What is the magnetic core?

The core is the iron path between the two windings. It carries the flux that moves energy from the loop to the fitting, and it is the only thing that joins them.

LAMINATED STEEL CORE CORE WINDOW FROM LOOP TO LOOP PRIMARY WINDING IN THE LOOP MAGNETIC FLUX CLOSES THROUGH THE CORE SECONDARY WINDING SUPPLIES THE FITTING LIGHT FITTING CORE CARRIES THE FLUXNO ELECTRICAL PATH ACROSS OPEN SECONDARYCORE DRIVEN HARDER · CAN SATURATE DAMAGED COREHEAT · HUM · POOR OUTPUT CORE DETAIL · STACK OF SHEETS EACH SHEET INSULATED ONLY FLUX CROSSES BETWEEN THE WINDINGS NO CONDUCTOR JOINS PRIMARY AND SECONDARY SCHEMATIC · NOT TO SCALE

Swipe to see the full diagram

Normal. The loop current in the primary sets up a changing flux in the core. The core carries that flux round to the secondary, which induces the current that lights the fitting. Only flux crosses; no conductor joins the two windings.

magnetic flux in the core
primary (in the loop)
secondary & fitting
fault
The Fact Circuit practice

The magnetic core is the steel path inside a series isolation transformer that carries the magnetic flux from the primary winding to the secondary winding. Both windings are wound around it. The loop current sets up a changing flux in the core, the core carries it across, and the flux induces the current that supplies the fitting. That flux is the only link between the loop and the fitting: no conductor joins them.

The core is built from thin steel laminations, each insulated from the next, instead of solid iron. A solid block would let eddy currents circulate and waste energy as heat. If the secondary opens, the loop current has nothing to balance it and the core is driven much harder, so it can saturate and the terminals can show a higher, peaky voltage. A damaged core runs hot and hums. It is sealed inside the unit, so a suspect transformer is tested and replaced, not opened. Isolate and prove the circuit dead under site procedures before touching any lead.

Laminated Steel Sheets
Thin sheets stacked into a core, which cuts the circulating eddy currents a solid block would carry.
Insulating Coating
Each sheet is insulated from the next so currents cannot flow between them. See Insulation System.
Legs and Yokes
The windings sit on the legs; the flux closes through the yokes. See Primary Winding and Secondary Winding.
Sealed in the Unit
The core, windings and insulation sit inside the potting and housing, so it cannot be reached in the field. See Transformer Housing.
JobCarries the flux between the two windings
Built fromStacked steel laminations, each insulated
Loses energy asHeat in the core (eddy-current and hysteresis loss)
ReferenceFAA AC 150/5345-47 · ICAO Doc 9157 Part 5
The diagram is a simplified schematic: the windings are drawn on separate legs for clarity, whereas real units usually wind them close together, and real cores differ by manufacturer in shape, material and design. How far an open secondary drives the core and raises the terminal voltage depends on the transformer design, so follow the manufacturer’s data, the design drawings and the applicable specification.
Entry 4 · Secondary winding Entry 6 · Insulation system

Frequently Asked Questions

Q1What is the magnetic core in an AGL isolation transformer?

The iron path inside a series isolation transformer that carries the magnetic flux from the primary winding to the secondary winding. Both windings are wound around it, and it is the only link between them: energy crosses as magnetic flux, with no electrical connection.

Q2Why is the core made of thin laminations instead of solid iron?

A solid block would let circulating eddy currents flow through it and waste energy as heat. Thin steel sheets, each insulated from the next, break up those currents, so the core runs cooler and the transformer is more efficient.

Q3How does the core connect the primary and secondary without an electrical link?

The loop current in the primary winding sets up a changing magnetic flux in the core. That flux passes through the core to the secondary winding and induces the current that supplies the fitting. Only flux crosses; no conductor joins the two windings.

Q4What happens to the core if the secondary goes open-circuit?

With no secondary load to balance the loop current, the core can be driven much harder and may saturate, which is one reason an open secondary can show a higher, peaky voltage at its terminals. How much depends on the transformer design, so follow the manufacturer’s data and treat an open secondary as live.

Q5Can the magnetic core be checked or repaired in the field?

Not directly. The core is sealed inside the potting and housing. A damaged core shows up as heat, hum or poor output, and is found through the normal transformer tests. A transformer with a suspected core fault is replaced under site procedures, not opened up.

Precision AGL Academy

See It. Understand It. Then Learn How to Engineer It.

Recognising an AGL system visually is the first step. The next step is knowing how to design, install, test, commission and maintain them correctly.