-by-fixture continuity check to localise the fault.
Uneven Wear Between the Red and White Optical Halves
Medium Severity
Root Cause
One direction's optical half seeing disproportionately more landing or take-off traffic than the other, depending on prevailing wind and runway usage patterns, ageing that half's lens and LEDs faster.
Effect
One colour direction shows earlier photometric degradation than the other on the same physical fixture, an asymmetric wear pattern this bidirectional design is specifically exposed to.
Detection Method
Photometric testing of both optical halves independently rather than assuming symmetric condition from a single-direction test.
Bidirectional Lens / Prism Misalignment
Medium Severity
Root Cause
Settlement or an impact event shifting the fixture's dual-direction optic out of its commissioned alignment.
Effect
Beam confinement degrades on one or both directions, weakening the centreline cue for approach or take-off traffic from that end.
Detection Method
Fixture aim and orientation check against the runway centreline survey for both directions during scheduled inspection.
LED Array Failure
High Severity
Root Cause
Thermal cycling or a manufacturing defect in the LED array serving either optical half.
Effect
That fixture goes dark for one or both directions, breaking the continuous centreline reference at that point on the runway.
Detection Method
Test activation from both directions, and loop-resistance testing to help localise a suspected fixture.
Series Circuit Insulation Breakdown at Close Fixture Spacing
Medium Severity
Root Cause
Moisture ingress or cable damage along the circuit, more consequential here given the tight 7.5–15 m fixture spacing on CAT I/II/III bidirectional runs.
Effect
Intermittent operation or a partial ground fault on the circuit segment, potentially affecting several closely spaced fixtures at once.
Detection Method
Insulation resistance (megger) testing of the circuit segment during scheduled maintenance.
Precautions

Safety & Operational Notes

Series Circuit Isolation
Electrical Safety

Centreline light circuits run on a constant-current series loop that can carry several kV. De-energise and lock out the CCR, then verify zero energy at the fixture before opening the inset housing or handling cable connectors.

Active Runway Work Coordination
Operational

The fixture sits directly on the landing/take-off path and load-bearing surface; obtain ATC/airside coordination and a NOTAM where the fixture will be dark or out of tolerance, and never work on it with the runway active without an approved closure or protected work window.

Aircraft Wheel-Load Integrity
Mechanical

The fixture and its inset housing are directly trafficked by aircraft tyres; confirm the top plate, lens, and housing seat flush with the pavement surface and are rated for the design wheel load before reinstating, since a proud or cracked fixture becomes an FOD and load-bearing hazard.

FOD Control at the Fixture
Operational

Keep tools, fasteners, and removed gaskets accounted for at all times when the housing is open, and secure or remove any loose material before reinstating the fixture, to prevent foreign object debris on the runway.

Hot Lamp / Housing Contact
Personnel Safety

Allow the fixture housing and lamp/LED module to cool before handling after an active period; incandescent units in particular retain significant heat and can cause burns during lens or lamp replacement.

Insulation Test Before Re-Energisation
Electrical Safety

After any cable, connector, or transformer work, megger test the affected series loop before restoring power, since a residual fault at re-energisation can trip the CCR or damage healthy fixtures on the same circuit.

PPE & Grounding
Personnel Safety

Use insulated tools and appropriate PPE when working on series-circuit connections, and confirm the fixture and housing are bonded/grounded per the electrical design before reconnecting the loop.

Restore to Compliant State
Compliance

Do not leave a fixture out of aim tolerance, at reduced intensity, or with the wrong colour segment showing after maintenance; verify photometric, positional, and colour-zone conformance before closing out the work and cancelling the associated NOTAM.

Field Insight

Engineering & Expert Notes

Colour Changeover Position Needs Periodic Re-Verification
Compliance

The point along the runway where centreline lighting transitions from white to red/white to red is a defined design distance from the runway end; confirm this changeover position is still correct after any relocation, repaving, or fixture replacement rather than assuming the original layout persists.

Colour Consistency Must Hold in Both Directions of Travel
Verification

A bidirectional fixture's two colour outputs can age or drift at different rates from each other; verify both directions independently during testing rather than confirming one direction and assuming the other matches.

