What is reliability in airfield lighting?

The chance that the lights stay lit and correct. A series circuit works like a chain, so reliability comes from fewer weak links and from having a second way to do the job.

RELIABILITY A SERIES CIRCUIT IS A CHAIN, AND A CHAIN IS ONLY AS GOOD AS ITS LINKS EVERY LINK 99.9% RELIABLE · MORE LINKS, LESS RELIABLE chain reliability = link reliability × itself, once per link each link: a cable section, joint or connector 10 LINKS 99.0% RELIABLE 50 LINKS 95.1% RELIABLE 200 LINKS 81.9% RELIABLE ILLUSTRATIVE · NOT MEASURED FIELD DATA HOW RELIABILITY IS BUILT IN 1 FEWER WEAK LINKS fewer joints and connectors 2 ISOLATION TRANSFORMERS lamp failure does not open the loop 3 REDUNDANCY standby CCR, alternate feed, spare supply 4 INTERLEAVING neighbouring lights on different circuits 5 QUALITY AND SEALING potted connectors, drainage, good cable 6 MONITORING alarms and planned maintenance THE METHOD 1 DEFINE WHAT MUST STAY LIT 2 LIST THE CHAIN 3 FIND SINGLE POINTS 4 ADD REDUNDANCY 5 MONITOR AND MAINTAIN 6 LEARN FROM FAILURES SCHEMATIC · ILLUSTRATIVE PROBABILITIES · REAL RELIABILITY COMES FROM FIELD DATA
few links
more links
many links
ways to build reliability in
The Fact Engineering concept

Reliability is the probability that a system does its job, here keeping the right lights lit, for a stated time in stated conditions. In airfield lighting it is designed in through the layout, the equipment and the upkeep, because the lights are a safety aid and cannot be “mostly” on.

1A series circuit is a chain

The same current passes through every element in turn, so a break in any link can darken the whole circuit. Even if each link is very reliable, reliability multiplies down: in the example, links that are each 99.9% reliable give a chain of 99.0% at 10 links but only about 82% at 200. That is why every joint and connector counts, and why fewer of them is better.

FailureEffectDefence
Lamp or LED failsOne light out; the loop keeps running because of the isolation transformerIsolation transformer, replacement lamps
Cable break or bad jointSeries loop opens and the whole circuit can go darkFewer joints, good jointing, routing, spares
Insulation breakdown to earthOften still lit, but a warning that a second fault will cause an outageEarth-fault monitoring, prompt repair
CCR failureThe circuit it feeds goes darkStandby regulator, interleaved circuits
Power lossEvery circuit on that supply goes darkSecondary power source and changeover
Control or communication lossRemote control is lost; the lights themselves keep workingLocal control, resilient communications

2Break the chain, then back it up

The isolation transformer is the key design move: a failed lamp does not open the loop, so one light goes out instead of the circuit. Redundancy then covers what is left, with standby regulators, alternate feeds and a secondary power source. Interleaving puts neighbouring lights on different circuits, so one lost circuit does not leave a dark stretch.

3Build it well and watch it

Most failures start at a joint, connector or seal, so quality cable, potted connectors and good drainage pay back directly. Monitoring through alarms and the control system, plus planned maintenance, finds faults while they are still warnings, and failure records show where the next improvement is worth making.

  1. Define the function. Which lights must stay lit, and for which operations.
  2. List the chain. Supply, regulator, cable, joints, transformers, fixtures, control.
  3. Find single points of failure. Anything whose loss darkens a circuit or an area.
  4. Add redundancy where it counts. Standby equipment, alternate feeds, interleaving.
  5. Monitor and maintain. Alarms, earth-fault checks, inspection and testing.
  6. Learn from failures. Record causes and feed them back into design and spares.
TermMeaning
ReliabilityProbability of working as required for a stated time
Series systemElements in a chain where the failure of one stops the whole
Single point of failureOne element whose loss takes out the function
RedundancyA second means of doing the job, held ready
InterleavingNeighbouring lights fed from different circuits
AvailabilityShare of time the system works, which also depends on repair time
Schematic: the 99.9% link reliability and the 10, 50 and 200 link chains are illustrative probabilities, not field data, and the failure table describes typical effects. Real reliability comes from recorded failures and the airport’s design basis. Secondary power requirements are covered in ICAO Annex 14, Volume I, Chapter 8 and Doc 9157, Part 5; serviceability levels for lighting are in Chapter 10 and Doc 9137, Part 9; confirm against the editions in force. Terms follow IEC 60050-192 (dependability vocabulary).
Entry 24 · Circuit loading Entry 26 · Availability

Frequently Asked Questions

Q1What is reliability in airfield lighting?

The probability that the lighting does its job, staying lit and correct, for a stated time under stated conditions. It is designed in, by the layout, the equipment and the maintenance, not added afterwards.

Q2Why does a series circuit need special care?

The same current flows through every element in turn, so a break anywhere in the loop can darken the whole circuit. Every cable, joint and connector is therefore a link in a chain.

Q3How do isolating transformers help?

Each fixture is fed through its own isolating transformer, so a failed lamp or open secondary does not break the series loop. One light goes out, not the whole circuit.

Q4What is redundancy?

Having a second way to do the job, such as a standby regulator, an alternate feed or a secondary power source, so that one failure does not take the lighting out.

Q5What does interleaving do?

Adjacent lights are put on different circuits, so that losing one circuit leaves every other light lit and the pattern still recognisable instead of leaving a long dark stretch.

Q6How is reliability different from availability?

Reliability is how rarely failures happen. Availability also counts how quickly they are put right, so it depends on repair time as well. Availability is covered in Entry 26.

Precision AGL Academy

See It. Understand It. Then Learn How to Engineer It.

Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.

Build Practical AGL Engineering Skills

Go deeper with structured training from Precision AGL Academy, covering:

AGL Fundamentals Design & Electrical Engineering Approach Lighting Photometry Installation & Commissioning Maintenance & Troubleshooting

Learn how each light, sign and circuit works as part of a complete airport lighting system, not just as an isolated diagram.