In 2020, I entered the manufacturing domain of CTC Make AGL Isolating Transformers with a clear objective: improve the reliability, safety, and lifecycle performance of airfield lighting systems.

Today, CTC Make AGL Isolating Transformers and ESSNA Connectors — Plug, Receptacle & Inline Connectors — are AAI-approved products, widely used in airport projects across India and overseas. This article is a practical account of that journey — the engineering decisions, the testing discipline, and the field lessons that shaped a component that runway and taxiway safety depends on every single night.

Disclosure: I work with Creative Trading Co. (CTC), the manufacturer of the products described here. This is a personal account of our development work, not independent product testing or an endorsement.

In This Article
Key Takeaway

Reliability in AGL manufacturing is not a marketing claim — it is engineered, batch by batch, through precision winding, moisture-resistant construction, independent lab validation, and disciplined quality control, from prototype to more than 15,000 units in the field.

01

Setting the Context

In a 6.6 A series circuit, the isolating transformer ensures electrical isolation between the primary circuit and the secondary lamp circuit while maintaining continuity across the entire string of fittings. Its reliability directly impacts runway and taxiway safety — a single failed unit (for example, one with an open primary) can affect the whole circuit, not only the fittings near it.

That single fact — one transformer, one point of failure, an entire circuit at stake — is what shaped every manufacturing decision described in this article.

02

Engineering Upgrade — 360-Degree Machine Winding

One of the key technical improvements introduced during development was 360-degree machine winding of transformer coils. Instead of manual or semi-automatic winding, we adopted precision-controlled machine winding to achieve:

This directly enhanced efficiency, reduced losses, and improved long-term reliability. The objective was not simply to automate manufacturing, but to improve consistency and repeatability in a safety-critical AGL component.

03

Shift to Injection Molding Construction

We developed a fully injection-molded transformer body built to the requirements of FAA AC 150/5345-47, issued by the Federal Aviation Administration (this describes design and test to the specification and is not, by itself, FAA equipment certification under AC 150/5345-53). Injection molding reduced the inconsistencies commonly seen in conventional potting methods, and the advantages achieved included:

Uniform InsulationConsistent thickness across every unit
Mechanical StrengthHigh resistance to handling & installation stress
Moisture ResistanceImproved sealing for underground conditions
Dimensional ConsistencyBetter fit and repeatability batch to batch
Reliability TargetAimed at fewer field failures in underground installs

For underground airfield lighting applications, where equipment can be exposed to moisture and demanding environmental conditions, consistency in construction is particularly important.

04

Development of CTC ESSNA Connectors

Parallel to transformer development, we designed CTC Make ESSNA Connectors — Plug, Receptacle & Inline Connectors — as per FAA AC 150/5345-26. The main focus areas included:

The connectors are compatible with FAA-style L-823 configurations used globally in airfield lighting systems. Their development complemented the isolating transformer programme by addressing another critical part of the AGL series circuit.

05

Government MSME Testing — Chennai

To ensure independent validation, we tested all CTC Make AGL Isolating Transformers and ESSNA Connectors at a Government MSME Testing Laboratory in Chennai. Testing covered dielectric withstand, insulation resistance, temperature rise, load testing, and mechanical and sealing checks.

Independent testing was an important part of the development journey — it provided an additional level of technical verification beyond internal manufacturing quality controls.

06

Nationwide Development Journey

Building the right ecosystem for CTC manufacturing and testing meant travelling extensively — for selecting high-precision testing instruments, evaluating advanced winding and molding machinery, developing vendors, and validating processes.

Chennai
Bangalore
Ahmedabad
Mumbai
Pune

We invested in high-tech machinery for manufacturing, ensuring automation, repeatability, and scalable production capacity. Building the manufacturing ecosystem required not only technical decisions but also coordination between machinery suppliers, testing facilities, vendors, and production teams.