Wheel-Load Integrity Is More Critical Here Than on Elevated Fixtures
Mechanical

Bidirectional centreline fixtures are inset and take direct, repeated wheel loading along the most heavily trafficked line on the runway; prioritise housing and lens integrity checks on these fixtures over a uniform inspection interval applied runway-wide.

Dual-Colour LED Modules Can Age Asymmetrically
Reliability

Where a fixture uses separate LED elements for each colour, one colour's elements can lumen-depreciate faster than the other depending on drive current and duty cycle, gradually shifting the relative brightness balance between directions even though each colour individually still passes minimum output.

Inset Housing Seal Integrity Matters More at High-Traffic Centreline Positions
Durability

Centreline positions see concentrated wheel traffic and de-icing fluid exposure; seal degradation here has a shorter runway to failure than at lower-traffic inset positions. Prioritise these fixtures in gasket and seal inspection scheduling.

Verify From an Approaching Pilot's Actual Viewing Angle, Not Just Overhead
Verification

A fixture's colour and brightness can measure correctly on axis while looking noticeably different from the shallow viewing angle of an approaching or departing pilot. Where practical, verify from a representative low-angle viewpoint rather than relying solely on direct overhead or bench measurement.

Quick Answers

Frequently Asked Questions

Short answers about the Bidirectional Runway Centreline Light: what it is, how it works, typical specifications, standards, maintenance and common faults.

Q1What is a Bidirectional Runway Centreline Light?

A Bidirectional Runway Centreline Light is an inset light fixture installed along the exact centre of the runway, engineered to project light in two opposite directions along the runway centreline. This design ensures that the light is visible to pilots approaching from either end of the runway, as well as to crews during the landing roll and take‑off run.

Q2What is the purpose of a Bidirectional Runway Centreline Light?

The bidirectional design exists because many runways genuinely operate in both directions depending on the day's wind conditions, and a centreline light visible from only one end would leave the opposite-direction traffic without the same precise remaining-distance guidance. By projecting light both ways from a single fixture, the runway gets full centreline tracking and distance-remaining information regardless of which direction is currently active, without needing to install and maintain two separate light strings.

Q3Where is a Bidirectional Runway Centreline Light used and installed?

Bidirectional centreline lights are installed on runways that are used for take‑off and landing in both directions (i.e., non‑directional runways). They are common on precision approach runways (CAT I, II, and III) where centreline guidance is required for both approach directions. The lights are spaced at 15‑metre intervals for CAT I runways and 7.5‑metre intervals for CAT II/III runways. They are used in conjunction with bidirectional runway edge lights and, where applicable, with touchdown zone lights that are also bi‑directional. The bidirectional optical design eliminates the need for separate unidirectional fixtures for each runway end, simplifying installation and maintenance.

Q4How does a Bidirectional Runway Centreline Light work?

Each bidirectional centreline light is powered from the constant current series circuit via an isolating transformer. The fixture contains two optical systems – one facing each direction – or a single bi‑directional optical assembly (often using a prism or dual‑reflector design) that splits the light output into two equal beams along the runway centreline. Each beam typically has a narrow vertical spread (4°) and a horizontal spread (6°) to ensure visibility over a long distance.

Q5What are the typical technical parameters of a Bidirectional Runway Centreline Light?

Typical values are — Light Source: LED array (or 45W / 65W halogen); Colour Coding: White (first 900m from each threshold), Alternating Red/White (next 600m), Red (last 300m); Intensity (Max): Up to 10,000 cd per beam (LED) / 8,000 cd (halogen) at 6.6A; Intensity Steps: 5‑step (2.8A – 6.6A) CCR controlled; Spacing: 15m (CAT I) / 7.5m (CAT II/III); Beam Pattern: Bi‑directional (4° vertical x 6° horizontal each beam); Mounting Type: Flush‑mounted (inset) in pavement; Load Capacity: 100,000 kg (220,000 lbs) wheel load; Isolating Transformer: 45W / 65W (6.6A series circuit); Protection Class: IP67 / IP68 (submersible, pressure‑vented).