07

Manufacturing Scale and Quality Control

From prototype to mass production, we implemented a structured quality-control process:

The combination of 360-degree machine winding and injection molding has enabled consistent electrical and mechanical performance across batches. For a critical airport component, manufacturing consistency is essential because reliability must be maintained from one production batch to the next.

08

Market Acceptance and Performance

Today, our brand has sold more than 15,000 Nos. AGL Isolating Transformers in India and international markets. This growth reflects both technical strength and market trust.

15,000+
Units sold in India & overseas
5
Cities in the development journey
2020
Manufacturing programme began
AAI
Approved product status

Feedback received from the field so far has been encouraging on moisture-related failures, temperature behaviour and maintenance downtime; it is informal and is not a measured failure-rate study. The journey from product development to wider field adoption has provided valuable feedback about how manufacturing decisions translate into actual airport performance.

09

Personal Growth and Technical Leadership

This journey strengthened my expertise in FAA specification interpretation, manufacturing process engineering, high-voltage insulation systems, testing instrumentation selection, and cross-functional coordination.

From concept to AAI approval and large-scale market acceptance, I have been actively involved in building a strong and reliable Indian brand for AGL components. The experience has demonstrated that successful aviation manufacturing requires a combination of technical knowledge, process discipline, testing capability, field understanding, and long-term commitment.

10

Future Vision

The focus going forward remains on:

Conclusion

Developing CTC Make AGL Isolating Transformers and ESSNA Connectors has been a technically demanding and professionally rewarding journey centred on reliability, safety, and long-term performance in critical airfield lighting systems.

From 360-degree machine winding to injection-molded construction, independent MSME testing, and a nationwide vendor-development effort, every decision traced back to one requirement: the component has to work, every night, on every runway it is installed on.

"

In manufacturing for aviation, reliability is not optional — it is engineered.

11

Frequently Asked Questions

Is this article an independent product review?

No. The author works with Creative Trading Co. (CTC), the manufacturer of the products described, and the article is a personal account of CTC's development work, not independent product testing or an endorsement. The field feedback it mentions is informal and is not a measured failure-rate study.

What does an isolating transformer do in a 6.6 A AGL series circuit?

It provides electrical isolation between the primary circuit and the secondary lamp circuit while maintaining continuity across the entire string of fittings. Its reliability directly affects runway and taxiway safety, because a single failed unit, for example one with an open primary, can affect the whole circuit and not only the fittings near it.

What is 360-degree machine winding and why was it adopted?

It is precision-controlled machine winding of transformer coils, used instead of manual or semi-automatic winding. It aims to give uniform turn distribution, better coil compactness, fewer voids between turns, improved magnetic coupling and stable electrical performance, with the goal of consistency and repeatability in a safety-critical AGL component.

Why use an injection-molded transformer body instead of conventional potting?

The injection-molded body was built to the requirements of FAA AC 150/5345-47 and reduces the inconsistencies commonly seen in conventional potting. The advantages cited are uniform insulation thickness, mechanical strength, improved moisture sealing for underground conditions and dimensional consistency from batch to batch. The article notes that this describes design and test to the specification and is not, by itself, FAA equipment certification under AC 150/5345-53.

Which standard were the CTC ESSNA connectors designed to?

They were designed as per FAA AC 150/5345-26 and are compatible with FAA-style L-823 configurations. The design focus was a robust housing, corrosion-resistant contacts, a waterproof sealing system, strong strain relief and reliable series-circuit continuity.

How were the transformers and connectors independently tested?

They were tested at a Government MSME Testing Laboratory in Chennai. Testing covered dielectric withstand, insulation resistance, temperature rise, load testing, and mechanical and sealing checks, giving an additional level of technical verification beyond internal quality controls.

What quality-control process is used in manufacturing?

The process includes incoming raw material inspection, in-process quality checks, routine and type testing, and batch traceability. Combined with machine winding and injection molding, this is intended to give consistent electrical and mechanical performance from one production batch to the next.