Q6What are the electrical requirements for a Bidirectional Runway Centreline Light?

Typical requirements are — Circuit Type: Series circuit, constant current (CCR fed); Rated Series Current: 6.6A (5-step: 2.8A / 3.4A / 4.1A / 5.2A / 6.6A); Isolation: Via dedicated isolating transformer (45W/65W) per unit; Transformer Secondary: Matched to fixture wattage; sized to series circuit rating; Cable Type: L-824 single-conductor, direct-burial rated, 5kV or 600V per circuit design; Connector: L-823 primary connector, submersible-rated splice; Insulation Resistance: ≥ 50 MΩ (megger test, cable-to-ground); Earthing/Grounding: Fixture body and base can bonded to airfield earth grid; Fault Protection: CCR-level ground fault and open-circuit detection.

Q7What photometric requirements apply to a Bidirectional Runway Centreline Light?

Typical requirements are — Main Beam Intensity (White): ≥ 6,500 cd per beam (LED), up to 10,000 cd at full intensity; Main Beam Intensity (Red): ≥ 5,000 cd per beam, up to 8,000 cd at full intensity (last 300m zone); Beam Pattern: Bi-directional, 4° vertical × 6° horizontal per beam (fore and aft); Colour Coding Zones: White (first 900m from each threshold), alternating red/white (next 600m), red (last 300m); Vertical Beam Spread: ± 2° about the fixture's set elevation, symmetric fore/aft; Isocandela Distribution: Per ICAO Annex 14 Attachment A / FAA AC 150/5340-30 figures; Chromaticity (White): Within ICAO Annex 14 white boundary (CIE coordinates).

Q8Which standards apply to a Bidirectional Runway Centreline Light?

The main references are ICAO Annex 14 — Centreline light colour, spacing, and photometric requirements for bidirectional fixtures; FAA AC 150/5345-46 — General FAA fixture specification; covers the L-850 series runway centreline light (bidirectional variants); IEC 61822 — Constant current regulator (CCR) requirements for the series circuit feeding the fixture; IEC TS 61827 — Characteristics of inset and elevated luminaires used on aerodromes, incl. bidirectional centreline light performance. Always verify the current edition and your aerodrome's approved requirements.

Q9How often should a Bidirectional Runway Centreline Light be inspected and maintained?

Typical maintenance tasks and intervals are: Bi-directional Alignment Check (semi-annual); Bi-directional Photometric Check (annual); Colour Filter Inspection (semi-annual); Seal & Moisture Ingress Check (annual). Your airport's approved maintenance programme takes precedence.

Q10How do I troubleshoot common Bidirectional Runway Centreline Light faults?

Common symptoms covered are: One Beam Direction Dim or Not Visible; Unequal Intensity Between the Two Beams; Colour Fade Differing Between Red and White Sides; Both Beams Affected by Moisture or Condensation. For example, for "One Beam Direction Dim or Not Visible": Likely Cause: Optical misalignment of one of the two beam paths, from installation error or pavement settlement, has pushed that beam outside its required tolerance. Diagnostic Steps: Check both beam alignments with a precision goniophotometer or digital level against the ±0.5° tolerance. Corrective Action: Re-align the affected beam to bring it within tolerance, and re-survey after any pavement work near the fixture.

Go Further

Go Beyond the Component. Understand the Complete AGL System.

You have explored the component. Now understand how it works within the complete Airfield Ground Lighting system.

Learn AGL from fundamentals to design, installation, testing, photometry, commissioning, maintenance and troubleshooting through structured technical training at Precision AGL Academy.

Build practical knowledge. Understand the circuit. Read the standards. Troubleshoot with confidence.

Your next step in AGL starts here.

The Learning Pathway
Learn Understand Design Test Maintain Document Apply Certify

Need expert guidance on bidirectional centreline light selection or installation?

Precision AGL Academy provides advice on optical alignment, beam balance, and field testing of bidirectional AGL fixtures for dual‑direction runways.